• Output power:
• Connectors:
◦ Ethernet/PoE:
◦ Power connector:
• Handset
◦ Battery type:
◦ Talk time:
◦ Standby time:
◦ Charging time:
• Charger: Input 5VDC 1000mA, integrated cable and USB
type A plug
• Power
◦ Handset charger: SMPS power adapter Ten Pao, input
100-240 VAC, output 5V DC 1000 mA, 5W (included in
delivery), USB type A jack
- EU: model S005CAV0500100
- U.S.: model S005CAU0500100S
- AU: model S005CAS0500100
- UK: model S005CAB0500100
◦ Base station: Power over Ethernet (PoE): IEEE 802.3,
Class 2, 10/100 Base-T interface. If PoE is not available,
a power adapter can be ordered separately:
- Mass Power, model NBS12E050200UV, Snom PN
00004570, or
- Rongweixin, model R122-0502000ID, Snom PN
00004571
Additional important information USA
FCC ID M400 base station: T7HX9431
FCC ID M30 handset: T7HCT8436
Intended use
The handset is designed for use with a Snom M-series
base. The base is designed for use with a Snom M-series
handset. Any other use, modification or reconstruction of
the product is considered unintended use.

Important Safety Information

Follow all instructions and warnings in the user manual,
and on the equipment to prevent accidents.
WARNING
Fire, electric shock, or other injury may result if you do not
observe the following safety precautions:
• Do not use in or near a bathtub, sink, swimming pool, wet
basement, or other water.
EU < 250 mW, USA < 140 mW
RJ45 (8P8C)
Coaxial, 5V DC
Rechargeable Lithium-Ion,
1100mAH, 3.7 V, 4.1 Wh
Approx. 22 hours
Approx. 350 hours
From empty to full up to 6 hours
• Do not use this or any cordless telephone in the vicinity
of a gas leak.
• Do not use in environments subject to explosion hazards,
such as auto paint shops.
• Do not use near medical equipment or if you have a
pacemaker.
• Unplug from wall outlet before cleaning.
• To prevent overheating, do not block slots and openings
in the cabinet or the back or bottom of equipment. Do not
place equipment on beds, sofas, rugs, or other surfaces
that generate fibers.
• To prevent overheating, do not place near or over a
radiator or in a cabinet without properventilation.
• To reduce the risk of fire, use only 26 AWG or larger UL-
listed or CSA-certified telecommunication line cord.
• Operate using the power source indicated on the marking
label. If you are unsure about the type of power supply to
your home or business, consult your power company.
• Do not place objects on the power cord. Do not step on
the power cord.
• To prevent exposure to dangerous voltage, do not push
objects through cabinet slots.
• To reduce the risk of electric shock, do not disassemble
equipment or open parts other than specified access
doors. Opening or removing parts may expose you to
dangerous voltage or other risks. Incorrect reassembly
can cause electric shock when equipment is subsequently
used.
• Do not overload wall outlets and extension cords.
• Unplug equipment and contact qualified service if any of
the following has occurred:
◦ Power supply cord or plug has been damaged or
frayed.
◦ Liquid has been spilled on or in the equipment.
◦ Equipment has been exposed to rain or water.
◦ Equipment does not work normally even when the
operating instructions are followed. Adjust only those
controls referred to in the operating instructions.
Improper adjustment of other controls may result
in damage and may require extensive work by an
authorized service center.
◦ Equipment has been dropped and damaged.
◦ Equipment has exhibited a distinct change in
performance.
• Do not put the handset of the telephone next to your ear
when the handset is not in normal talk mode.
• Radio signals transmitted between the handset and base
may cause interference with hearing aids.
• WARNING: The handset contains magnets and the
earpiece or mouthpiece may attract and hold small
dangerous objects such as pins. Please ensure no such
objects are present before each use.