Flow Sensor Position; Installation Of Multical® 403 Flow Sensor - Kamstrup MULTICAL 403 Installation And User Manual

Table of Contents

Advertisement

MULTICAL® 403

3.2 Flow sensor position

A Recommended position.
B Recommended position.
C Unacceptable position due to risk of air
build-up.
D Acceptable position in closed systems.
E Ought not to be placed immediately after
a valve, with the exception of block valves
(ball valve type) which must be fully open
when not used for blocking.
F Ought not to be placed immediately before
or after a pump.
G Ought not to be placed immediately after a
double bend in two planes.
In order to avoid cavitation, the back pressure at the flow sensor (the pressure at the flow sensor
outlet) must be minimum 1.5 bar at q
This applies to temperatures up to approx. 80 °C. The flow sensor must not be exposed to pressure
lower than the ambient pressure (vacuum).
3.3 Installation of MULTICAL® 403 flow sensor
The flow sensor can be mounted horizontally, vertically or at an angle.
8
E
(nominal flow) and minimum 2.5 bar at q
p
90°
90°
90°
90°
B
A
F
Kamstrup A/S • 55121739_B1_GB_02.2020
C
D
G
(maximum flow).
s