TxRx-mode generic flow control—Enabled by using the flow-control command. With
TxRx-mode generic flow control enabled, an interface can both send and receive flow control
frames:
When congestion occurs, the interface sends a flow control frame to its peer.
When the interface receives a flow control frame from its peer, it suspends sending packets
to its peer.
Rx-mode generic flow control—Enabled by using the flow-control receive enable
command. With Rx-mode generic flow control enabled, an interface can receive flow control
frames, but it cannot send flow control frames:
When congestion occurs, the interface cannot send flow control frames to its peer.
When the interface receives a flow control frame from its peer, it suspends sending packets
to its peer.
To handle unidirectional traffic congestion on a link, configure the flow-control receive enable
command at one end and the flow-control command at the other end. To enable both ends of a link
to handle traffic congestion, configure the flow-control command at both ends.
To enable generic flow control on an Ethernet interface:
Step
1.
Enter system view.
2.
Enter Ethernet interface
view.
3.
Enable generic flow
control.

Enabling EEE on an Ethernet interface

With Energy Efficient Ethernet (EEE) enabled, a link-up interface enters low power state if it has not
received any packet for a period of time. The time period depends on the chip specifications and is
not configurable. When a packet arrives later, the device automatically restores power supply to the
interface and the interface restores to the normal state.
This feature is supported only on copper ports on the following interface modules:
FD interface module: LSQM1GT48FD0.
SA interface module: LSQM2GT48SA0.
SC interface modules:
LSQM2GT24PTSSC0.
LSQM2GT24TSSC0.
LSQM4GV48SC0.
LSQM2GT48SC0.
For this feature to take effect on an interface, configure the interface to automatically negotiate
a speed or duplex mode with the remote end.
To enable EEE on an Ethernet interface:
Command
system-view
interface interface-type
interface-number
Enable TxRx-mode
generic flow control:
flow-control
Enable Rx-mode generic
flow control:
flow-control receive
enable
14
Remarks
N/A
N/A
By default, generic flow control is
disabled on an Ethernet interface.