Handling
Technical measures/ precautions: Ensure the presence of sufficient ventilation and/or air extraction means in the
Recommendations for safe use:
Storage:
Control parameters:
Respiratory protection:
Protection of the eyes:
Protection of the hands:
Hygiene measures:
Colour:
Odour:
Boiling point:
Flash point:
Relative density:
Solubility in water:
Stability:
Materials to avoid:
Hazardous decomposition
products:
Acute toxicity:
Local effects:
Long-term toxicity:
Global warming potential GWP
(R11=1):
Ozone depletion potential ODP
(R11=1):
Considerations on disposal:
TAEevo Tech MINI 02÷10
HANDLING AND STORAGE
workplace.
Do not breath fumes or aerosol.
Close hermetically and store in a cool, dry and well-ventilated place. Store in its original
containers. Incompatible products: explosives, flammable materials, organic peroxide
CONTROL OF EXPOSURE/INDIVIDUAL PROTECTION
AEL (8-h and 12-h TWA) = 1000 ml/m3 for each of the two components.
For rescue and maintenance work in tanks use autonomous breathing apparatus. The
vapours are heavier than air and can cause suffocation, by reducing the oxygen available
for breathing.
Safety spectacles.
Rubber gloves.
Do not smoke.
PHYSICAL AND CHEMICAL PROPERTIES
Colourless.
Faint.
-52.8°C at atmospheric pressure.
Non-flammable.
1.08 kg/l at 25°C.
Negligible.
STABILITY AND REACTIVITY
No reactivity if used in compliance with instructions.
Highly oxidising materials. Incompatible with magnesium, zinc, sodium, potassium and
aluminium.
Incompatibility is more critical if the metal is present in the form of powder or if surfaces
have been recently unprotected.
These products are halogen compounds, hydrofluoric acid, carbon monoxides (CO,
CO2), carbonyl halides.
TOXICOLOGICAL INFORMATION
(R32) LC50/inhalation/4 hours/lab. rats 760 ml/l
(R125) LC50/inhalation/4 hours/lab. rats 3480 mg/l
Concentrations significantly above the TLV can cause narcotic effects.
Inhalation of products in decomposition can lead to respiratory difficulty (pulmonary
oedema).
No carcinogenic, teratogenic, or mutagenic effects observed in laboratory animals.
ECOLOGICAL INFORMATION
1730
0
Usable with reconditioning.
The data in this manual are not binding and they can be modified by the manufacturer without notice. Reproduction of this manual is strictly prohibited
OPERATING AND MAINTENANCE MANUAL
Chapter 2 - Safety
10