7.6 Wall Mounted Unit (IDU & ODU) Error Code Diagnosis and Solution
Running Lamp
Timer Lamp
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
1 time
OFF
2 times
OFF
3 times
OFF
4 times
OFF
5 times
OFF
5 times
OFF
5 times
OFF
5 times
OFF
5 times
OFF
6 times
OFF
6 times
OFF
12 times
OFF
9 times
OFF
8 times
OFF
7 times
FLASH
2 times
FLASH
3 times
FLASH
5 times
FLASH
1 time
FLASH
6 times
FLASH
7 times
FLASH
1 times
ON
Table 20
4 2 |
Display
Information
dF
Defrost
CL
Filter cleaning reminder(power on display for 15 seconds)
CL
Active clean
F
Filter replacement reminder(power on display for 15 seconds)
FP
Heating in room temperature under 8°C
FC
Forced cooling
AP
AP mode of WIFI connection
CP
Remote switched off
EH 00/EH 0A
Indoor unit EEPROM parameter error
EL 01
Indoor/outdoor unit communication error
EH 02
Zero-crossing signal detection error
EH 03
The indoor fan speed is operating outside of the normal range
EC 51
Outdoor unit EEPROM parameter error
EC 52
Condenser coil temperature sensor T3 is in open circuit or has short circuited
EC 53
Outdoor room temperature sensor T4 is in open circuit or has short circuited
EC 54
Compressor discharge temperature sensor TP is in open circuit or has short circuited
Evaporator coil outlet temperature sensor T2B is in open circuit or has short circuited
EC 56
(for free-match indoor units)
EH 60
Indoor room temperature sensor T1 is in open circuit or has short circuited
EH 61
Evaporator coil middle temperature sensor T2 is in open circuit or has short circuited
EC 07
The outdoor fan speed is operating outside of the normal range
EH b0
Indoor PCB/Display board communication error
EL 0C
Refrigerant leakage detection
PC 00
IPM malfunction or IGBT over-strong current protection
PC 01
Over voltage or over low voltage protection
Top temperature protection of compressor or High temperature protection of IPM
PC 02
module or High pressure protection
PC 04
Inverter compressor drive error
PC 08
Current overload protection
"Communication error between outdoor main chip and compressor
PC 40
driven chip"
PC 03
Low pressure protection
--
Indoor units mode confl ict(match with multi outdoor unit)
Bosch Wall Mounted Ductless Split Air Conditioner / Heat Pump IDU-ODU - BTC 769102301 A (11.2022)
Solution
Normal Display,
not error code
TS01-IDU
TS02-S-INV
TS03
TS04-S-IDU
TS01-ODU
TS05-ODU
TS05-ODU
TS05-ODU
TS05-ODU
TS05-IDU
TS05-IDU
TS04-ODU
TS07
TS06-INV
TS09-S
TS10-S
TS11-S-INV
TS12-S
TS08-S
TS33
TS13-INV
TS14