• Limit of maximum speed based on outdoor temperature
Model name
ASUH09LPAS
ASUH12LPAS
1-1. Cooling operation
Outdoor
temperature drops
A zone
93.2°F
(34°C)
B zone
86.0°F
(30°C)
C zone
66.2°F
(19°C)
D zone
50.0°F
(10°C)
E zone
32.0°F
(0°C)
F zone
Outdoor
temperature zone
A zone
B zone
C zone
D zone
E zone
F zone
A zone
B zone
C zone
D zone
E zone
F zone
- (04-2) -
Outdoor
temperature rises
96.8°F
(36°C)
89.6°F
(32°C)
69.8°F
(21°C)
53.6°F
(12°C)
35.6°F
(2°C)
Indoor unit fan mode
HIGH
MED
90
49
90
49
90
49
60
44
60
44
60
44
89
47
89
47
89
47
54
42
54
42
54
42
Unit: rps
LOW
QUIET
34
24
34
24
34
24
34
24
34
24
34
24
36
26
36
26
36
26
34
26
34
26
34
26
1. Rotation number control of compressor