CAMDEN CX-33PS Installation Instructions Manual

Advanced logic control relay & power supply cabinet

Advertisement

Quick Links

E l ec t r if i e d Lo ck s , Re l a y s a nd Ti mers
CX-33PS
Advanced Logic Control Relay & Power Supply Cabinet
INSTALLATION INSTRUCTIONS
THIS PACKAGE INCLUDES:
(1) Metal Cabinet
(1) Pre-wired CX-33 Relay
(1) Hardware Kit
(1) 2 Amp Power Supply
1. DESCRIPTION
The CX-33PS is designed to make installations easier and quicker
by having Camden's advanced relay logic controller (CX-33) pre-
wired to a color-coded set of labeled terminal strips. CX-33's 15
operating modes will handle a wide variety of applications from
Vestibule openings to Card Access and Alarm Integration.
Its attractive metal cabinet also provides a pre-mounted 2 amp
12/24 VDC filtered and regulated power supply with enough
current to run options such as Camden's Aura illumination
boards, Emergency Call kits, and lock power. Camden CX-33PS
provides a clean and organized location for field wiring.
Backed by Camden's 3-year warranty.
2. SPECIFICATIONS
AC Input: 12V to 28V
Voltage
2 Amps
Current Supply
Battery Backup
Gel Type Battery (not supplied)
AC and DC Output
LED Indicator
Operating: 0° C to 49° C (32° F to 120° F )
Temperature
Storage : - 20° C to 70° C ( - 4° F to 158° F )
(4) Dry, (1) Wet 5V to 120V AC/DC,
Inputs
Non-Polarity Optically Isolated
(3) Form 'C' (SPDT), 3 Amps @ 24V DC
Outputs
Hold 1 Timer: 0 to 50 seconds Delay 1
Timer: 0 to 15 seconds
Hold 2 Timer: 0 to 50 seconds Delay 2
Time Delay
Timer: 0 to 60 seconds
Hold 3 Timer: 0 to 50 seconds
Delay on Activate: 0 to 10 seconds
7-7/8" W x 11-1/16" H x 2-13/16" D
Dimensions
(200mm x 281mm x 72mm)
(1) CX-TRX-5024 50VA
Class 2 transformer
3. DIMENSIONS
4. INSTALLATION
DC Output: 12 or 24V
IMPORTANT: Do not apply power to the unit until you have read
the instructions fully and made the required adjustments.
Mounting
The CX-33PS cabinet should be mounted in a clean dry location
out of direct contact with the elements.
Using a level, position the CX-33PS cabinet at the desired
location and mark the four holes needed to mount it to the
wall. Using the supplied wall anchors (concrete or drywall)
and screws, fasten the CX-33PS to the wall.
Wiring
IMPORTANT: Confirm the electrical panels breaker you are
going to be using is currently off. Do not wire the primary
terminals of the transformer until the secondary terminals
are connected first.
Wiring the CX-33PS will be based on which one of the 15 available
modes is selected to best suit your application (the modes
are discussed in detail in the CX-33 installation manual). Once
the mode is chosen, wiring the field devices is simplified by
connecting each item to its own labeled input. There are
dedicated inputs for PUSH TO OPEN/PUSH TO LOCK push
plates (interior/exterior), door contacts (provides door status to
the CX-33PS), dry and wet trigger inputs (for Access Control/
Alarm/Fire integration), and a VAC input from the supplied
step-down transformer.
2-13/16" (72mm)
7-7/8" (200mm)
11-1/16" (281mm)
Page 1 of 26

Advertisement

Table of Contents
loading

Summary of Contents for CAMDEN CX-33PS

  • Page 1 Hold 1 Timer: 0 to 50 seconds Delay 1 are connected first. Timer: 0 to 15 seconds Wiring the CX-33PS will be based on which one of the 15 available Hold 2 Timer: 0 to 50 seconds Delay 2 Time Delay...
  • Page 2: Mode

    Confirming wired connections is simplified by being able to remove any field input device and testing the CX-33PS directly on its dedicated labeled terminal position. IMPORTANT: Do not apply power to the unit until you have fully read the instructions and have confirmed your connections.
  • Page 3: Table Of Contents

    CX-33PS Advanced Logic Control Relay & Power Supply Cabinet INSTA LL AT ION INS T RUCT IONS Programmable Inputs Section 3 A 3 Relay Switching network (Mode 1) The Dry and Wet Inputs are programmable to accept either a Normally Open or Normally Closed contact. Table 1 shows the This mode sequences all 3 relays (in one direction), using what default settings for all modes.
  • Page 4: Mode

    CX-33PS Advanced Logic Control Relay & Power Supply Cabinet INSTA L L AT I O N I NST RU CTI ONS In addition, you can add a “Delay-on-activate” (or nuisance Section 3 C delay) to this mode by setting time via Step 8 of the Program 2 Door Latching Airlock (Mode 3) Mode.
  • Page 5: Section 3G

    CX-33PS Advanced Logic Control Relay & Power Supply Cabinet INSTA LL AT ION INS T RUCT IONS Wire the inside momentary switch to DRY 3 input. An optional Section 3 H Key switch can be added for use by tenants - wire to either DRY Normally Locked Restroom (Mode 8) 1 (to unlock only), or DRY 3 (to unlock and open door).
  • Page 6: Switching Network

    CX-33PS Advanced Logic Control Relay & Power Supply Cabinet INSTA L L AT I O N I NST RU CTI ONS LOR Circuit: Relay 3 output is to be connected to the Activate circuit of the door operator. A parallel connection is made to the two motor wires running from the Operator (motor) to its control.
  • Page 7: Access Control Input

    CX-33PS Advanced Logic Control Relay & Power Supply Cabinet INSTA LL AT ION INS T RUCT IONS Section 3 N Input 2 allows for an optional secure entry keypad (or similar), or connection to a fire alarm. Special Purpose Sequencer (Mode 13) Once connections are made, power up and program the unit In this mode, Input 1 sequences Relays 1 &...
  • Page 8: System Inspection Instructions

    CX-33PS Advanced Logic Control Relay & Power Supply Cabinet INSTAL L AT ION INS T RUCT IONS Section 4 Section 5 Warranty System Inspection Instructions Camden Door Controls guarantees the CX-33 to be free from After the Installation and operational check of the system: manufacturing defects for 3 years from date of sale.

Table of Contents