Product Maintenance - Nobis UNICA 10 V Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

Use and maintenance manual - Model: "UNICA 10 V/C"
It is compulsory for the system to be grounded
and have a differential switch in compliance with
legislation in force. Furthermore, ensure the socket is
compatible with the type of plug on the power
cable used.
4
MAINTENANCE
The maintenance operations, excluding routine
cleaning (explained in the relevant paragraph), must
be carried out by authorised, technical
staff. Remember, before carrying out any
maintenance operation, implement the following
precautions:
• all parts of the product must be "cold";
• ensure there is no form whatsoever of combustion
(for example ash still hot);
• use of safety devices as per the directive;
• remove the plug from the electrical socket;
• having terminated maintenance, reset the
product paying attention to re-activate all the
safety devices.
4.1 SMOKE SYSTEM MAINTENANCE
The chimney flue must always be cleaned,
since deposits of soot or fuel residue reduce
the section blocking its draught, compromising
good operation of the product and, if in large
quantities, can catch fire. It is compulsory to have
a qualified chimney sweep clean and check the
chimney flue and the stack at least once a year
or after prolonged stoppage due to non-use of the
appliance. At the end of the control/maintenance,
ask for a report to be issued stating the system is
safe.
Lack of cleaning prejudices safety
of the system.

4.2 PRODUCT MAINTENANCE

Carry out at least once a year or on each "Service
Hours" signalling (signal that appears on screen
when the working hours have been exceeded,
over which excellent product operation is not
guaranteed). In this phase, the authorised
technician should:
• completely and accurately clean the smoke
pipes;
• check the sealing status of all the gaskets;
• remove broken pellet residue inside the pellet
tank;
• re-assemble all parts of the appliance;
• check correct operation and good quality
combustion.
5
TECHNICAL DATA OF THE PRODUCT
This chapter issues to the end user all the information
relating to the technical data of the product, the
dimensions, the installation measurements, the
minimum distance to comply with from walls
and furniture, sofas, etc.
5.1 PRODUCT DATA SHEET
PRODUCT DATA SHEET
Brand
Model
Energy efficiency class
Direct thermal power (Kw)
Indirect thermal power (Kw)
Energy efficiency index
Useful efficiency (Nominal power %)
Useful efficiency (Reduced power %)
Comply with the warnings and instructions for installation
and periodic maintenance of the instructions manual.
5.2 TECHNICAL FEATURES
Model
Weight of appliance (kg)
Ø air inlet (mm)
Ø smoke outlet pipe (mm)
Vol. max. heating* (m
Power (kW)
Yield (kW)
Yield (%)
CO 13% O
(mg/m
2
Tank capacity (kg)
Pellet hourly consumption (kg/h)
Autonomy (h)
Absorbed electrical power (W)
Electrical power supply (V-Hz)
Discharge gas flow (g/s)
Minimum draught (Pa)
Smoke temperature (°C)
*This value can vary based on the type of energy
class of the home and the type of pellet used.
The data outlined are approximate and non-binding
and can vary based on the type of pellet
used. The manufacturer reserves the right
to make changes for the purpose of
12
improving product performance.
ENGLISH
EU 2015/1186
Nobis
Unica 10
A+
9.3
-
127,6
90,0
91,0
UNICA 10 V/C
Ridotto
Nominale
250
80
130
)
228
3
4,6
10,3
4,2
9,3
91,0
90,0
94,0
64,0
)
3
18,0
0,96
2,17
18,8
8,3
400
230-50
4,1
5,7
12
12
165
258