NOTES:
1. Solid lines are the Secondary Activation Mode
(SAM) circuit. Dashed lines are switching network
circuit and are optional.
2. SAM Circuit complies with ANSI A156.19 when
wired as shown.
3. Sensor is only active after Switch is pressed,
and remains active until door closes.
4. The CX-33 also resets after 60 seconds if the
door never opens. (safety feature)
5. Operator Control box terminals: A = Active,
C = Common, S = Safety.
12 - 24 V
AC/DC
Power
Door
Operator
Door Mounted Sensor
Activating
Switch(es)
Magnetic
Contact
Switch
N.C.
DISPLAY
0.10
CX-33
MENU
UP
DOWN
Activating
Switch(es)
SCALE: NONE
DRAWN BY: DGW
(Mode 10) Low Energy S.A.M. plus Switching Network Wiring Diagram
DRAWING No: DRG-CX-33-10
LED 1
LED 2
LED 3
Relay 1
Relay 2
Relay 3
A
C
S
Power
for Strike
MOV
Camden Door Controls
DATE: 08/15/13
FILENAME:
Operator
Control
Box
Fail-Secure
Electric Strike
Shown
(If Fail-Safe lock
is used, wire to
Terminals 1 & 2)
5502 Timberlea Blvd
Mississauga, Ontario
L4W 2T7
REVISED: