Fujitsu ASUH09LPAS Service Manual page 163

Wall mounted type
Hide thumbs Also See for ASUH09LPAS:
Table of Contents

Advertisement

¢ Heating thermostat on for humidifier
Situation
Example of
individual
connection
• Example of individual connection
• Operation status
The heating thermostat output for CNB01 (1-2 or 1-3 or 1- or 1-5) will be on when comp on or ex-
ternal heater on.
The heating thermostat output will be off when comp off and external heater off.
2-4. Details of function
Function
setting
Mode
Heating
thermostat on
no. 60
5
60-05
6
60-06
7
60-07
8
60-08
External output: Heating thermostat on
On
Heating operation
Off
On
Heating thermostat
On output
Off
On
Comp. On / Off
Off
On
External heater
output On / Off
Off
On
Fan
Off
Indoor unit
Rotary SW
7
8
9
A
Humidifier
Cool air prevention
- (05-39) -
External output
Indoor unit fan
Heating
operation
thermostat on
status
CN47
CN312
Not used
CN311
CN310
2. External input and output

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asuh12lpasAouh09lpas1Aouh12lpas1

Table of Contents