Download Print this page

Technical Data; Warranty - CAMDEN CX-33 Installation Instructions Manual

Advanced logic relay
Hide thumbs Also See for CX-33:

Advertisement

Section 4 _________________
System Inspection Instructions
After the Installation and operational check of the
system:
1. Place any applicable labels on the door (as
per ANSI A156.10 or A156.19 guidelines).
2. Instruct the owner on door system operation
and how to walk-test it.
checked on a daily basis.
3. Instruct the owner on what to do if the door or
any of its components become damaged.
4. Strongly recommend to the owner that the
complete entry be inspected twice a year as
part of the service agreement, or at least
once per year as per AAADM guidelines.
Section 6_________________

Warranty

Camden Door Controls guarantees the CX-33 to be free from manufacturing defects for 3 years from date of sale. If
during the first 3 years the CX-33 fails to perform correctly, it may be returned to our factory where it will be repaired
or replaced (at our discretion) without charge. Except as stated herein, Camden extends no warranties expressed or
implied regarding function, performance or service.
This should be
Call us toll-free at 1-877-226-3369
5502 Timberlea Blvd.,
Mississauga, ON Canada L4W 2T7
CX-33 Advanced Logic Relay Installation Instructions
Section 5_________________

Technical Data

Model
Dimensions
Enclosure
Mounting
Operating Temp
Display
Programming
Operating voltage
Current Draw
Inputs
Response time
Relay Output
Relay contact rating 3 amps @ 24 VDC
Time Delays
Questions?
www.camdencontrols.com
Toll Free: 1.877.226.3369
CX-33
6" x 2" x 7/8" (152 x 51 x 22mm)
Clear plastic case
(2) #8 screws or Velcro
-22F to +185F (-30C to +85C)
Blue multi-segment LED
MENU, UP & DOWN buttons
12/24 Volts, AC/DC
105 mA standby, 320 mA max.
4 x "dry" contacts; and
1 x "wet" contact (4.5-120 V
AC/DC, Optically isolated,
non-polarity sensitive)
0.5 seconds
3 x Form C (SPDT)
Hold 1 timer: 0 - 50 seconds
Delay 1 timer: 0 – 15 seconds
Hold 2 timer: 0 – 50 seconds
Delay 2 timer: 0 – 60 seconds
Hold 3 timer: 0 – 50 seconds
Page 7 of 22