Contens Exterior view of water heater PPE2. Pic1. Water heater PPE2. 2. Construction of water heater PPE2. Pic.2. Interior view. 2.1. Assembly of flow sensor and air sensor. Pic.2a. Air sensor and flow sensor. 2.2. Assembly of temperature sensors. Pic.2b. Temperature sensors 3.
2.1. Assembly of flow sensor and air sensor. Pic.2a. Flow sensor and air sensor. 00337 01284 01283 able p. Air sensor Check valve WC-3 probe 00255 Correct assembly of the flow sensor...
3. Parameters and construction of heating box. Pic.3. Heating box 01299 00627 01301 01298 le p 00627 01302 01300 Tab.1. Parameters of heating box Heating power [kW] Power of heating box 2500 4000 4500 Rated voltage Rated current 10,0 11,3 Heating element resistance [Ω] 64,00...
Switch no. 6- in „ON” position blocks access to the unit’s setting (this realtes to PPE2 and PPVE only). In this case, the LED display shows the desired temperature value (which has been adjusted before...
5. Electric connection of heating box. Pic.5. Electric connection of heating box. 01281 le p . 15 01345 400V AC Top view 01280 01396 Bottom view Service manual PPE2...
NA block appliance by the master BV - flow sensor device A1 - power board BLOK - block the slave unit A2 - MSP board XP - terminal strip A3 - control panel PPE2 BP - air sensor Service manual PPE2...
8. Control panel PPE2. Pic.8. Control panel PPE2. Display Control knob The heater switches on automatically straight after reaching the flow rate over 2,5 l/min. The temperature control system adjusts the power rate according to the water flow rate, required temperature and the temperature of water in the mains.
30 ÷ 60 Overall dimension (height x width x depth) 440 x 245 x 126 Weight Water fittings G 1/2” distance beetween inlet and outlet 100mm) 1100 The minimal resistivity of water at 15 °C Ωcm Opracował: Przemysław Biegański Service manual PPE2...