Campbell 092 Instruction Manual

Campbell 092 Instruction Manual

Barometric pressure sensor

Advertisement

Quick Links

Model 092
Barometric Pressure Sensor
6/12
C o p y r i g h t
©
2 0 1 2
C a m p b e l l
S c i e n t i f i c ,
I n c .

Advertisement

Table of Contents
loading

Summary of Contents for Campbell 092

  • Page 1 Model 092 Barometric Pressure Sensor 6/12 C o p y r i g h t © 2 0 1 2 C a m p b e l l S c i e n t i f i c , I n c .
  • Page 3: Warranty

    Campbell pricelist or product manual. Products not manufactured, but that are re-sold by Campbell, are warranted only to the limits extended by the original manufacturer. Batteries, fine-wire thermocouples, desiccant, and other consumables have no warranty.
  • Page 4 SCIENTIFIC, INC., phone (435) 227-9000. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. Campbell Scientific's shipping address is: CAMPBELL SCIENTIFIC, INC.
  • Page 5 7.2 Wiring.......................8 7.3 Programming ....................8 8. Maintenance ..............9 8.1 Cleaning....................9 8.2 Calibration ....................9 Appendices A. Analog Output Configurations....... A-1 B. Wiring ............... B-1 C. CE Certification ............C-1 Figures 4-1. 092 installed on a vertical mast ...............2 B-1. Analog wiring ..................B-1...
  • Page 6 092 Table of Contents Tables 7-1. Connecting the 092 to Campbell Scientific Dataloggers......8 A-1. Dip Switches SW1: Analog Output Voltage Settings......A-1 A-2. Dip Switches SW2: Analog Output Pressure Range Settings ... A-2...
  • Page 7: Cautionary Statements

    Please review Section 7, Installation for complete guidelines. To install the 092: 1. The 092 enclosure is pre-supplied with desiccant and does not need to be opened. 2. Attach the 092 to the tripod or tower leg using the supplied U-bolts.
  • Page 8 Model 092 Barometric Pressure Sensor FIGURE 4-1. 092 installed on a vertical mast Individual wire leads connect to the CR1000 datalogger as shown in step 5 of the procedure in Section 4.2, Programming with Short Cut. A more generalized wiring diagram is provided in Section 7.2, Wiring.
  • Page 9 4.2 Programming with Short Cut Short Cut Program Generator for Windows can be used to program the CR1000 datalogger to measure the 092 as outlined in the following procedure. Short Cut can also program other 092 compatible Campbell Scientific dataloggers.
  • Page 10 Model 092 Barometric Pressure Sensor 3. Select 092 Barometric Pressure Sensor and click the right arrow to add it to the list of sensors to be measured. 4. Define the name of the public variable, or use the default BP_mmHg to hold the barometric pressure measurement.
  • Page 11 Model 092 Barometric Pressure Sensor 5. Sensor connections to the CR1000 datalogger are shown in the Wiring tab. 6. Select the desired output data for final storage and click Finish. 7. Click Wiring Diagram for a description of sensor wiring for this example.
  • Page 12 NOTE the 092 with the top cover of the polycarbonate case off. All wiring terminals on the 092 are protected from static surge damage by transzorbs and current limiting resistors. Although the 092 is configured at Campbell Scientific for analog output, digital output options including RS-232 and SDI-12 are available.
  • Page 13: Specifications

    7. Installation 7.1 Mounting The 092 is factory mounted to a solar shield. The solar shield mounts by way of two U-bolts to a vertical pipe with diameter up to 2” IPS. Install the sensor such that it faces North in the Northern Hemisphere, or South in the Southern Hemisphere.
  • Page 14 Model 092 Barometric Pressure Sensor 7.2 Wiring TABLE 7-1. Connecting the 092 to Campbell Scientific Dataloggers Wire Color Wire Description CR23X CR10(X) CR800-series CR500 CR1000 CR510 CR3000 CR5000 Terminal Terminal Power 12V White Signal SE Input SE Input Black Ground...
  • Page 15 'Main Program BeginProg 'Main Scan Scan(5,Sec,1,0) 'Default Datalogger Battery Voltage measurement 'BattV' Battery(BattV) 'Default Wiring Panel Temperature measurement 'PTemp_C' PanelTemp(PTemp_C,_60Hz) '092 Barometric Pressure Sensor measurement 'BP_mmHg' VoltSE(BP_mmHg,1,mV5000,1,1,0,_60Hz,0.1,600) BP_mmHg=BP_mmHg*0.75006 'Call Data Tables and Store Data CallTable(Table1) CallTable(Table2) NextScan EndProg 8. Maintenance 8.1 Cleaning...
  • Page 16 Model 092 Barometric Pressure Sensor...
  • Page 17: Appendix A. Analog Output Configurations

    Tables A-1 and A-2. Highlighted settings are those set at the factory by Campbell Scientific, Inc. Complete information concerning measurement, output, and communications settings is available in the Met One 092, 594, 6633A Barometric Pressure Sensor Manual, which is available at www.campbellsci.com. TABLE A-1. Dip Switches SW1:...
  • Page 18 26.58 32.48 Factory configuration at Campbell Scientific, Inc. Settings with no pressure values are invalid settings. If the switches are set to either of these combinations, the analog output will default to the full range of 600 to 1100 mbar.
  • Page 19: Appendix B. Wiring

    Appendix B. Wiring The 092 ships from Campbell Scientific pre-wired for analog output. Internal cable connections are shown in Figure B-1. FIGURE B-1. Analog wiring...
  • Page 20 Appendix B. Wiring...
  • Page 21: Appendix C. Ce Certification

    Appendix C. CE Certification...
  • Page 22 Appendix C. CE Certification...
  • Page 24 Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za • cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA)

Table of Contents