4. Louver control

4-1. Horizontal louver control

Each time the button is pressed, the airflow direction range will change as below:
• Remote controller display is not changed.
• Up/down airflow direction is set automatically as shown, in accordance with the type of operation
selected.
Cooling / Dry mode
Heating mode
• During AUTO operation, for the first a few minutes after beginning operation, airflow will be hori-
zontal 1; the air direction cannot be adjusted during this period.
The airflow direction setting will temporarily become 1 when the temperature of the airflow is low at
the start of the Heating mode.
• After beginning of AUTO/HEAT mode operated and automatic defrosting operation, the airflow will
be horizontal 1. However, the airflow direction cannot be adjusted at beginning AUTO operation
mode.

4-2. Adjust the horizontal louver

Move the horizontal louvers to adjust airflow direction you prefer.

4-3. Swing operation

• To select up/down airflow swing operation
When the swing signal is received, the horizontal louver starts to swing.
– Swinging range
• Cooling mode/dry mode/fan mode (1 to 3): 1 ↔ 4
• Heating mode/fan mode (4 to 6): 3 ↔ 6
– When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
• To select left/right airflow swing operation
No function
4-1. Horizontal louver control
Side view
1
2
3
4
5
6
1
2
3
: Horizontal flow 1
: Downward flow 6
Knob
Horizontal louver
- (04-16) -
4
5
6
4. Louver control