CAMDEN CX-33 Installation Instructions Manual page 21

Advanced logic relay
Hide thumbs Also See for CX-33:

Advertisement

12 - 24 V
AC/DC
Power
Wire Momentary
Switch(es)
to Input 1
Maintained
Signal on
Input 2 holds
Outputs 2 & 3
(optional)
Fire Alarm Input.
N/C dry contact
unlocks door
and disables
normal operation
CX-33
MENU
Powered
Signal
ie - RF
Receiver
(same as
Dry 1)
SCALE: NONE
FIRE
LED 1
DISPLAY
0.12
LED 2
LED 3
Relay 1
Relay 2
Relay 3
UP
DOWN
Power
for Mag
Magnetic
Contact
N.C.
Switch
Camden Door Controls
DRAWN BY: DGW
(Mode 12) Deactivation Timer for Mag Lock Wiring Diagram
DRAWING No: DRG-CX-33-12
NOTES:
1. The magnetic contact Switch circuit must be
closed when the door is closed, and open when
the door opens.
2. When the N/C Fire Alarm Circuit opens, the
Mag Lock is released, and the wall switch inputs
are disabled.
3. All items in dashed lines are optional.
Door
Operator
Mag Lock
5502 Timberlea Blvd
Mississauga, Ontario
L4W 2T7
DATE: 07/05/13
REVISED:
FILENAME:
CX-33 Diagram 12.vsd