AVHC & Dashboard:
Vernon Tool MasterPipe Compact Profiler
IHS (Initial Height Sense): This setting turns OHMIC Detection on or off:
On - The head will detect material when the ohmic cap comes
into contact with the grounded, conductive material on the
table. Once detected the head will retract to the transfer
height setting.
Off - The head will move to top of material setting (Job Setup)
and retract to transfer height.
RESET Z POSITION:
Resets the Z lifter to its Zero Position by moving the head to its upper
stroke and re-establishing its zero position.
Dashboard:
The dashboard displays the host indicators and tools for the operator:
Arc Voltage - Displays Arc Voltage feedback from the
plasma during cutting.
Plasma Pierce Count - This is used for keeping track of how
many pierces the plasma consumables make. You will
RESET every time you change the consumables.
Process - This displays the current cutting process.
Feedrate - This displays the feedrate override %.
X, Y, Z - This shows the torch coordinates relative to the
machine space.
OK to Move - Indicates when the plasma has pierced through
the material and is ready to start the program.
IHS - Indicates when the material is detected via OHMIC.
Breakaway - Indicates if the breakaway circuit is open/closed.