11 Malfunctions
Display:
Error code:
Description:
Cause and Remedy:
Display:
Error code:
Description:
Cause and Remedy:
Description:
Cause and Remedy:
14
Container cover open
Cover open
End-switch defect
15
DHW sensor fracture, measuring circuit from DHW sensor is open
sensor not connected
sensor defect
sensor cable defect
sensor temperature too high
DHW sensor short circuit, measuring circuit from boiler sensor is shor-
ted out
sensor defect
sensor cable defect
sensor temperature too low
close cover
replace end-switch
connect sensor at input
measure sensor (approx. 2kΩ
at 25°C) replace if required
replace sensor
sensor temperature above
measuring range (110°C)
measure sensor (approx. 2kΩ
at 25°C) replace if nrequired
replace sensor
sensor temperature below
measuring range (– 10° C)
Operating Manual