Product Maintenance - Nobis H17 V LIGHT Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

Use and Maintenance Manual model "H17 V LIGHT"
It is compulsory for the system to be grounded and
have a differential switch in compliance with cur-
rent laws. Also, ensure the socket is compatible with
the type of plug on the power cable used.
5
MAINTENANCE
Maintenance operations, excluding routine cleaning
(explained in the relevant paragraph), must be car-
ried out by authorized, technical staff. Remember,
before carrying out any maintenance operation, to
implement the following precautions:
• all parts of the product must be "cold";
• ensure there is no form of combustion whatsoever
(for example hot ash);
• use safety devices as per directive;
• remove the plug from the electrical socket;
• once maintenance has been carried out, reset
the product paying attention to re-activate all the
safety devices.
5.1 MAINTENANCE OF THE SMOKE SYSTEM
The chimney flue must always be kept clean,
since deposits of soot or fuel residue reduce the flow
rate, blocking the tube's draught, thus compromising
good operation of the product and, if in large quantities,
cause fire. it is mandatory to have the chimney cleaned
and checked by a qualified chimney sweep at least
once a year or after a prolonged stop for non-use of the
appliance. At the end of the check/maintenance, ask
for a report to be issued stating that the system is safe.
Failure to clean jeopardizes the safety of the system.

5.2 PRODUCT MAINTENANCE

Carry out maintenance at least once a year or on
each "Service Hours" signalling (signal appearing on
screen when the limit of working hours, over which
excellent operation is not guaranteed, have been
exceeded).
In this phase, the authorized technician should:
• completely and accurately clean the
smoke pipes;
• check the sealing status of all the gaskets;
• remove crushed pellet residue inside
the pellet tank;
• re-assemble all parts of the appliance;
• check correct operation and good quality of
combustion.
6
TECHNICAL DATA OF THE PRODUCT
This chapter gives the end user all information related
to the technical data of the product, its dimensions,
installation measurements, minimum distance to from
walls and furniture, sofas, etc. to be observed.
6.1 PRODUCT DATA SHEET
PRODUCT DATA SHEET
Brand
Model
Energy efficiency class
Direct thermal power (Kw)
Indirect thermal power (Kw)
Energy efficiency index
Useful efficiency (Nominal power %)
Useful efficiency (Reduced power %)
Comply with the warnings and instructions for installation
and periodic maintenance of the instructions manual.
6.2 TECHNICAL FEATURES
Modello
Weight of appliance (kg)
Water quantity (lt)
Min. working pressure (bar-kPa)
Max. working pressure (bar-kPa)
Ø air inlet (mm)
Ø smoke outlet pipe (mm)
Vol. max. heating* (m
)
3
Power introduced (kW)
Yield introduced (kW)
Water output power (kW)
Yield (%)
CO 13% O
(%)
2
Tank capacity (kg)
Pellet hourly consumption (kg/h)
Autonomy (h)
Absorbed electrical power (W)
Electrical power supply (V-Hz)
Discharge gas flow (g/s)
Minimum draught (Pa)
Smoke temperature (°C)
* this value can vary based on the type of energy class of the
home and the type of pellet used.
The data outlined are approximate and non-binding
and can vary based on the type of pellet
used. The manufacturer reserves the right
to make changes for the purpose of
improving product performance.
18
ENGLISH
EU 2015/1186
Nobis
H17 V LIGHT
A++
3.0
17.0
132
92.5
93.3
H17 V LIGHT
Reduced
Nominal
210
20
1 - 100
2.5 - 250
60
80
491
8.5
21.6
7.9
20.0
6.4
17.0
93.3
92.5
90
25
1.74
4.42
14.4
5.7
310
230-50
7.8
12.2
10
89
20
10
142