Operation
b) When the ambient temperature reaches the set temperature, the heating wire
turns off, the vane delays 10 seconds before turning off, oscillation stops (if it
has been turned on before), and others remain unchanged. When the ambient
temperature drops 2°C below the set temperature, the heating wire, vane and
oscillating function (if they have been turned on before) turn on again. (For example:
If the temperature is set to 22°C, the heating wire will turn off, oscillation will stop
(if it has been turned on before), and other displays remain unchanged when the
ambient temperature reaches 22°C. When the ambient temperature drops to 20°C,
the heating wire, vane and oscillation (if they have been turned on before) turn on
again.
c) In non-ECO mode (if available), you can press the cooling air speed button
(3)
to exit the heating air function but the set temperature will be memorised (the LED
display does not display the set temperature).
After the temperature and timer is set, the current set working temperature and
remaining working time will be displayed alternately every 10 seconds.
HEATING AIR SPEED
a) The heating function is not active when the device is turned on for the first time.
Press the Heating Air Speed button
(4)
to turn on the heating function. Press it
for the first time to turn on the low-level heating air, the low-level heating indicator
lights up and the low-level heating air runs at level 2 speed.
b) Press the Heating Air Speed button
(4)
again to turn on the high level heating
air, the high level heater indicator lights up, and the high level heating wire switches
on after 10 seconds (when the high level heating air is turned on, it will run at level
2 speed immediately, and the high level heating wire delays 10 seconds before
switching on).
c) The ECO mode is turned on when the Heating Air Speed button
(4)
is pressed
for the third time, and the ECO indicator light comes on. The operating rules of ECO
mode are as follows:
1) The default setting temperature is 25°C and 18°C. When the ambient temperature
is lower than 18°C, the heating wire runs at the high level. When the ambient
temperature is equal to or greater than 18°C and lower than 25°C, the heating wire
runs at the low level. When the ambient temperature is equal to or greater than
25°C, the heating wire turns off.
2) After the ECO mode is turned on, the heating wire turns off when the ambient
temperature rises to 25°C, the vane turns off after a delay of 10 seconds, and
oscillation stops (if it has been turned on before). Others remain unchanged, when
the ambient temperature drops 2°C lower than the set temperature (that is, 23°C),
the heating wire, vane and oscillation (if they have been turned on before) turn on
again.