  • Page 1 EN - Installation, use and maintenance manual A8 V / C ROUND / TOP A10 V / C ROUND / TOP...
  • Page 2 Dear Customer. Thank you for choosing a product from our range. You are invited to read this manual carefully before using it, to take full advantage of all its features, in complete safety. This manual contains information necessary for correct installation, start-up, use, cleaning and maintenance of the product.
  • Page 3: Manual Index

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” 8 Menu browsing MANUAL INDEX 1 Introduction 9 First start-up instructions Symbols Date and time setting Planned use Calibration of handheld device probe 18 Improper use User/auto management Importance of the manual Ambient temperature setting General safety warnings Fireplace power setting...
  • Page 4: Importance Of The Manual

    Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” INTRODUCTION 1.3 IMPROPER USE The product by Nobis was designed and manufactured The product must be intended for the use for which it in compliance with the reference standards for the was expressly designed;...
  • Page 5: Legal Warranty

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” • The product can be used by children over • all parts resulting as being faulty due to 8 years of age and people with reduced negligence or careless use, wrong physical, sensor or mental capacity, or without maintenance, non-conforming installation experience or the necessary know-how, provided...
  • Page 6: Identification Plate

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” CHARACTERISTICS OF THE PELLETS SPARE PARTS Wood pellets are fuel made of pressed sawdust, of- Only use original spare parts. ten recovered from carpentry processing waste. The Do not wait for the components to wear from use be- material used cannot contain any foreign substance fore replacing them.
  • Page 7: Installation

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” The air intake is not necessary for INSTALLATION installation of the hermetic appliances that take air directly from outside. Check and All local and national legislation and European comply with the ventilation requirements for simul- standards must be met when installing and using the taneous operations with other combustion devices the product.
  • Page 8: Chimney Flue

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” 3.3 CHIMNEY FLUE 3.5 HERMETIC PRODUCT INSTALLATION When installing the chimney flue, the following provi- In the event of installation of a hermetic product, sions must be applied. you can execute one of the following types of con- •...
  • Page 9: Examples Of Correct Installation

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” 3.6 EXAMPLES OF CORRECT INSTALLATION installation of the product (A) necessary for the hori- zontal section for connection to an existing chimney flue. Based on a slope of 3-5%, to reduce ash deposit in the horizontal pipe section which must not be over 3m (1).
  • Page 10 Position the equipment and proceed with its connection to the chimney flue. Find, NOBIS SRL cannot be held in any way liable in the using the 4 adjustment feet, the right level so that event of non-compliance with the installation and smoke discharge and the pipe are connected start-up standards of its products.
  • Page 11: Cover Assembly

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” 3.10 COVER ASSEMBLY Remove the cast iron cover of the product, remove the black upper side panel with a 8mm hexagonal wrench and open the packaging containing the covering. LOWER SIDE MAJOLICA PANEL INSTALLATION Take the lower right side majolica from the packa- ging and insert the pins located in the lower part of...
  • Page 12: Electrical Connection

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” ASSEMBLY OF THE UPPER SIDE PANEL When finished, replace the cast iron top. Remove the panel, previously disassembled, and insert the pins located in the lower part of the panel, into the holes on the previously fixed majolica casing.
  • Page 13: Product Maintenance

    • remove the plug from the electrical socket; • having terminated maintenance, reset the prod- 5.2 TECHNICAL FEATURES uct paying attention to re-activate all the safety devices. A8V - A8C ROUND A10V - A10C ROUND Model 4.1 SMOKE SYSTEM MAINTENANCE Reduced...
  • Page 14: Product Configuration

    (STATUS) (REVISION) Società proprietaria tutela i propri diritti a rigore di legge. N0043-SPAN-E1 Via Palazzolo,11 25037 All proprietary rights reserved by NOBIS S.r.l. This drawing shall not be NOBIS S.r.l. NOBIS S.r.l. N. DISEGNO discharge Pontoglio - BS - Italy reproduced or in any way utilized for the manufacture of the component of Proprietà...
  • Page 15: Pellet Loading

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” Select the language, using the keys that you 6.2 CONFIGURATION OF T.EXT THERMOSTAT want to use as the display standard. Press the key If you want to manage the appliance from a differ- to confirm and go to the next screen.
  • Page 16: Description Of Remote Control

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” DESCRIPTION OF REMOTE CONTROL Before connection using the emergency cable, re- move the batteries from the handheld device Before switching on the appliance, you are advised from the specific compartment. DANGER OF FIRE to read the following chapter carefully relating to use of the receiver and the handheld device, 7.2 DESCRIPTION OF HANDHELD DEVICE KEYS...
  • Page 17 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” Icon indicating the status of the appliance 7.5 ICONS CONCISE DIAGRAM (see “Concise icons diagram”). MEANING Indicates the work power set. Furthermore, by pressing the scroll key , it allows the power setting SWITCH ON to be displayed, which can be edited using the two scroll keys...
  • Page 18: Menu Browsing

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” FIRST START-UP INSTRUCTIONS MENU BROWSING This chapter highlights a series of operations to carry To access the menu, press the key on the stand- out during the first start-up phase by screen to display the selection items, of the appliance.
  • Page 19 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” Scroll the items to SETTINGS with the key This setting inhibits manual management of the op- tional fan, with the exception of Access the menu by pressing key the fan setting on OFF. In this case, the appliance Scroll the items to CAL.
  • Page 20: Saving Mode

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” The appearance is highlighted of the “flame” sym- Screen in SAVING mode: bol with the writing ON, without displaying the work power. Prolonged pressing of the key accompanied by acoustic signalling causes switching off of the prod- uct, as well as resetting of any alarms.
  • Page 21 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” 10.3 POWERFUL FUNCTION Edit the value with the keys The function described in the paragraph, once acti- vated, allows heating of the ambient, taking advan- tage of the maximum speed of the fan. The scope is to supply the maximum heat to the det- riment of a minor acoustic comfort.
  • Page 22: Description Of The Menu Functions

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” OPERATING PROCEDURE 2: 10.4 VENTILATION MANAGEMENT (if optional) MENU >> SET USER >> SETTINGS >> POWERFUL The products of the range with optional ventilation, taking advantage of the natural convection system Access the menu by pressing key which guarantees a considerable amount of heat in Scroll the items to SET USER, key...
  • Page 23 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” OPERATING PROCEDURE: During editing, remember that: • to return to the previous data, without saving MENU >> SET USER >> THERMOSTAT TIMER the last data changed, press the key Access the menu by pressing key •...
  • Page 24 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” During editing, remember that: 11.3 EXTRACTION/PELLET MIX • to return to the previous data, without saving The PELLET-EXTRACTION mix setting the last data changed, press the key allows you to change, with immediate effect, the •...
  • Page 25 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” To return to the SET USER screen. 11.6 LANGUAGE press the key Based on the destination country or the user acquir- To return to the STAND-BY screen, use the ing the product, this function includes a , repeating the operation multiple times.
  • Page 26: Firmware Version

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” Edit the data highlighted using the keys Scroll the items to SETTINGS with the key Confirm the data changed using the key Access the menu by pressing key Scroll the items to ANTICONDENSA with the key To return to the STAND-BY screen, use the , repeating the operation multiple times.
  • Page 27 Access the menu by pressing key thermostat. provided on request of (not supplied). Key Nobis s.r.l. First item in the “CHANNELLING” menu, key confirm. (not supplies as standard) The screen appears with setting of channelling, If the flag is enabled for “channelling” temperature as in the figure.
  • Page 28 The screen appears with setting of channelling, of the external thermo- provided on request of as in the figure. stat. Nobis s.r.l.(not supplies as (not supplied). Key standard) confirm. Having confirmed setting of the RH channelling, confirm with the key...
  • Page 29 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” 13 PHASES CONCISE DIAGRAM PHASE DESCRIPTION - The phase starts to pre-heat the re sistor and the pellet starts to fall in the brazier. Edit the data highlighted using the keys - The pellet switches on by taking ad Confirm the data changed using the key SWITCH ON...
  • Page 30 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” ANOMALIES CONCISE DIAGRAM PHASE DESCRIPTION PHASE DESCRIPTION Management was chosen of the ambient temperature The appliance signals a malfunc- using an external thermostat (not tion of the sensor controlling correct supplied by the manufacturer) THERMOSTAT combustion.
  • Page 31: Description Of Alarms

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” DESCRIPTION OF ALARMS ALARM CODE REASON ALARM CODE REASON No power supply to the smoke extractor No power during the work phase The smoke extractor is blocked SOLUTION FAULTY SMOKE SOLUTION Press the switch off key and repeat EXTRACTOR...
  • Page 32 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” ALARM CODE REASON ALARM CODE REASON The cleaner has not completed During the pellet loading phase of the product, the tank door was not closed movement and is not found in the correct position or the fire door is not closed properly.
  • Page 33: Cleaning The Appliance

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” Each alarm condition causes the appliance to immediately switch off. Press the switch on key P3 to reset the alarm. Before switching back on the appliance, check signalling is resolved. 18 CLEANING THE APPLIANCE Before carrying out any cleaning operation on the ap- pliance, take the following precautions:...
  • Page 34: Cleaning The Glass Door

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” 18.2 CLEANING THE GLASS DOOR To clean the glass, use a cotton cloth or kitchen paper. You are advised to clean the glass using a damp cloth with water and combustion ash (with an abrasive function), avoiding use of products with additives that could, over time, wear the seals, glass and paint.
  • Page 35 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” CLEANING CYCLES TABLE OPERATING PROCEDURE: Below, the control and/or maintenance intervention Open the door positioned under the fire door, as in the figure below: are summarised which are indispensable for correct appliance operation.
  • Page 36: Wiring Diagram

    ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” 19 WIRING DIAGRAM R/RH R/RH LEGEND: SAFETY REMOTE UNIT SELECTION PRESSURE SENSOR SMOKE EXTRACTOR VACUUM SWITCH STROKE COUNTER UPGRADE FW KEY VENTILATION MANUAL RESET THERMAL MECHANICAL CLEANER (technical support only) FRONT SWITCH TERMINAL BOARD...
  • Page 37 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” MAINTENANCE DATE INTERVENTION CARRIED OUT...
  • Page 38 ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP” NOTE...
  • Page 40 NOBIS srl Via Palazzolo N.11 25037 - Pontoglio - BS www.nobisfire.it Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products without prior warning.