Bosch Climate 5000 Series Service Manual page 34

Wall mounted ductless split air conditioner/ heat pump
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

Service Manual
Number
Name
1
Power Supply
EEV-A
EEV-B
EEV-C
2
EEV-D
EEV-E
EEV-F
EEV-G
3
T3 T4 TP
4
H-PRO,L-RPO
5
OLP TEMP. SENSOR
6
TESTPORT
7
COMPRESSOR
8
DC-FAN
S-E
S-D
9
S-C(mono)
S-B
S-A
10
HEAT_D
11
HEAT_Y
12
4-WAY
13
/
Table 19
3 4 |
CN#
Description
CN11
N_in: connect to N-line (208-230V AC input)
L_in: connect to L-line (208-230V AC input)
CN16
CN13
CN3
CN15
connect to 12V electric expansion valve
CN1
CN17
CN14
CN26
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust temp. sensor TP
CN29
connect to high and low pressure swtich(pin1-pin2&pin3-pin4:5VDC pulse wave)
CN30
connect to compressor top temp. sensor (5VDC Pulse wave)
CN24
used for testing
U
connect to compressor
V
0V AC (standby)
W
10-200V AC (running)
CN32
connect to DC fan
CN31
CN5
S: connect to indoor unit communication(pin1-pin2: 24VDC Pulse wave; pin2-pin3: 208 230V AC
CN34
input)
CN2
CN4
CN8
connect to heater, 208-230V AC when is ON
CN20
CN21
connect to heater, 208-230V AC when is ON
CN36
CN38
connect to 4 way valve, 208-230V AC when is ON.
CN27
connect to key board CN1