  • Page 1 EN - Installation, use and maintenance manual UNICA 10 V/C...
  • Page 2 Dear Customer. Thank you for choosing a product from our range. You are invited to read this manual carefully before using it, to take full advantage of all its features in full safety. This manual contains information necessary for correct installation, start-up, use, cleaning and maintenance of the product.
  • Page 3 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” 8 Menu browsing INDEX 1 Introduction 9 First start-up instructions Symbols Date and time settings Intended use Calibration of room temp. probe Improper use User/auto management Importance of the manual...
  • Page 4: Importance Of The Manual

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” INTRODUCTION 1.3 IMPROPER USE The product by Nobis was designed and manufactured The product must be intended for the use for which in compliance with the reference standards for the it was expressly designed;...
  • Page 5: Legal Warranty

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” • The product can be used by children over 8 years • all parts resulting as being faulty due to negligence of age and people with reduced physical, sensor or careless use, wrong maintenance, non-conforming...
  • Page 6 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” PELLETS RECOMMENDED FEATURES SPARE PARTS Wood pellets are fuel made of pressed sawdust, of- Only use original spare parts. ten recovered from carpentry processing waste. The Do not wait for the components to wear from use be- material used cannot contain any foreign substance fore replacing them.
  • Page 7: Installation

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” The air intake is not necessary for installation of the INSTALLATION hermetic appliances that take air directly from outside. Check and comply with the ventilation All local and national legislation and European...
  • Page 8: Chimney Flue

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” 3.3 CHIMNEY FLUE 3.5 HERMETIC PRODUCT When installing the chimney flue, the following In the event of installation of a hermetic product, provisions must be applied. you can execute one of the following types of •...
  • Page 9: Examples Of Correct Installation

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” 3.6 EXAMPLES OF CORRECT INSTALLATION installation of the product (A) necessary for the horizontal section for connection to an existing chimney flue. Based on a slope of 3-5%, to reduce ash deposit in the horizontal pipe section which must not be over 3m (1).
  • Page 10 • possible instructions relating to the warranty; removing the support. • the date and signature of the installation technician; NOBIS SRL cannot be held in any way liable in the event of non-compliance with the installation and start-up standards of its products. UNPACKING THE PRODUCT...
  • Page 11: Electrical Connection

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” Remove the wooden cover (which is attached on Connect the fan using the the underside by means of magnets). Then unhook CANAL appendix, already the side panel by unscrewing the two upper fixing present in the original wiring screws.
  • Page 12: Product Maintenance

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” TECHNICAL DATA OF THE PRODUCT It is compulsory for the system to be grounded and have a differential switch in compliance with This chapter issues to the end user all the information legislation in force.
  • Page 13: Product Configuration

    Società proprietaria tutela i propri diritti a rigore di legge. N0060-SMAN-E1 Via Palazzolo,11 25037 All proprietary rights reserved by NOBIS S.r.l. This drawing shall not be Pontoglio - BS - Italy reproduced or in any way utilized for the manufacture of the component of 6.1 REMOTE CONTROL...
  • Page 14: External Thermostat

    Use and maintenance manual - Model: “UNICA 10 V/C” Select the language, using the keys that you 6.2 EXTERNAL THERMOSTAT want to use as the display standard. Press the key If you want to manage the appliance from a to confirm and go to the next screen.
  • Page 15: Description Of The Remote Control

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” DESCRIPTION OF THE REMOTE CONTROL Before connection using the emergency cable, remove the batteries from the handheld device Before switching on the appliance, you are advised from the specific compartment. DANGER OF FIRE...
  • Page 16: Flat Batteries

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” Icon indicating the status of the appliance 7.5 ICON LIST (see “Concise icons diagram”). MEANING Indicates the work power set. Furthermore, by pressing the scroll key , it allows the power setting...
  • Page 17: Menu Browsing

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” FIRST START-UP INSTRUCTIONS MENU BROWSING This chapter highlights a series of operations to carry To access the menu, press the key on the stand- out during the first start-up phase of the appliance.
  • Page 18: Room Temperature Settings

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” Scroll the items to SETTINGS with the key This setting inhibits manual management of the optional fan, with the exception of the fan setting on Access the menu by pressing key OFF.
  • Page 19: Operation

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” The appearance is highlighted of the “flame” symbol Screen in SAVING mode: with the writing ON, without displaying the work power. Long press to switch off the product and reset any alarms.
  • Page 20 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” Edit the value with the keys 10.3 POWERFUL FUNCTION The function described in the paragraph, once activated, allows heating of the ambient, taking advantage of the maximum speed of the fan.
  • Page 21: Description Of The Menu Functions

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” OPERATING PROCEDURE 2: 10.4 VENTILATION MANAGEMENT (if optional) MENU >> USER SETTINGS >> SETTINGS >> POWERFUL The products of the range with optional ventilation, taking advantage of the natural convection system...
  • Page 22 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” OPERATING PROCEDURE: During editing, remember that: • to return to the previous data, without saving MENU >> USER SETTINGS >> THERMOSTAT TIMER the last data changed, press the key Access the menu by pressing key •...
  • Page 23: Stove Status

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” During editing, remember that: 11.3 PELLET/ASPIRATION RATIO • to return to the previous data, without saving The PELLET-ASPIRATION ratio setting the last data changed, press the key allows you to change, with immediate effect, the •...
  • Page 24 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” To return to the USER SETTINGS screen. 11.6 LANGUAGE press the key Based on the destination country or the user To return to the STAND-BY screen, use the acquiring the product, this function includes a series , repeating the operation multiple times.
  • Page 25: Firmware Version

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” Edit the data highlighted using the keys Scroll the items to SETTINGS with the key Access the menu by pressing key Confirm the data changed using the key To return to the STAND-BY screen, use the Scroll the items to ANTICONDENSATION with , repeating the operation multiple times.
  • Page 26 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” OPERATING PROCEDURE: Pressing the keys Press the keys to enable/disable the to set the MENU >> USER SETTINGS >> CANALIZATION flag if you want to man- temperature of the Access the menu by pressing key...
  • Page 27 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” If the PS function is not set, the fan is always restricted by the power of the product. - ENABLE enables modulation of the In the presence of the POWERFUL function, DISPLAY...
  • Page 28: Function List

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” 13 PHASE LIST PHASE DESCRIPTION - The phase starts to pre-heat the re sistor and the pellet starts to fall in the brazier. Edit the data highlighted using the keys...
  • Page 29: Signal List

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” ANOMALY LIST PHASE DESCRIPTION PHASE DESCRIPTION Management was chosen of the ambient temperature The appliance signals a malfunc- using an external thermostat (not tion of the sensor controlling correct supplied by the manufacturer) THERMOSTAT combustion.
  • Page 30: Description Of Alarms

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” DESCRIPTION OF ALARMS ALARM CODE REASON The rotations of the smoke extractor show a Each alarm condition causes the appliance to loss of efficiency due to obstruction of immediately switch off. Press the switch on key P3 the fan or a drop in voltage.
  • Page 31 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” ALARM CODE REASON ALARM CODE REASON During the pellet loading phase of the The cleaner has not completed movement and is not found in the product, the tank door was not closed correct position or the fire door is not closed properly.
  • Page 32: Cleaning The Fireplace

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” 18.1 CLEANING THE FIREPLACE ALARM CODE REASON La botola di sicurezza si è aperta a seguito Open the fire door, using the specific blackout. tool and: • vacuum the slide bringing the ash to the brazier;...
  • Page 33: Cleaning The Glass Door

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” Lift the “cold lever”, supplied with the product, 18.2 CLEANING THE GLASS DOOR to unlock and open the fire door, as in the figure To clean the glass, use a cotton cloth or kitchen paper.
  • Page 34 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” CLEANING CYCLES: TABLE Essential control and/or maintenance interventions to be carried out for proper functioning of the appliance are summarised in the table below: PARTS/FREQUENCY TIME 7 DD Ash pan (approx. time)
  • Page 35: Wiring Diagram

    ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” 19 WIRING DIAGRAM 220V VMAN R/DX T.EXT R/DX TRANSFORMER RELAIS 220V ELECTROMAGNET 220V - 24V LEGEND: SAFETY REMOTE UNIT SELECTION PRESSURE SENSOR SMOKE EXTRACTOR VACUUM SWITCH UPGRADE FW KEY STROKE COUNTER...
  • Page 36 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” MAINTENANCE DATE INTERVENTION CARRIED OUT...
  • Page 37 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” ANNOTATIONS...
  • Page 38 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” ANNOTATIONS...
  • Page 39 ENGLISH Use and maintenance manual - Model: “UNICA 10 V/C” ANNOTATIONS...
  • Page 40 NOBIS Srl Via Palazzolo, 11 25037 - Pontoglio - BS www.nobisfire.it Nobis Srl cannot be held, in any way, liable for any errors in this manual and considers itself free to change the features of its products without prior notice.