Once input and output connections are made,
program
the
unit
according
Programming Instructions on page 1, and walk-test
the installation. Timing adjustments may need to be
made.
In addition, you can add a "Delay-on-activate" (or
nuisance delay) to this mode by setting time via Step
8 of the Program Mode. If this feature is used, any
input will have to be held for at least the time
indicated on the display before the CX-33 will
activate. If this feature is not wanted, set the time to
zero (0.0)
Once the desired operation is achieved, proceed to
Section 4, Pg 7 for System Inspection Instructions.
Section 3F____________________
Access Control Application (Mode 6)
This application is for a control relay that takes a
maintained signal and unlocks a door for an extended
time. During this time, an exterior momentary switch
is put into the circuit to allow the door to activated
automatically. After the access system or time-clock
has released the signal, the door relocks, and the
exterior switch is removed from the circuit. At any
time, the inside switch will unlock and open the door.
Refer to Diagram 6, (Page 15) for the following
connections.
The CX-33 allows for dry and/or powered maintained
connections to the Access System / time clock (DRY
1 and/or WET inputs respectively). Wire the Exterior
momentary Switch" to DRY 2 input. Wire the inside
momentary switch to DRY 3 input. An optional Key
switch can be added for use by tenants - wire to
either DRY 1 (to unlock only), or DRY 3 (to unlock
and open door).
Output #1 is for the electric lock, and Output #2 is for
the door operator. (Optional - Output #3 is controlled
solely by DRY 4 Input).
Once input and output connections are made,
program
the
unit
according
Programming Instructions on page 1, and walk-test
the installation. Timing adjustments may need to be
made.
In addition, you can add a "Delay-on-activate" (or
nuisance delay) to this mode by setting time via Step
8 of the Program Mode. If this feature is used, any
input will have to be held for at least the time
indicated on the display before the CX-33 will
activate. If this feature is not wanted, set the time to
zero (0.0)
5502 Timberlea Blvd.,
Mississauga, ON Canada L4W 2T7
CX-33 Advanced Logic Relay Installation Instructions
to
the
General
to
the
General
Once the desired operation is achieved, proceed to
Section 4, Pg 7 for System Inspection Instructions.
Section 3G____________________
Normally Unlocked Restroom (Mode 7)
In this mode, control of a single occupant barrier-free
washroom is obtained. It allows the user to lock and
secure the door from the inside by depressing a
Push-to-Lock button (once door is in the closed
position).
The exterior wall switch is removed
electronically from the circuit.
To exit the washroom, simply exit manually via the
store-room function lever-handle set (the Door
Contact Switch resets the relay), or, press the interior
wall switch to unlock and signal the door operator.
The door remains unlocked upon closure (see Mode
8 for normally locked doors).
provides a relay dedicated for "Occupied" & "Door
Locked" signage.
Refer to Diagram 7, (Page 16) for the following
connections.
The outside wall switch, inside wall switch, and Push-
to-Lock switch are all N.O. momentary switches.
Connect as shown. The Door Contact Switch circuit
must be closed when the door is closed and open
when the door opens.
A fail-safe electric strike is recommended and
connects to Relay 1 (although a fail-secure strike can
also be used). The automatic door operator connects
to Relay 2, and the signage connects to Relay 3. (As
a reminder, no power is provided on the relay outputs
– they are dry contacts).
Once input and output connections are made,
program
the
unit
according
Programming Instructions on page 1, and walk-test
the installation. Timing adjustments may need to be
made.
It is NOT recommended to add the "Delay-on-
activate" (or nuisance delay) feature in this mode!
Once the desired operation is achieved, proceed to
Section 4, Pg 7 for System Inspection Instructions.
Section 3H____________________
Normally Locked Restroom (Mode 8)
In this mode, control of a normally locked single
occupant barrier-free washroom is obtained. It allows
the user to secure the door from the inside by
depressing a Push-to-Lock button.
means of ingress is removed electronically from the
circuit.
www.camdencontrols.com