Section 3_________________
Set-up Instructions
APPLICATIONS:
3-Relay Switching Network
(Mode 1) Proceed to section 3A
2-Door Airlock (Timed)
(Mode 2) Proceed to section 3B
2 Door Airlock (Latching)
(Mode 3) Proceed to section 3C on Page 3
Bi-Directional Door sequencer (w/lock)
(Mode 4) Proceed to section 3D on Page 3
Apartment / Condo Applications
(Mode 5) Proceed to section 3E
Access Control Applications
(Mode 6) Proceed to section 3F
Restroom Control (normally unlocked)
(Mode 7) Proceed to section 3G on Page 4
Restroom Control (normally locked)
(Mode 8) Proceed to section 3H
Lock-out Relay w/switching network
(Mode 9) Proceed to section 3J
Low Energy S.A.M. w/switching network
(Mode 10) Proceed to section 3K on Page 5
Mag lock with N.O. Fire Alarm input
(Mode 11) Proceed to section 3L on Page 6
Mag lock with N.C. Fire Alarm input
(Mode 12) Proceed to section 3M on Page 6
Special purpose sequencer
(Mode 13) Proceed to section 3N on Page 6
System Inspection Instructions
Technical Specifications, & Warranty
Section 3A_________________
3 Relay Switching network (Mode 1)
This mode sequences all 3 relays (in one direction),
using what we call "mixed mode triggering". Some
popular applications include basic strike and operator
installations, smoke evacuation, stairwell doors, or
latching applications.
Refer to Diagram 1, (Page 9) for the following
connections.
For momentary devices, wire to either DRY 1 or WET
1 input terminals. Wire a maintained device to DRY 3
input if you wish to hold relay 1 (a lock for example).
Wire a maintained device to DRY 2 input if you wish
to hold relays 2 & 3 (ie -door operators).
Input number 4 is for latching applications. Each
momentary switch closure will toggle relays 2 & 3.
5502 Timberlea Blvd.,
Mississauga, ON Canada L4W 2T7
CX-33 Advanced Logic Relay Installation Instructions
Once input and output connections are made,
program
Programming Instructions on page 1, and walk-test
the installation. Timing adjustments may need to be
made.
If Hold time is = 0, the relay doesn't turn on. If Delay
on Page 2
time = 0, then the relay comes on immediately. For
example, if you wish Relay 2 & 3 to both come on at
on Page 2
the same time, set D2 time to zero (0.0).
In addition, you can add a "Delay-on-activate" (or
nuisance delay) to this mode by setting time via Step
8 of the Program Mode. If this feature is used, any
input will have to be held for at least the time
indicated on the display before the CX-33 will
on Page 3
activate. If this feature is not wanted, set the time to
zero (0.0)
on Page 4
Once the desired operation is achieved, proceed to
Section 4, Pg 7 for System Inspection Instructions.
Section 3B_____________
on Page 4
2 Door Timed Airlock (Mode 2)
on Page 5
Utilizing door position switches (Camden CX-MDC or
equivalent), this mode ensures that only one door in
an airlock will be open at a time. Each output hold
time is adjustable from 1 – 50 seconds. 3 outputs
allow for one of the doors to have an electric lock and
a door operator. (Alternatively, the doors could have
locks only and no operators.)
Refer to Diagram 2, (Page 10) for the following
Page 7
connections.
Page 7
Wire the activating device(s) for Door #1 to DRY 1
terminals. Wire the activating device(s) for Door #2
to DRY 2 terminals. Wire the respective door contact
switches to Inputs 3 & 4. (The contact circuit must be
closed when the door is closed).
Wire the outputs as shown.. If a lock is not used, set
H1 & D1 timers to zero (0.0), and Relay 1 will be
ignored.
Once input and output connections are made,
program
Programming Instructions on page 1, and walk-test
the installation. Timing adjustments may need to be
made.
It is NOT recommended to add the "Delay-on-
activate" (or nuisance delay) feature in this mode!
Once the desired operation is achieved, proceed to
Section 4, Pg 7 for System Inspection Instructions.