EN - Installation, use and maintenance manual B10 V ULISSE...
Page 2
Dear Customer. Thank you for choosing a product from our range. You are invited to read this manual carefully before using the product, so as to take full advantage of all its features in complete safety. This manual contains information necessary for correct installation, start-up, use, cleaning and maintenance of the product.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” 8 Menu browsing INDICE DEL MANUALE 9 First start-up instructions Introduction Hour-date settings Symbols Calibration of remote control probe Intended use User/auto management Improper use Room-temperature settings Importance of the manual...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” INTRODUCTION 1.3 IMPROPER USE Nobis products are designed and manufactured The product is intended to be used for the purpos- in compliance with the reference standards for es and within the limits for which it was expressly de-...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” • The product can be used by children over • all parts resulting as being faulty due to 8 years of age and people with reduced negligence or careless use, wrong...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” CHARACTERISTICS OF PELLETS SPARE PARTS Wood pellets are fuel made from pressed sawdust, Please, use only original spare parts. often recovered from carpentry processing waste. Do not wait for the components to wear from use The material used cannot contain any foreign before replacing them.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” INSTALLATION The air intake is not necessary in case of installation of hermetic appliances that take the air directly When installing and using the the product, all local, from the outside. Check and respect the ventila-...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” • it must develop mainly vertically and it must not be 3.2 SMOKE CHANNEL AND FITTINGS choked along its length; ‘Smoke channel’ is a term indicating the piping • be correctly spaced using air cavities and...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” EXAMPLES OF PROPER INSTALLATION A proper installation of the product (A) needs for a horizontal section to connect it to a pre-existing chimney flue. A slope of 3-5% must be observed, so as to reduce ash deposit in the horizontal pipe sec- tion - which must not exceed 3m in length (1).
In case the product is accessible from the outside, follow the procedure below to fix its base to the compartment surface. NOBIS SRL cannot be held in any way liable in the event of non-compliance with the installation and start-up standards of its products.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” Place the slider on the base of the compartment, making sure that the top is not inclined. Using the 4 holes on the slider, drill the top (Ø 8 mm bit). Use 4 plugs and relative M8x40 screws and washers to fix the slide;...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” ASSEMBLY: Load the pellets into the tank and close the appliance. Check that the appliance has been placed cor- rectly and safely by making sure that it is locked and cannot come off without pressing the lever (fig. 2).
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” It is compulsory for the system to be grounded and TECHNICAL DATA have a differential switch in compliance with cur- This chapter gives the end user all information related rent laws. Also, ensure the socket is compatible with to the technical data of the product, its dimensions, the type of plug on the power cable used.
Società proprietaria tutela i propri diritti a rigore di legge. N0039-IPAV recommended to both disconnect the power cable Via Palazzolo,11 25037 All proprietary rights reserved by NOBIS S.r.l. This drawing shall not be NOBIS S.r.l. Proprietà della Società NOBIS S.r.l. Senza autorizzazione scritta della N. DISEGNO...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” Select your standard language, using the keys 6.2 CONFIGURATION OF EXT. THERMOSTAT Press key to confirm and move on to the next If you want to manage the appliance from a different screen.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” DESCRIPTION OF REMOTE CONTROL Before connection using the emergency cable, remove the batteries from the remote control. FIRE HAZARD Before switching on the appliance, it is recommended to read the following chapter carefully (pertaining the use of the receiver and the remote control, as 7.2 DESCRIPTION OF REMOTE CONTROL KEYS...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” Icon indicating the status of the appliance 7.5 ICONS OVERVIEW (see “Icons Overview”). MEANING Indicates the working power set. Moreover, by pressing the scroll key , it will allow power settings to...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” FIRST START-UP INSTRUCTIONS MENU BROWSING This chapter highlights a series of operations to carry To access the menu and display all entries available, out during the first start-up phase of the appliance.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” To scroll entries to SETTINGS by pressing This setting inhibits manual management of the op- tional fan, with the exception of the fan set on OFF. Access menu by pressing In this case, the appliance will manage autonomously Scroll entries to ROOM PROBE CAL.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” A “flame” symbol with the writing ON - without dis- The screen in SAVING mode will appear as follows: playing the working power - will appear. In order to switch off the product, as well as reset alarms, keep pressed key .
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” Edit values by pressing 10.3 POWERFUL FUNCTION When powerful function is active, you can heat the room by using the fan at maximum speed. The aim is to supply the maximum heat, despite of a reduction in acoustic comfort.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” OPERATING PROCEDURE 2: 10.4 VENTILATION MANAGEMENT (not supplied with this model) MENU >> USER >> SETTINGS >> POWERFUL Products of the range equipped with optional ventila- tion take advantage of the natural convection system,...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” OPERATING PROCEDURE: While editing, remember the following: • to return to the previous data without saving MENU >> USER >> THERMOSTAT TIMER the last change, press Access menu by pressing • In case you want to change one single datum,...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” While editing, remember the following: 11.3 PELLET/AIR-INTAKE RATIO • to return to the previous data without saving The PELLET/AIR-INTAKE RATIO setting allows you to the last change, press adjust, with immediate effect, the quantity of pellets •...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” To go back to the SETTINGS screen press 11.6 LANGUAGE To go back to the STAND-BY screen, press key Depending on the country of destination or the end peatedly. user, this function includes a series of languages among which to choose.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” Scroll entries to SETTINGS by pressing key Edit highlighted data by using the keys Confirm your change by pressing the key Access menu by pressing key To go back to the STAND-BY screen, press key Scroll entries to ANTICONDENSATION, key peatedly.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” OPERATING PROCEDURE: Press the keys Press the keys enable/disable the flag if to set the MENU >> USER >> CANALIZATION you want to manage the temperature of the Access menu by pressing...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” If the PS function is not set, the fan power works independently from the product power. - TEMPERATURE it enables modulation of In the DISPLAY STATUS screen of POWERFUL function, CONTROL...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” 13 PHASES OVERVIEW PHASE DESCRIPTION - The resistor start pre-heating and pellets begin to fall in the brazier. Edit the data highlighted using the keys - Pellet ignites thanks to the heat...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” ANOMALIES OVERVIEW PHASE DESCRIPTION PHASE DESCRIPTION Room temperature management has been chosen using an external ther- The appliance signals a malfunction- mostat (not supplied by the manufac- ing of the sensor controlling prop- turer).
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” DESCRIPTION OF ALARMS ALARM CODE REASON The rotations of the smoke extractor show a Each alarm condition causes the appliance to loss of efficiency due to obstruction of immediately switch off. Press the switch on key P3 the fan or a drop in voltage.
Page 32
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” ALARM CODE REASON ALARM CODE REASON The cleaner has not completed its move- The tank door has not been closed properly ment and is not in the correct position or during pellet loading phase.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” 18 CLEANING THE APPLIANCE Product installation must take place in in such a way as to ensure easy access to the appliance itself and to the flue for cleaning and maintenance operations.
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” 18.3 CLEANING THE ASH PAN Remove the pan from the appliance and remove the ash deposited, using an ash vacuum cleaner; pay ut- most attention to the presence of embers that could still be hot and which could damage the appliance used for cleaning.
Page 35
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” TABLE OF CLEANING CYCLES Essential control and/or maintenance intervention for proper operation are summarised below. PARTS FREQUENCY 1 DD Brazier 2-3 DD Glass 1 SE Extraction pipe * 1 SE Door seal/ash pan*...
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” 19 WIRING DIAGRAM R/DX R/DX LEGEND: SAFETY REMOTE UNIT SELECTION PRESSURE SENSOR SMOKE EXTRACTOR VACUUM SWITCH STROKE COUNTER UPGRADE FW KEY MANUAL RESET THERMAL FRONT MECHANICAL CLEANER (technical support only) SWITCH VENTILATION EXT.
Page 37
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” MAINTENANCE DATE INTERVENTION CARRIED OUT...
Page 38
ENGLISH Use and Maintenance Manual model “B10 V ULISSE” NOTES...
Page 40
NOBIS srl Via Palazzolo N.11 25037 - Pontoglio - BS - Italy www.nobisfire.it Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products without prior warning.