Page 2
The use of non-OEM replacement parts will void (or negate) agency certifications, including CE, ATEX, CSA, 3A and EC1935 compliance (Food Contact Materials). Warren Rupp, Inc. cannot ensure nor warrant non-OEM parts to meet the stringent requirements of the certifying agencies.
Page 3
Temperature Tables Table 1. Category 2 ATEX Rated Pumps Ambient Temperature Process Temperature Temperature Maximum Surface Range [°C] Range [°C] Class Temperature [°C] -20°C to +80°C T100°C -20°C to +108°C T135°C -20°C to +60°C -20°C to + 160°C T200°C -20°C to +177°C (225°C) T2 Table 2. Category M2 ATEX Rated Pumps for Mining Ambient Temperature Process Temperature Range [°C] Range [°C]...
Explanation of Pump Nomenclature Your Model #: F __ ____ ____ (fill in from pump nameplate) Pump Pump Check Design Wetted Diaphragm/ Check Valve Non-Wetted Porting Pump Muffler Pump Brand Size Valve Level Material Check Valve Seat Material Options Style Options Options Model #:...
Materials Material Profile: Operating Temperatures: Max. Min. CAUTION! Operating temperature limitations are as follows: EPDM: Shows very good water and chemical resistance . Has 280°F -40°F poor resistance to oils and solvents, but is fair in ketones and 138°C -40°C alcohols .
CAN BE REQUESTED IF PHYSICAL DIMENSIONS ARE NEEDED. NICKLE PLATED ELASTOMERIC MATERIA UPDATED TO CURRENT DESIGN 10/12/10 3309 ALL DIAPHRAGM REVISION DATE 13.97 [354.84] 1.50 [38.10] 10.28 [261.11] BOTTOM VIEW sandpiperpump • Model F15 Metallic f15mdl1sm-rev0219 PART NUMBER MADE FROM WARREN RUPP INC. E4SAxxxx0-FP SEE BOM...
Principle of Pump Operation Air-Operated Double Diaphragm (AODD) pumps are powered by compressed air or nitrogen . The main directional (air) control valve distributes ① compressed air to an air chamber, exerting uniform pressure over the inner surface of the diaphragm .
Recommended Installation Guide Available Accessories: 1. Surge Suppressor Unregulated Air Supply to Surge 2. Filter/Regulator Suppressor 1 Surge Suppressor 3. Air Dryer 4. Lubricator Pressure Gauge Note: Surge Suppressor and Shut-Off Valve Piping, including air line, must be supported after the flexible connections. Pipe Connection (Style Optional) Discharge...
Troubleshooting Guide Symptom: Potential Cause(s): Recommendation(s): Pump Cycles Once Deadhead (system pressure meets or exceeds air Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. supply pressure) . (Does not apply to high pressure 2:1 units) . Air valve or intermediate gaskets installed incorrectly .
Page 12
Composite Repair Parts Drawing FUSION FUSION TWO PIECE TWO PIECE DIAPHRAGM DIAPHRAGM DIAPHRAGM DIAPHRAGM Torque Setting: Torque Setting: 60 in-lbs. 60 in-lbs. (6 N-m) (6 N-m) Torque Setting: SEE PILOT Torque Setting: SEE PILOT 200 in-lbs. ASY DETAIL FUSION FUSION 200 in-lbs.
Page 13
Composite Repair Parts List Air Valve Assembly Item # Qty. Description Part Number Valve Body Assembly (includes items 2-8) P31-200-NP Valve Body P31-201NP End Cap P50-300NP End Cap Gasket P50-110 Valve Body Gasket P31-202 Valve Spool P50-104 Glyde Ring Assembly P50-104C Mounting Screws (8 included on item 1) S1001...
Page 14
Warren Rupp, Inc. (“Warren Rupp”) warrants to the original end-use purchaser that no product sold by Warren Rupp that bears a Warren Rupp brand shall fail under normal use and service due to a defect in material or workmanship within five years from the date of shipment from Warren Rupp’s factory.
Page 15
Declaration of Conformity Manufacturer: Warren Rupp, Inc., 800 N. Main Street, Mansfield, Ohio, 44902 USA certifies that SANDPIPER Air-Operated Double Diaphragm Food Processing Pump Models ® and Tranquilizer Surge Suppressor Models comply with the European Community Regulations: ® (EC) No 1935/2004 for Food Contact Materials...
Page 16
A Unit of IDEX Corporation 800 North Main Street Mansfield, OH 44902 USA Warren Rupp, Inc. declares that Air Operated Double Diaphragm Pumps (AODD) and Surge Suppressors listed below comply with the requirements of Directive 2014/34/EU and all applicable standards. Applicable Standards •...