Led Status Codes; Trends - Victron energy SmartShunt IP65 Manual

Battery monitor
Hide thumbs Also See for SmartShunt IP65:
Table of Contents

Advertisement

as it is a momentary readout and should be used as a guideline only. We recommend the use of the state of charge readout for
accurate battery monitoring.
If the "Time remaining" indicates three dashes: "---" this means that the battery monitor is in an unsynchronised state. This
occurs when the battery monitor has just been installed or after it has been left unpowered and is powered up again. For more
information, see see the
Synchronising the battery monitor [16]
Input
This is the state of the auxiliary input. Depending on how the battery monitor has been set up, you will see one of these options:
• Starter battery voltage: This shows the voltage of a second battery.
• Battery temperature: This shows the battery temperature of the main battery when the optional temperature sensor is used.
• Midpoint voltage deviation: This shows the deviation in a percentage of the main voltage of the battery bank top section
compared to the voltage of the bottom section. For more information on this feature see the
chapter.

5.3. LED status codes

Both battery monitor LEDs are associated with the Bluetooth interface.
• On power-up, the blue LED will blink, and the red LED will quickly flash. The red LED will give a short flash to confirm that the
red LED is functional.
• When the blue LED is blinking, the Bluetooth interface is ready to be connected to the VictronConnect app.
• When the blue LED stays on, the Bluetooth interface has successfully connected to VictronConnect app via Bluetooth.
See below table for an overview of all possible LED combinations of the Bluetooth module and their meaning.
Blue LED
RED LED
Slow blinking
On
On
Slow blinking
Slow blinking
Double flash
Double flash
Fast blinking and
Fast blinking and
alternating with
alternating with
red LED
blue LED
On
Fast blinking
On
Slow blinking

5.4. Trends

The VictronConnect app provides battery monitor data logging. Providing that the firmware battery monitor is up to date, the
battery monitor will store up to 45 days of past data and two of the following parameters can be viewed alongside:
• Voltage (V).
• Current (A).
• Power (W).
• Consumed Amp Hours (Ah).
• State of charge (%).
• Temperature (°C).
Page 13
Manual - SmartShunt IP65
chapter.
Operational state
Off
VE.Direct gateway
Off
VE.Direct gateway
On
VE.Direct gateway
VE.Direct gateway
VE.Direct gateway
Firmware update
Firmware update
Firmware update
Midpoint voltage monitoring [32]
Connection state
Ready for connection via
Not connected
Bluetooth
Bluetooth successfully
Connected
connected
VE.Direct communication
Connected
problem
VE.Direct communication
Not connected
problem
Confirmation that the PIN code
Not connected
has been cleared
The firmware needs to be
Not connected
updated
Connected
The firmware is being updated
Programming
The firmware is being updated
Description
Operation

Hide quick links:

Advertisement

Table of Contents
loading