5020803-UIM-M-0120
Table 9: Electric Heat Performance Data: 208/230-1-60
Nominal kW
1,2
Heater Models
6HK(0,1)6500206
6HK(0,1)6500506
6HK(0,1)6500806
6HK(0,1)6501006
1PH
6HK(1,2)6501306
6HK(1,2)6501506
6HK(1,2)6501806
6HK(1,2)6502006
6HK(1,2)6502506
1. (0,1) - 0 = no service disconnect OR 1 = with service disconnect.
2. (1,2) - 1 = with service disconnect, no breaker jumper bar OR 2 = with service disconnect and breaker jumper bar.
Table 10: Single Point Kit Numbers
Single Point Kit P/N
S1-2SPWK006
S1-2SPWK002
S1-2SPWK007
S1-2SPWK003
S1-2SPWK004
S1-2SPWK005
FIGURE 8: Single Point Wiring Kits
12
kW
@240 V
208 V
230 V
2.4
1.8
2.2
4.8
3.6
4.4
7.7
5.8
7.1
9.6
7.2
8.8
12.5
9.4
11.5
14.4
10.8
13.2
17.3
13
15.9
19.2
14.4
17.6
24.0
18
22
Unit Model Number
Total Heat
MBH
208 V
230 V
6.2
7.5
12.3
15
19.7
24.1
24.6
30.1
32
39.2
36.9
45.1
44.3
54.2
49.2
60.2
61.5
75.2
PHE4A24
PHE4A30
PHE4B36
PHE4B42
PHE4B48
PHE4B60
kW Staging
W1 Only
208 V
230 V
208 V
1.8
2.2
1.8
3.6
4.4
3.6
5.8
7.1
5.8
7.2
8.8
7.2
3.1
3.8
9.4
3.6
4.4
10.8
6.5
7.9
13
7.2
8.8
14.4
7.2
8.8
18
Breaker Size
25 A
Up to 13 kW
35 A
Up to 15 kW
40 A
Up to 15 kW
45 A
Up to 20 kW
50 A
Up to 20 kW
60 A
Up to 20 kW
Johnson Controls Ducted Systems
W1 + W2
230 V
2.2
4.4
7.1
8.8
11.5
13.2
15.9
17.6
22
Heat Kit