54
Display:
Error code:
Description:
Cause and Remedy:
Description:
Cause and Remedy:
Operating Manual
16
Sensor break accumulator sensor, measuring circuit of acculmulator
sensor is open
sensor not connected
sensor defect
sensor cable defect
sensor temperature too
high
Accumulator sensor short circuit, measuring circuit from acculmulator
sensor is shorted out
sensor defect
sensor cable defect
sensor temperature too
low
connect sensor at input
measure sensor (approx. 2kΩ
at 25°C) if required
replace sensor
sensor temperature above
measuring range (110°C)
measure sensor (approx. 2kΩ
at 25°C) replace if requiered
replace sensor
sensor temperature below
measuring range (– 10° C)