1st button – controls 2nd and 3rd group:
•
Click – alternately ON with last level / OFF,
•
2xClick – send pre-set level (set in parameter 152),
•
Hold – alternately increasing/decreasing level until released.
2nd button – controls 4th and 5th group:
•
Click – alternately ON with last level / OFF,
•
2xClick – send pre-set level (set in parameter 153),
•
Hold – alternately increasing/decreasing level until released.
Single Button
This mode is enabled by setting parameter 20 to 2.
In this mode the device works as one logical button and it uses asso-
ciations to control other Z-Wave devices (groups 2-3). You can con-
trol multiple devices of different type in this mode.
1st and 2nd button work in the same way:
•
Click – alternately ON with last level / OFF,
•
2xClick – send pre-set level (set in parameter 152),
•
Hold – alternately increasing/decreasing level until released.
Switch Controller
This mode is enabled by setting parameter 20 to 3.
In this mode the device uses associations to control Z-Wave binary
switches (group 6).
•
Click 1st – ON,
•
Click 2nd – OFF.
Dimmer / Roller Shutter Controller
This mode is enabled by setting parameter 20 to 4.
In this mode the device uses associations to control Z-Wave dimmers
and rollers shutters (group 6).
1st button – turns ON and increases level:
•
Click – ON with last level,
•
Hold – increasing level until released,
•
2xClick – send pre-set level (set in parameter 152).
2nd button – turns OFF and decreases level:
•
Click – OFF,
•
Hold – decreasing level until released.
13
operatIon