Round boiling pans

Advertisement

• See the installation diagram for the type and position of
appliance connections.
E E . . 6 6
G G a a s s C C o o n n n n e e c c t t i i o o n n s s
E E . . 6 6 . . 1 1
I I n n t t r r o o d d u u c c t t i i o o n n
C C A A U U T T I I O O N N
This appliance is arranged and tested to
operate with G20 gas 20 mbar;
To convert it to another type of gas, follow the instructions in
E.6.6 Conversion to another type of gas paragraph of this
section.
E E . . 6 6 . . 2 2
F F u u m m e e e e x x h h a a u u s s t t
• "A1" type appliances have to be positioned under an
extraction hood to ensure removal of fumes and steam
produced by cooking;
(not relevant for Australian standard).
For A A U U S S T T R R A A L L I I A A : the ventilation must be in accordance with
Australian building codes and kitchen exhaust hoods must
comply with AS/NZS1668.1 and AS 1668.2.
E E . . 6 6 . . 3 3
B B e e f f o o r r e e c c o o n n n n e e c c t t i i n n g g
1. Make sure the appliance is arranged for the type of gas to
be used.
Otherwise, carefully follow the instructions given in E.6.6
Conversion to another type of gas paragraph of this
section.
2. Fit a rapid gas shutoff tap/valve ahead of each appliance.
3. Install the tap/valve in an easily accessed place.
4. Clean the pipes to remove any dust, dirt or foreign matter
which could block the supply.
The gas supply line must ensure the gas flow necessary
for full operation of all the appliances connected to the
system.
A supply line with insufficient flow will affect correct
operation of the appliances connected to it.
I I M M P P O O R R T T A A N N T T
Incorrect levelling of the appliance can affect
combustion and cause malfunctioning.
E E . . 6 6 . . 4 4
C C o o n n n n e e c c t t i i o o n n ( ( d d e e p p e e n n d d i i n n g g o o n n t t h h e e a a p p p p l l i i a a n n c c e e a a n n d d / / o o r r
m m o o d d e e l l ) )
Monoblock models
1. See the installation diagram for the position of the gas
connection on the bottom of the appliance.
2. Remove the plastic cap protection (if present) from the
gas manifold before connecting.
Countertop models (Only for N9E range)
1. See the installation diagram for the position of the gas
connection on the bottom of the appliance.
2. Remove the plastic cap protection (if present) from the
gas manifold before connecting.
3. Countertop models can be connected to the gas supply
also using the rear connection:
a. operate at the back appliance;
b. unscrew the metal closing plug of the rear connection;
16
c. screw it tightly onto the bottom connection.
1
After installation, use soapy water to check connections for
leaks.
NOTE!
O O n n l l y y f f o o r r A A u u s s t t r r a a l l i i a a : The gas connection is male 1/
2 BSP.
E E . . 6 6 . . 5 5
G G a a s s p p r r e e s s s s u u r r e e r r e e g g u u l l a a t t o o r r
The section of the gas supply line must be sufficient to ensure
the gas flow necessary for full operation of all the appliances
connected to the system.
If the gas pressure is higher than that specified or is difficult to
regulate (not stable), install a gas pressure regulator (acces-
sory code 927225) in an easily accessed position ahead of the
appliance.
The pressure regulator should preferably be fitted horizontally,
to ensure the right outlet pressure.
1
connection side gas from mains
2
pressure regulator
3
connection side gas towards the appliance
The arrow on the regulator
flow direction.
2 2
F F o o r r A A u u s s t t r r a a l l i i a a : Adjust the test point pressure with burners
operating at maximum setting (see table "B" of Appendix)
E E . . 6 6 . . 6 6
C C o o n n v v e e r r s s i i o o n n t t o o a a n n o o t t h h e e r r t t y y p p e e o o f f g g a a s s
Nozzle Table "B" (see Appendix) gives the type of nozzles to
be used when replacing those installed by the manufacturer
(the number is engraved on the nozzle body).
At the end of the procedure, carry out the following check-list:
1. burner nozzle/s replacement
2. correct adjustment of primary air supply to burner/s
3. pilot nozzle/s replacement
4. minimum flame screw/s replacement
5. correct adjustment pilot/s if necessary
6. correct adjustment of supply pressure (see technical data/
gas nozzles table)
7. apply sticker (supplied) with data of new gas type used
2
indicates the gas
3 3
1 1

Advertisement