8. Prior to operation, test the gas pressure regulator for leaks.
B
D
E E . . 1 1 0 0
E E l l e e c c t t r r i i c c a a l l c c o o n n n n e e c c t t i i o o n n s s
E E . . 1 1 0 0 . . 1 1 E E l l e e c c t t r r i i c c a a p p p p l l i i a a n n c c e e s s
W W A A R R N N I I N N G G
Before connecting, make sure
the mains voltage and frequency
match those indicated on the
appliance data plate.
To access the terminal board "Me",
1. Undo the fixing screws.
2. Remove the appliance front panel.
3. Connect the power cable to the terminal block according
to the wiring diagram provided with the appliance.
4. Secure the power cable with the cable clamp "E".
Me
Me
I I M M P P O O R R T T A A N N T T
The manufacturer declines any liability if the safety
regulations are not respected.
E E . . 1 1 0 0 . . 2 2 G G a a s s a a p p p p l l i i a a n n c c e e s s
NOTE!
Before connecting, make sure the mains voltage
and frequency match those indicated on the
appliance dataplate.
To access the terminal board "Mg"
1. Undo the fixing screws;
18
A
C
E E
2. Remove the appliance front panel;
3. Connect the power cable to the terminal block according
to the wiring diagram provided with the appliance;
4. Secure the power cable with the cable clamp "E".
Mg
Mg
I I M M P P O O R R T T A A N N T T
The manufacturer declines any liability if the safety
regulations are not respected.
E E . . 1 1 0 0 . . 3 3 P P o o w w e e r r c c a a b b l l e e
Unless otherwise specified, our appliances are not equipped
with a power cable.
The installer must use a flexible cable having characteristics
not lower than the H05RN-F rubber insulated type.
Protect the section of cable outside the appliance with a metal
or rigid plastic tube.
E E . . 1 1 0 0 . . 4 4 C C i i r r c c u u i i t t b b r r e e a a k k e e r r
Verify that a safety circuit breaker is installed between the
power cable of the appliance and the mains electric line.
The contact opening max. distance and leakage current must
comply with the local safety regulations.
E E . . 1 1 0 0 . . 5 5 E E q q u u i i p p o o t t e e n n t t i i a a l l n n o o d d e e a a n n d d E E a a r r t t h h c c o o n n n n e e c c t t i i o o n n
Connect the appliance to an earth; it must be included in an
equipotential node by means of the screw located at the front
right under the frame.
The screw is marked with the symbol
E E . . 1 1 1 1
W W a a t t e e r r c c o o n n n n e e c c t t i i o o n n s s
The appliance must be fed with drinking water at a pressure
of 1.5 – 3 bar.
C C A A U U T T I I O O N N
If the water pressure is higher than that
specified, use a pressure reducer to avoid
damaging the appliance;
For correct installation, water inlet pipe "P" (see picture below)
must be connected to the mains using a mechanical filter and a
shutoff valve.
Before connecting the filter, allow a certain amount of water to
flow in order to clear the pipe of any waste matter.