Richter BVA/F Series Installation And Operating Manual

Richter BVA/F Series Installation And Operating Manual

Standard ball valve to asme with ball/stem unit or ball and stem, cone shape stem sealing
Table of Contents

Advertisement

Quick Links

INSTALLATION AND OPERATING MANUAL
Series
BVA/F, BVAP/F
Standard Ball Valve to
ASME
with ball/stem unit or ball and stem, cone shape
stem sealing
Keep for future use!
This operating manual must be strictly observed before
transport, installation, operation and maintenance
Subject to change without notice.
Reproduction is generally permitted with indication of the source.
© Richter Chemie-Technik GmbH.
9520-036-en Revision 19 Edition 05/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BVA/F Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Richter BVA/F Series

  • Page 1 Keep for future use! This operating manual must be strictly observed before transport, installation, operation and maintenance Subject to change without notice. Reproduction is generally permitted with indication of the source. © Richter Chemie-Technik GmbH. 9520-036-en Revision 19 Edition 05/2022...
  • Page 2: Table Of Contents

    Series BVA/F, BVAP/F to ASME Page 2 List of Contents 9 Maintenance ........11 List of Contents ......... 2 9.1 Dismantling ..........11 Relevant documents ......... 3 9.1.1 BVA/F with lever ........... 11 1 Technical data ........3 9.1.2 Ball valve with actuator ......... 11 9.2 Assembly BVA/F, BVAP/F with ball/stem 1.1 Type plate, CE and body markings .....
  • Page 3: Relevant Documents

    These tests are not object of the tests at See sectional drawing in Section 10 Richter and have to be arranged by order Wear parts : Seat rings with Richter (e.g. point 3.3: High Pressure stem seal Closure Test).
  • Page 4: Type Plate, Ce And Body Markings

    Series BVA/F, BVAP/F to ASME Page 4 Options : Tightening torques ♦ Lever elevation depending on requirements All screws greased, tighten in diametrically ♦ Limit switches for remote monitoring of hand and opposite sequence! remote-activated ball valves The tightening torques for pipe screws and body ♦...
  • Page 5: Actuating Torques

    Series BVA/F, BVAP/F to ASME Page 5 Actuating torques According to ASME B 16.42 PFA lined ball/stem unit Test medium: water 68 °F (20 °C) Higher actuating torques may occur with other media. PFA lined ball/stem unit Δp in psi max.
  • Page 6: Notes On Safety

    Intended use Ball valves are on/off valves. Richter ball valves of the series BVA/F and BVAP/F are pressure containing components in accordance with the Pressure Equipment Directive (PED) for the passage and shut-off of fluids. The valves are suitable...
  • Page 7: Safety Notes For Applications In Potentially Explosive Areas Based On The Directive 2014/34/ Ec (Atex)

    Series BVA/F, BVAP/F to ASME Page 7 Safety notes for applications in potentially explosive areas based on the Directive 2014/34/ EC (ATEX) The valves are intended for use in a potentially This means that, to safely prevent ignitions, the explosive area and are therefore subject to the valve must be completely filled with medium at all conformity assessment procedure of the directive times or else a potentially explosive atmosphere...
  • Page 8: Safety Note For Valves, Certified To Clean Air Act (Ta-Luft)

    Series BVA/F, BVAP/F to ASME Page 8 ♦ The valve must be grounded. and, if required, be designed in compliance with ATEX. This can be achieved in the simplest way via the ♦ Special attention must be paid to the appropriate pipe screws using tooth lock washers.
  • Page 9: Installation

    PTFE-lined gaskets with a metal inlay should be used. These gaskets are available as special accessories in the Richter range. Grounding Fig. 2 ball/stem unit in closed position The valve must be grounded.
  • Page 10: Operation

    Series BVA/F, BVAP/F to ASME Page 10 Operation ♦ Increased wear occurs in operation with solids Initial commissioning contents. ♦ Operation during cavitation leads to increased Normally, the valves have been tested for leaks with air or water. Prior to initial operation check cover wear.
  • Page 11: Maintenance

    Series BVA/F, BVAP/F to ASME Page 11 Maintenance ♦ All repair work is to be performed by qualified Assembly BVA/F, BVAP/F personnel using the appropriate tools. with ball/stem unit ♦ For the arrangement, designation and item numbers of all parts of the valve, see Section 9. ♦...
  • Page 12: Dismantling Bva/F, Bvap/F With Ball And Stem

    Series BVA/F, BVAP/F to ASME Page 12 Dismantling BVA/F, BVAP/F Assembly BVA/F, BVAP/F with ball and stem with ball and stem ♦ Prior to assembly all parts are to be cleaned and It is possible with a BVA/F, BVAP/F with ball and stem to replace the seat rings and ball without the plastic-lined parts checked for damage.
  • Page 13: Bvap/F With Actuator

    Series BVA/F, BVAP/F to ASME Page 13 9.4.3 BVAP/F with actuator Conversion from lever to actuator ♦ Mount spring gland follower 502 (at 4" and 6" are 2 spring gland followers 502) and packing gland ♦ Select the actuator in accordance with the follower 503.
  • Page 14: Drawings

    Series BVA/F, BVAP/F to ASME Page 14 Drawings 10.1 Legend main body 554/1 washer body end piece grounding spring washer ball lever stop ball/stem unit coupling includes: stem ring (option) lever pressure spring seat ring 980/1 round head grooved pin stem seal actuator includes:...
  • Page 15: Sectional Drawing Bva/F 1" To 2" With Lever

    Series BVA/F, BVAP/F to ASME Page 15 10.3 Sectional drawing BVA/F 1“ to 2“ with lever Drawing indicates ball valve with ball/stem unit Holes of the flange- and housing screws view displaced by 45°. 9520-036-en Revision 19 TM 10477 Edition 05/2022...
  • Page 16: Sectional Drawing Bva/F 3" To 6" With Lever

    Series BVA/F, BVAP/F to ASME Page 16 10.4 Sectional drawing BVA/F 3“ to 6“ with lever Drawing indicates ball valve with ball/stem unit and reduced bore Holes of the flange- and housing screws view displaced by 45°. 9520-036-en Revision 19 TM 10477 Edition 05/2022...
  • Page 17: View And Section Ball Valve With Lever

    Series BVA/F, BVAP/F to ASME Page 17 10.5 View and section Ball valve with lever 10.6 Section ball valve with actuator 9520-036-en Revision 19 TM 10477 Edition 05/2022...
  • Page 18: Sectional Drawing Bvap/F 1" To 2" With Actuator

    Series BVA/F, BVAP/F to ASME Page 18 10.7 Sectional drawing BVAP/F 1“ to 2“ with actuator Drawing indicates ball valve with ball/stem unit Holes of the flange- and housing screws view displaced by 45°. 9520-036-en Revision 19 TM 10477 Edition 05/2022...
  • Page 19: Sectional Drawing Bvap/F 3" To 6" With Actuator

    Series BVA/F, BVAP/F to ASME Page 19 10.8 Sectional drawing BVAP/F 3“ to 6“ with actuator Drawing indicates ball valve with ball/stem unit and reduced bore Holes of the flange- and housing screws view displaced by 45°. 9520-036-en Revision 19 TM 10477 Edition 05/2022...
  • Page 20: Dimensional Drawing Bva/F With Lever

    Series BVA/F, BVAP/F to ASME Page 20 10.9 Dimensional drawing BVA/F with lever 1" 1½" red. 2" 3" red. 4" red. 6" red. 0.96 1.87 3.07 3.78 inch [mm] [24.5] [47.5] [78] [96] 7.99 9.01 10.51 inch [165] [mm] [127] [178] [203] [229]...
  • Page 21: Dimensional Drawing Bvap/F With Actuator

    Series BVA/F, BVAP/F to ASME Page 21 10.10 Dimensional drawing BVAP/F with actuator 9520-036-en Revision 19 TM 10477 Edition 05/2022...
  • Page 22 Series BVA/F, BVAP/F to ASME Page 22 10.10.1 Table to dimensional drawing BVAP/F 1" 1½" red. 2" 3" red. 4" red. 6" red. 0.96 1.87 3.07 3.78 inch [mm] [24.5] [47.5]] [78] [96] 7.99 9.01 10.51 inch [165] [mm] [127] [178] [203] [229]...
  • Page 27 Waste Management Law (AbfG) and the Water Resources Act (WHG) An inspection/repair of Richter products and parts will only take place, if the attached explanation is filled out cor- rectly and completely by authorized and qualified technical personnel and is available.
  • Page 28 Safety Information / Declaration of No Objection Concerning the Contamination of Richter-Pumps, -Valves and Components SCOPE AND PURPOSE Each entrepreneur (operator) carries the responsibility for the health and safety of his employees. This extends also to the personnel, who implements repairs with the operator or with the contractor.
  • Page 29  for credit note Phone : Fax : End user : A. Details of Richter-product: Failure description: Classification: Article number: Serial number: B. Condition of the Richter- product: Contamination : Was it in operation ?   toxic  ...
  • Page 30 Email: RichterCedarFalls-Info@idexcorp.com Email: RichterMumbai-Info@idexcorp.com Internet: www.richter-inc.com Internet: www.richter-ct.com © Richter Chemie-Technik GmbH 2022 Edition 09/2022 Revision 2.0 Subject to change without notice. 9520B036-en These installation and operating instructions must be kept! Richter™ = Richter Chemie-Technik GmbH; IDEX™ = IDEX Corporation...

This manual is also suitable for:

Bvap/f series

Table of Contents