This symbol indicates information that if ignored, could result in personal CAUTION injury or physical damage due to incorrect handling. PLEASE NOTE Indicates information that is considered important, but not hazard-related. MAX | User Manual...
1.3. Safety Instructions WARNING HIGH LIFE RISK DUE TO FIRE OR ELECTROCUTION. The Sunsynk Max can only be installed by a qualified licensed electrical contractor. This is not a DIY product. Be sure to read this manual thoroughly before installation. ...
2. PRODUCT INTRODUCTION The Sunsynk MAX is the most powerful low-voltage inverter in the world, achieving a maxium output power of 16kW and battery charge current of 300A. This power management tool allows the user to hit those ‘par- ity’ targets by managing power-flow from multiple sources such as solar, mains power (grid) and generators, and then effectively storing and releasing power as and when utilities require.
Page 8
2. LCD Display 7. Parallel port 12. Generator input 3. Function Buttons 8. Battery input connectors 13. Load 4. DC Switch 9. Functon Port 14. Grid 5. Power on/off button 10. Battery(CANBus) Port 15. WiFi Interface MAX | User Manual...
Consult with your system integrator for other possible system architectures depending on your require- ments. This inverter can power all kinds of appliances in home or once environment, including motor type applianc- es such as refrigerator and air conditioner. MAX | User Manual...
Max. Discharge Current 300A Charging Curve 3 Stages/Equalisation External Temperature Sensor Charging Strategy for Li-Ion Self-Adaptation to BMS Battery PV String Input Data Max. DC Input Power 18000W Max PV Input Voltage 450V MPPT Range 250V~450V Start-up Voltage 150V PV Input Current 22A + 22A + 22A Max.
Page 12
General Data Operating Temperature -25~55°C Range Cooling Noise <30dB Communication with BMS RS485; CAN Weight 34.5kg Size 422W×702H×281D mm Protection Degree IP65 Installation Style Wall-mounted Warranty 5 years MAX | User Manual...
4. INSTALLATION 4.1. Parts List Check the equipment before installation. Please make sure nothing is damaged in the package. You should have received the items in the following package: MAX | User Manual...
4.2. Selecting the Mounting Area This Sunsynk MAX is designed for outdoor use (IP65). DO NOT install the inverter in the following areas: Areas with high salt content, such as the marine environment. It will deteriorate the metal parts and pos- ...
Be sure to keep other objects and surfaces as shown in the figure to guarantee sufficient heat dissipa- tion and have enough space to remove wires. For proper air circulation to dissipate heat, allow a clearance of approximately 50cm to the side and 100cm to the front. MAX | User Manual...
Page 16
1. Use a proper hammer to fit the expansion bolt into the holes. 2. Carry the inverter and holding it, make sure the hanger aim at the expansion bolt,fix the inverter on the wall. 3. Fasten the screw head of the expansion bolt to finish the mountng. MAX | User Manual...
Reverse Polarity. Before making the final DC connection or closing DC breaker/disconnect, be sure positive(+) must be connect to positive(+) and negative(-) must be connected to negative(-). Reverse polarity connection on battery will damage the inverter. MAX | User Manual...
All wiring/connecting must be performed by qualified personnel. Before making the final DC con- nection or closing the DC Breaker/disconnection device, ensure the inverter unit is wired correctly. A reverse-polarity connection on the battery will damage the inverter. 4.6.1. Recommended DC Battery Protection MAX | User Manual...
To verify if the battery is communicating, access the Li BMS menu as detailed in the section ‘Setting Up a Lithium Battery’ and check whether the values are realistic. It is important that the charge and discharge limits in that page match the numbers expected for the number of batteries physically con- nected. MAX | User Manual...
AC breaker between backup load and inverter.This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current. For the Sunsynk MAX model, the recommended AC breaker for backup load is 200AC.
4.10. Installing the CT Coil The CT coil is one of the most important parts of the Sunsynk Max. This device reduces the power of the inverter to prevent feeding power to the grid. This feature is also known as “Zero Export”.
Since the inverter is a true hybrid, then the bond must only be made when the inverter is operating in Island- ing Mode. To accommodate this, Sunsynk provides an AC output, which is connected to the A/T/S connec- tions whenever the inverter is running on Island Mode. Therefore, you can simply connect the coil of an AC relay to the ATS 240 connections.
PLEASE NOTE The grid power may still be present, but the inverter is not draining power from it since the unit is working in ‘Island Mode’. 4.12. Meter Connection 4.12.1. System Connection for the CHNT Meter MAX | User Manual...
10AWG The correct steps in assembling the DC connector are explained below: 1. Strip 7mm of the plastic coating off the DC wire and disassemble the connector cap nut. 2. Crimp metal terminals with crimping pliers. MAX | User Manual...
2. Insert the contact pin into the connector housing until it locks into place. Then screw the cap nut onto the connector housing. Torque to 2.5-3 N.m. 4. Finally, insert the DC connector into the positive and negative input of the inverter. 4.15. PV Protection MAX | User Manual...
When the system is connected without a battery but connected with either PV or grid and the ON/OFF but- ton is switched off, the LCD will still illuminate (display will show off). In this condition, when switching on the ON/OFF button and selecting ‘No Battery’, the system can still work. MAX | User Manual...
Real-time solar power in (kW). Access the fault diagnostic page. Real-time load power in (kW). 5.4. Status Page To access the Status page, click on the BATTERY or AC LOAD dial on the Home page. MAX | User Manual...
(programmable), the battery power is fed into the inverter. 3. The inverter can then supply power to the grid (export or no export), load, and auxiliary or smart load. 4. CT coil controls the export power. MAX | User Manual...
Time, Date, and MCU. BATTERY IN/OUT MPPT. GRID. Battery Grid What you can do from this page: Access the Basic Setup Page (press the BASIC icon). Access the Battery Setup Page (press the BATTERY icon). MAX | User Manual...
Noms des installateurs. Ce que vous pouvez faire depuis cette page: Configurez le nom de votre entreprise. Allumez ou éteignez le bip. Réglez le rétroéclairage de l'écran LCD sur la luminosité automatique. MAX | User Manual...
*Before performing a successful ‘Factory Reset’ and locking the systems, the user must enter a pass- word to allow the setting to take place. The password for ‘Factory Reset’ is 9999 and for lockout is 7777. MAX | User Manual...
Max battery charge current (Amps). Max battery discharge current (Amps) should be 20% of the Ah rating for AGM only. For Lithium, please refer to the battery manufacturer's documentation. Note: This is a global max. Discharge current for both ‘grid-tied’...
Tick ‘Gen Charge’ to charge the batteries from the gen I/P. Tick ‘Grid Charge’ to charge the batteries from the grid I/P. Tick ‘Gen Signal’ signal to auto-switch a relay box. Tick ‘Grid Signal’ signal to auto-switch a relay box. MAX | User Manual...
Page 41
Gen Signal: Normally open (NO) relay that closes when the Gen Start signal state is active. Gen Max Run Time: This indicates the longest time the generator can run in one day. When the maximum running time is reached, the generator will be turned off. ‘24H’ means the generator will run continuously.
5.12. Battery Discharge Page To configure inverter’s shutdown settings, click on the BATTERY icon and then on ‘Shut Down’. MAX | User Manual...
Page 43
Activating Shutdown causes the inverter to enter standby-mode. It does not entirely shut down the inverter. Total shutdown occurs at voltages below 19V. The voltage displayed on the Sunsynk Parity Inverter will vary depending on whether the inverter is charging or discharging the batteries.
The batteries recommended for use with the Sunsynk systems are AGM Lead Acid or Lithium Battery Banks. (‘AGM’ means Absorbed Glass Matt construction that allows the electrolyte to be suspended new the plate’s active material. In theory, this enhances both the discharge and recharging efficiency. AGM batteries are very heavy as a result).
Page 45
PLEASE NOTE With some types of lithium battery, the BMS cannot be controlled by the Sunsynk inverter. In this case, treat the battery as a lead-acid type and set the charging and discharging protocol following the bat- tery manufacturer specification.
Page 46
ESS-BOX2 GenixGreen RS485 ESS-BOX3 RS485 ESS-BOX4 RS485 H4850M Sunwoda RS485 V-LFP51.2V100Ah-5KW VISION Group VLFP51.2V200Ah-5KW M4856-P Alpha Ess SMILE BAT GSL051100A-B-GBP2 GSL051200A-B-GBP2 GSL051280A-B-GBP2 GSL ENERGY ZnP48100ESA1 GSL-51-100 GSL-51-200 TB51100F-T110 TOPBAND TB51120-T110 MAX | User Manual...
Page 47
1001 - E016 SUNB-5.0-C01-48-PC Deye SUNB-5.0-E01-48-PC SUNB-5.0-G01-48-PC Uhome-LFP 5000 AOBOET Uhome-LFP 2400 Wattsonic Li-LV battery series KODAK FL5.2 Fox ess LD-48100P RS485 PYTES E-BOX 48100R Energy MD48-100 MD48-50 Highstart HSD4870 Rosen Solar LFP48V200AH Energy MAX | User Manual...
Page 48
Blue Nova HC Manual-HC_v102.pdf BN52V-840-43.6K HC BN52V-1120-58.2K HC CANH = Pin 7 BN52V-1400-72.8K HC CANL = Pin 8 BlueNova-BMAC-Manu- BN52V-840-43.6K BR Blue Nova al-v4.pdf Rack Series BN52V-1120-58.2K BR RacPower BN52-100-5.2K Blue Nova Rackpower RacPower BN52-100-5.2K MAX | User Manual...
Set the unit to charge the battery from the grid or generator ticking ‘Grid’ or ‘Gen’ and set what times this needs to occur. Set the time to discharge the unit to the load or export to the grid by unticking ‘Grid’ and ‘Gen’. MAX | User Manual...
Page 50
If the ‘Use Timer’ function is activated then the inverter will use the battery power according to your settings when the Grid is present. If this function is not set, the batteries WILL ONLY be used for backup when there is no utility grid power. MAX | User Manual...
The power produced is supplying the ‘Non-Essential Load’ while the inverter is set at a maximum power of 8kW (Max Sell Power). The inverter is connected to the grid, but no export is performed. The unit allows small amounts of power to flow from the Grid (100W Zero Export Power) to prevent any back-flow. In this example, the solar PV is prioritised to supply the Load first and then subsequently, charge the battery.
This can be selected under advance settings. This can be selected under advance settings. 1. DRM 1/5 2. DRM 2/6 3. DRM 3/7 4. RDRM 4/8 5. Ref 0 6. D Ground 7. Net J 4-7 8. Net J 4-7 MAX | User Manual...
Set the Modbus SN for paralleling. The Sunsynk parity inverter can be wired standalone or where more power is required it can be connected in parallel either single or 3 phase configuration. The maximum number of inverters that can be paral- leled in a single phase utility grid is 16 and the maximum number that can be paralleled in a three phase utility grid is 15.
Page 54
The grid input can also be connected in parallel. You cannot connect the Aux/Gen port in parallel, because this causes a conflict between the fre- quency of the generator and the frequency of the grid. MAX | User Manual...
Page 55
If you need further help please refer to the Sunsynk website where you will find training videos and Fre- quently Asked Questions www.sunsynk.com. Firmware prior installation is important to be updated and all inverters in parallel or three phase system must be the same.
5.19. Grid Power This page shows the Daily / Monthly / Yearly and total grid power export or consumed. Access this page by clicking on the ‘Solar/Turbine’ icon on the home page. TOTAL System Grid Power: Total MAX | User Manual...
This can cause the turbine to speed up dramatically, which can be very dangerous and usually happens suddenly. Thus, it is essential to use a self-breaking turbine. Voltage (V) Max. Current (A) Power (W) 23.33 3500 17.50 3500 14.00 3500 11.67 3500 8.75 3500 MAX | User Manual...
A nice feature of this page is that when the batteries are full and the inverter is still producing power from the solar PV or turbine, it is possible to direct the power generated to another load such as a water heater. MAX | User Manual...
Peak Shaving: This is a technique used to reduce electrical power consumption during periods of maximum demand on the utility grid. This enables the user to save substantial amounts of money due to the expensive peak power charges. MAX | User Manual...
1.Check if PV module and battery connections. ware 2.Reset the system. Leakage current fault 1.Check the PV module and inverter cables. AC leakage cur- rent is trans over 2.You may have a faulty PV panel (earth short) current 3.Restart inverter MAX | User Manual...
Page 61
3. Check the battery BMS Important: Especially with Lithium batteries, ensure that the bat- teries Max. discharge current or power specification is the same or higher than the inverter specification. Heat Sink temp is too high Heat sink high-tem- 1.Check if the working environment temperature is too high.
Page 62
Chapter 3 ‘Technical Specifications’. If you need further help please refer to the Sunsynk website where you will find training videos and frequent- ly asked questions www.sunsynk.com.
3. Switch on Battery and battery breaker 4. Switch on the DC (PV Isolator) Shutdown Sequence: 1. Switch off AC 2. Press the start button 3. Switch off the battery and the battery breaker 4. Switch off the DC (PV isolator) MAX | User Manual...
AC Load, in 3 tems, and wind turbine the correct limiting resis- Phase the output volt- tor, caps and rectifier age will increase across phase to 400V Familiarize yourself with common fault codes MAX | User Manual...
Page 69
APPENDIX B Inverters sold in Australia will be set to the Default Australian standards APPENDIX C The Sunsynk Max is compatible with the SolarMan app, via a Wifi or GSM data logger (See SolarMan instruc- tion manual). APPENDIX D If an external Residual Current Device (RCD) is used it should be of Type A/AC with a tripping current of 30mA or higher.
Page 70
Instantaneous APPENDIX E The Sunsynk inverter can be connected to the internet, but you need to add a data logger to do this. The inverter is compatible with Solar Man data-loggers, which you can obtain from us with your distributor 1.