Nordson Vulcan Jet Customer Product Manual
Nordson Vulcan Jet Customer Product Manual

Nordson Vulcan Jet Customer Product Manual

Dispensing system
Table of Contents

Advertisement

Quick Links

Vulcan Jet Dispensing System
Customer Product Manual
Part 1126187_05
Issued 09/21
This document contains important safety information.
Be sure to read and follow all safety information in this
document and any other related documentation.
NORDSON CORPORATION  DULUTH, GEORGIA  USA
www.nordson.com

Advertisement

Table of Contents
loading

Summary of Contents for Nordson Vulcan Jet

  • Page 1 Vulcan Jet Dispensing System Customer Product Manual Part 1126187_05 Issued 09/21 This document contains important safety information. Be sure to read and follow all safety information in this document and any other related documentation. NORDSON CORPORATION  DULUTH, GEORGIA  USA www.nordson.com...
  • Page 2 Vention Medical Advancing Your Innovations For Health, VersaBlue, VersaDrum, VersaPail, VersaPUR, Versa‐Spray, Versatility, Vortix, VP Big 10pt - 3D Design, VP stylized, When you expect more., X-Plane, and YesTech are registered trademarks of Nordson Corporation. Accubar, Active Nozzle, Advanced Plasma Systems, AeroDeck, AeroWash, AirShield, AltaBlue, AltaSlot, AltaSpray, ATS, Auto‐Flo,...
  • Page 3: Table Of Contents

    ........3‐2 Vulcan Jet Controller Hardware Installation Overview ....
  • Page 4 What's Being Saved in a Recipe ......5‐16 E 2021 Nordson Corporation Part 1126187_05...
  • Page 5 ..........6-42 Part 1126187_05 E 2021 Nordson Corporation...
  • Page 6 ......9‐1 Vulcan Jet Dispensing System Assemblies ..... . .
  • Page 7: Safety

    CAUTION! (Used without the safety alert symbol) Indicates a potentially hazardous situation that, if not avoided, can result in damage to equipment or property. Issued 9-17 E 2021 Nordson Corporation Part 1126187_05...
  • Page 8: Responsibilities Of The Equipment Owner

    Provide appropriate emergency and first aid equipment. Conduct safety inspections to ensure required practices are being followed. Re‐evaluate safety practices and procedures whenever changes are made to the process or equipment. Issued 9−17 E 2021 Nordson Corporation Part 1126187_05...
  • Page 9: User Qualifications

    Do not modify the equipment. Do not use incompatible materials or unapproved auxiliary devices. Contact your Nordson representative if you have any questions on material compatibility or the use of non‐standard auxiliary devices. Issued 9-17 E 2021 Nordson Corporation...
  • Page 10: Instructions And Safety Messages

    Familiarize yourself with the location and meaning of the safety warning labels and tags affixed to the equipment. Refer to Safety Labels and Tags at the end of this section. If you are unsure of how to use the equipment, contact your Nordson representative for assistance. Installation Practices Install the equipment in accordance with the instructions provided in this document and in the documentation provided with auxiliary devices.
  • Page 11: Operating Practices

    Read and comply with the manufacturer's instructions and the SDS supplied with equipment cleaning compounds. NOTE: SDSs for cleaning compounds that are sold by Nordson are available at www.nordson.com or by calling your Nordson representative. Confirm the correct operation of all safety devices before placing the equipment back into operation.
  • Page 12: Equipment Safety Information

    NOTE: Government regulations and industry standards dictate specific requirements for the isolation of hazardous energy sources. Refer to the appropriate regulation or standard. Issued 9−17 E 2021 Nordson Corporation Part 1126187_05...
  • Page 13 Programmable Logic Controller [PLC], etc.). 2. Disconnect the input signal wiring to the applicator. 3. Reduce the air pressure to the system, then relieve the residual air pressure between the air control kit and the applicator. Issued 9-17 E 2021 Nordson Corporation Part 1126187_05...
  • Page 14: General Safety Warnings And Cautions

    General Safety Warnings and Cautions The following table contains the general safety warnings and cautions that apply to Nordson hot melt and cold adhesive equipment. Review the table and carefully read all of the warnings or cautions that apply to the type of equipment described in this manual.
  • Page 15 WARNING! Risk of fire or explosion! Nordson adhesive equipment is not rated for use in explosive environments and has not been certified for the ATEX directive or as nonincendive. In addition, this equipment should not be used with solvent‐based adhesives that can create an...
  • Page 16 CAUTION! Nordson hot melt equipment is factory tested with Nordson Type R fluid that contains polyester adipate plasticizer. Certain hot melt materials can react with Type R fluid and form a solid gum that can clog the equipment.
  • Page 17: Other Safety Precautions

    3. Do NOT attempt to remove the solidified hot melt from your skin. 4. In case of severe burns, treat for shock. 5. Seek expert medical attention immediately. Give the SDS for the hot melt to the medical personnel providing treatment. Issued 9-17 E 2021 Nordson Corporation Part 1126187_05...
  • Page 18: Safety Labels And Tags

    Figure 1‐1 Safety labels and tags Table 1‐2Safety Labels and Tags Item Part Description - - - - - - Sign, power - - - - - - Sign, hot Issued 9−17 E 2021 Nordson Corporation Part 1126187_05...
  • Page 19: Description

    Description Section 2 Description Overview This manual describes the installation and use of the Nordson Vulcan Jet™ dispensing system. When necessary, the reader is referred to the documentation supplied with other Nordson products or products supplied by third parties. The Vulcan Jet dispensing system liquifies solid‐form polyurethane reactive (PUR) hot melt adhesive contained in 30‐cc cartridges and maintains the...
  • Page 20: Intended Use

    With compatible equipment manufactured by Nordson Corporation In non‐explosive environments The Vulcan Jet dispensing system is virtually complete, but is intended to be incorporated into machinery or assemblies by an integrator. The equipment must not be placed into use in a member state of the European Union until the parent machinery or assemblies have been declared by the integrator to be in conformity with the applicable directives of the European Commission.
  • Page 21: Unit Identification

    See Figure 2‐2. You will need the model and part number of the applicator when requesting service or ordering spare parts and optional equipment. The applicator model and part number are indicated on the equipment identification plate. Figure 2‐2 Applicator equipment identification plate Part 1126187_05 E 2021 Nordson Corporation...
  • Page 22: Key Components

    1. Applicator 4. Applicator controller output 7. Moving plate 2. Air cap 5. Applicator piezo actuator output 8. Robot 3. Air supply inlet 6. Robot controls 9. Robot power switch (on back of unit) E 2021 Nordson Corporation Part 1126187_05...
  • Page 23 Description Figure 2‐4 Pneumatic Kit Components 1. Air supply input 3. Flow solenoid 5. Air output port 2. Air pressure controller 4. Flow sensor 6. Air filter Part 1126187_05 E 2021 Nordson Corporation...
  • Page 24 Description Key Components (contd) Figure 2‐5 Vulcan Jet controller (front view) 1. Touch screen 2. Supports (two per side) E 2021 Nordson Corporation Part 1126187_05...
  • Page 25 Description Figure 2‐6 Key components of the Vulcan Jet controller (rear view) 1. Power switch 9. Applicator piezo driver output 17. Heater 24 VDC power indicator 2. Heater status indicator 10. PUR cartridge level indicator 18. Cartridge heating indicator 3. Manifold/Nozzle heating indicator 11.
  • Page 26 Description This page intentionally left blank. E 2021 Nordson Corporation Part 1126187_05...
  • Page 27: Installation

    The instructions provided in this section are intended to be used by personnel who have experience in the following areas: Hot melt application processes Industrial power and control wiring Industrial mechanical installation practices Basic process control and instrumentation Part 1126187_05 E 2021 Nordson Corporation...
  • Page 28: Contents Of The Ship-With Kit

    1125557 Controller Assembly 1125686 Applicator Assembly 1125078 Pneumatic Kit 1125179 Applicator Piezo Cable 1125180 Applicator PCB Cable 1125181 Pressure Regulator Cable 1125182 Flow Meter Cable 1125184 Solenoid Cable 7361296 Touch Controller Power Supply Kit E 2021 Nordson Corporation Part 1126187_05...
  • Page 29: Vulcan Jet Controller Hardware Installation Overview

    Installation Vulcan Jet Controller Hardware Installation Overview Overview Installing the Vulcan Jet Applicator/Controller is a five-step procedure: Step Description Mounting the Bracket and Applicator Setting up the Air Kit and Applicator Connecting the Controller and Air Cables Commissioning the Controller...
  • Page 30: Step 1: Mounting The Bracket And Applicator

    Installation Step 1: Mounting the Bracket and Applicator 1. Unpack the Vulcan Jet controller and all components. Leave all cables in their bags. 2. Mounting the bracket and securing the Vulcan Jet Applicator assembly: For supported robots: Continue to the next step on page 3-5.
  • Page 31 Assembly 2. Gantry 3. Using a 4 mm hex driver, mount the Vulcan Jet bracket (1) to the supported robot gantry (2). Make sure the catch groove is facing up. 4. Slide the applicator assembly (3) between the mounting grooves of the mounting plate (1), then secure it to mounting bracket (1) with a 3 mm hex driver.
  • Page 32: Step 2: Setting Up The Air Kit And Applicator

    The air supply must be clean, dry, regulated, and unlubricated compressed air. Make sure the air connections are secure and leak free. The thread on the Air Kit connector is R ¼. You may need an adaptor for your application. E 2021 Nordson Corporation Part 1126187_05...
  • Page 33: Step 3: Connecting The Controller And Air Cables

    2. When done, proceed to Step 4, Commissioning the Controller. 1125184 1125181 1125182 PNEUMATIC KIT FRONT CONTROLLER BACK ROBOT BACK 1125179 DB-25, Straight-pin, Male-to-Male I/O Cable 1125180 (Customer supplied) APPLICATOR RIGHT Figure 3‐3 Cable connections Part 1126187_05 E 2021 Nordson Corporation...
  • Page 34 An Alert has been detected in the robot. Controller should continue to operate. Pressurize Cartridge The controller should apply air pressure to the cartridge when active Emergency Stop The controller should stop applying adhesive and turn Off heaters when active. E 2021 Nordson Corporation Part 1126187_05...
  • Page 35: Step 4: Commissioning The Controller

    NOTES: Make sure the Vulcan Jet Controller main power supply is energized or plugged in. Facing the Vulcan Jet controller, the power switch is located on the upper- right back corner. 1. Power up the Vulcan Jet controller. The Commissioning Wizard starts. You will be asked to provide the...
  • Page 36: Step 5: Testing/Purging The System For The First Time

    2. Green ribbon band and green check mark The green ribbon and green check mark indicates that heaters are on, and the cartridge and nozzle are at set point temperature. The controller is in a Ready/OK state - ready for production. E 2021 Nordson Corporation Part 1126187_05...
  • Page 37 Home screen to toggle Purge On. CAUTION! The Vulcan Jet will make a loud sound while purging/jetting. The system should start jetting. Wait until you see your cleaning or production adhesive come out of the applicator, then toggle Purge Off.
  • Page 38 3-12 Installation This page intentionally left blank. E 2021 Nordson Corporation Part 1126187_05...
  • Page 39 Overview The controller is shipped from the factory with most software settings preconfigured and ready to use. However, there are some settings that you must configure and fine­tune to best fit your manufacturing process. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 40: About The Touch Screen And User Interface

    You can make changes to these default settings once you are done with this wizard. The last procedure in commissioning is adjusting the stroke. This must be done when the controller is in a Ready/OK state. You must Purge the system before using it. E 2021 Nordson Corporation Part 1126187_05...
  • Page 41: Navigating And Monitoring The Controller

    About the Touch Screen and User Interface Navigating and Monitoring the Controller The Vulcan Jet Controller consists of the following primary screens: The Home screen Master Controls screen System Screen Settings Screen About the Home Screen The Home screen is the default screen.
  • Page 42 View controller status View state of the Master Heater control, and whether or not password protection is enabled View and manage recipes Navigation Access the Master Controls screen Access the Settings screen Access the System screen E 2021 Nordson Corporation Part 1126187_05...
  • Page 43: Monitoring The Overall Status Of The Controller

    The controller is not in Standby mode (manual, auto, or scheduled). Controller is not in Cartridge Ready Delay mode. Orange Heating Both the Cartridge and Nozzle zones are in the process of heating to their set point temperatures. Continued... Part 1126187_05 E 2021 Nordson Corporation...
  • Page 44 Either the system and/or a zone has caused a Fault condition. The system automatically switches Off the Master Heater controls. Dark Blue Standby The controller was placed into Standby mode using either Manual, Auto, or Scheduled method. Continued... E 2021 Nordson Corporation Part 1126187_05...
  • Page 45 The controller continues to operate, but servicing may be required. Recipe Touch to access the Recipe Management screen, where you can Current Status On or Off load/unload a recipe as well as create or delete a recipe. Continued... Part 1126187_05 E 2021 Nordson Corporation...
  • Page 46 Security Indicates that security is being enforced, and a password code was successfully entered. Master Heater Control Green The Master Heater Control is On. Master Heater Control Gray The Master Heater Control is Off. E 2021 Nordson Corporation Part 1126187_05...
  • Page 47: Monitoring The Pressure Zone

    Life Timer Count Count 1,000,000,000 4:40 About Pressure Statuses Refer to Table 4‐1 for a detailed list and explanation of each pressure status. Pressure 20 PSI Real-time system pressure Figure 4‐3 Pressure button details Part 1126187_05 E 2021 Nordson Corporation...
  • Page 48 15 PSI is switched Off. Production stops. NOTE: You can modify the pressure set point regardless of system state or status. The state of a zone is independent of the overall status of the applicator/controller. E 2021 Nordson Corporation Part 1126187_05...
  • Page 49: Monitoring The Heated Zones

    Figure 4‐5 details what an enabled zone displays. Refer to Table 4‐2 for a detailed list and explanation of each zone state and status. Name of zone Cartridge 145_ C Real-time temperature indicator Figure 4‐5 Zone button Details Part 1126187_05 E 2021 Nordson Corporation...
  • Page 50 NOTE: In a fault condition, the Master Heater control is switched Off. Production stops. Fault Dark Blue Standby The system was placed into Standby. Zone 1 NOTE: You can modify heated zones regardless of system state or status. E 2021 Nordson Corporation Part 1126187_05...
  • Page 51: Monitoring The Counters

    Dot Count Reset The number of dots the controller created. A dot is counted when the actuator completes one complete waveform cycle. NOTE: This counter does not interact with any other counter or log. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 52: About The Home Screen Navigation

    Modify and manage the Seal Pack and Needle Seat Service Reminders. View system information. Access the Administration screen to modify and manage advanced system settings, such as: System Reset, Diagnostics Log, Reset System Passwords, Recipes, and Network Configuration. Enable/disable Lockout Communications option. E 2021 Nordson Corporation Part 1126187_05...
  • Page 53: Monitoring Input/Output Statuses

    Robot Ready Robot Running Applicator Control Standby Control Robot Fault Applicator Home Pressurize Cartridge Fault Reset Emergency Stop 1. From the Home screen, do one of the following: Touch Master Touch , then touch button. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 54 NOTE: For signal sources that actively drive the signal to both 24V and 0V, select PNP for the input type to maintain positive logic (24V input is the active state). An NPN setting will provide negative logic (0V is the active state). E 2021 Nordson Corporation Part 1126187_05...
  • Page 55 I/O Connector When active, causes the applicator to fire a waveform. Applicator Control from NOTE: The Vulcan Jet Controller must be in a Ready/OK parent machine (robot) state. When active, (energized state) pulse resets all alarms and Fault Reset warnings.
  • Page 56: Output Statuses

    Standby Active Running Faults Low Cartridge Level Product Complete Empty Cartridge Emergency Stop 1. From the Home screen, do one of the following: Touch Master Touch , then touch button. 2. Touch View Output Status. E 2021 Nordson Corporation Part 1126187_05...
  • Page 57 Running Active when a product is jetting. An analog output that controls the waveform applied to Jetting Applicator Control the piezo element. A second solenoid output that removes pressure from the Dump pressure cartridge. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 58 4-20 About the Touch Screen and User Interface This page intentionally left blank. E 2021 Nordson Corporation Part 1126187_05...
  • Page 59: Basic Operation And Controller Configuration

    Basic Operation and Controller Configuration Section 5 Basic Operation and Controller Configuration WARNING! Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 60: Overview

    When the applicator is cleaned, you must remove cured PUR adhesive from all adhesive passages (see Figure 5‐1), not just the adhesive passages inside the module. Refer to Cleaning the Applicator on page 7-8. Figure 5‐1 Diagram of Adhesive Passages E 2021 Nordson Corporation Part 1126187_05...
  • Page 61: Daily Start-Up Procedure

    Tip: Look in the upper-right hand corner of the touch screen. You should see the following Ready/OK status icon 6. Place the product on the moving plate and press the START button on the robot to run products. Robot START button Part 1126187_05 E 2021 Nordson Corporation...
  • Page 62: Overnight And Long-Term Shutdown Procedures

    4. Purge until a clean flow of flush material is achieved. 5. Leave the flush cartridge in the applicator. 6. Turn off the air supply. 7. Turn off the controller. 8. Turn off the robot. E 2021 Nordson Corporation Part 1126187_05...
  • Page 63: Using The Master Heater And Standby Controls

    Standby Control Manually switch the controller in or out of Standby mode. 3. Touch NOTE: Refer to the previous chapter for more information about what you can do from the Settings and System screens. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 64: Purging

    It is recommended that you purge the system to clear debris within the delivery system after changing a cartridge. You can purge the system from the Vulcan Jet controller only if it is in a Ready/OK state and if the applicator is in its Home position.
  • Page 65 Do you want to reset the Adhesive Life Timer? Message. If you do not reset the timer, you may receive false Adhesive Life Timer alert messages. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 66: Creating An Input Waveform

    You cannot access the Input Waveform screen if the system is currently in production. The Vulcan Jet controller must be in a Ready/OK state, and the applicator in its Home position. The following sections describe and detail each step in this process.
  • Page 67: Modifying System Pressure Set Point

    2. Enter the pressure set point you want to use. When done, touch NOTE: When purging, the system uses this pressure set point along with the current Input Wave Form settings. Use the Pressure Compensation option to help the controller maintain system pressure. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 68: Creating A Waveform

    Touch , then touch button. 2. Touch Settings | Applicator then touch Input Waveform. Settings Applicator Input Waveform Standard Optional 3. From the Input Waveform screen, select one of the following: Standard (default) Optional. E 2021 Nordson Corporation Part 1126187_05...
  • Page 69 3. Touch when done. NOTE: The robot must be in its Home position and the controller must be in a Ready/OK status. You can save a waveform or pattern to a recipe for later use. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 70 3. Touch when done. NOTE: The robot must be in its Home position and the controller must be in a Ready/OK status. You can save a waveform or pattern to a recipe for later use. E 2021 Nordson Corporation Part 1126187_05...
  • Page 71: Managing Recipes

    Managing Recipes Use recipes to save production settings such as temperature, pressure, and waveform, and other controller settings including standby events and security settings to a file that you can use, modify, and share with other Vulcan Jet controllers. NOTE: You can share recipes with other Vulcan Jet controllers.
  • Page 72 Only one recipe can be exported at a time. The first time that you export a recipe to a USB drive, the system creates a /Recipes folder on the USB drive. The system exports all recipes to this folder. E 2021 Nordson Corporation Part 1126187_05...
  • Page 73 Unloads the currently loaded recipe make use of any Select this option when troubleshooting or performing recipe maintenance on the controller. Do not use a Recipe NOTE: The melter retains the settings of the previously loaded recipe. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 74: What's Being Saved In A Recipe

    Auto Heaters Off Time value Auto Standby Time value Cartridge Information Waveform information Ready delay (enabled or disabled and value Waveform (t1, t2 and t3) values Level threshold values Applicator Mode Adhesive lifetime counter E 2021 Nordson Corporation Part 1126187_05...
  • Page 75: Advanced Controller Configuration

    The controller is shipped from the factory with most temperature, pressure and jetting system settings preconfigured and ready to use. However, there are some settings that you must configure and fine­tune to best fit your manufacturing process. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 76 Defining system security settings Protection Administrative Accessing options and settings Options and Upgrading/downgrading software and firmware Settings Viewing the event log Resetting to system defaults Resetting password codes Locking out melter communication Configuring Network Settings E 2021 Nordson Corporation Part 1126187_05...
  • Page 77: Advanced Temperature Settings

    1. From the Home screen, do one of the following: Touch Master Touch , then touch button. 2. Touch System, | Temperature, then modify the Over/Under temperature threshold that you want to use. 3. Touch Part 1126187_05 E 2021 Nordson Corporation...
  • Page 78: Configuring Cartridge Ready Delay

    Use the Cartridge Ready Delay option to define the amount of time you want to elapse after the zones have reached their set point temperatures before the Vulcan Jet Controller status is Ready/OK. This delay allows for the adhesive to melt, ready for production.
  • Page 79: Configuring Standby Mode Settings

    1. From the Home screen, touch 2. Decide if you want to enter into or exit out of the Standby feature. Button Color Description Green Enter into Standby mode White Exit out of Standby mode Part 1126187_05 E 2021 Nordson Corporation...
  • Page 80: Configuring Manual Standby

    Touch Master Touch , then touch button. 2. Touch Standby. 3. Touch Manual Standby. If you decide to Enable this feature, then enter the Auto Exit Standby Time you want to use. 4. Touch E 2021 Nordson Corporation Part 1126187_05...
  • Page 81: Defining Standby Temperature Offset

    Touch Master Touch , then touch button. 2. Touch Standby. 3. Touch Standby Temperature Offset and enter the temperature offset that you want to use while the controller is in Standby mode. 4. Touch Part 1126187_05 E 2021 Nordson Corporation...
  • Page 82: Advanced Applicator Settings

    Advanced Applicator Settings Performing a Stroke Adjustment As part of the initial commissioning of the Vulcan Jet controller, a stroke adjustment is performed. Typically, you perform a stroke adjustment again only when you replace the Needle Seat or Seal Pack components.
  • Page 83: Changing Applicator Modes

    Applies adhesive as long as the Applicator Control input is active. Burst When the Applicator Control input is active, the controller applies a user-defined number of dots. NOTE: Typically used when you want to get a weighted adhesive sample. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 84: Advanced Pressure Settings

    1. From the Home screen, do one of the following: Touch Touch , then touch button. 2. Touch Pressure. 3. Touch Pressure Compensation. If you decide to Enable this feature, enter the pressure compensation value you want want to use. 4. Touch E 2021 Nordson Corporation Part 1126187_05...
  • Page 85: Advanced Cartridge Settings

    Touch Touch , then touch button. 2. Touch Cartridge. 3. Touch Cartridge Level Thresholds. Enter the low level and Empty adhesive amount (mL) for which you want to receive an Alert message. 4. Touch Part 1126187_05 E 2021 Nordson Corporation...
  • Page 86: Modifying Adhesive Lifetime Counter

    , then touch button. 2. Touch Cartridge. 3. Touch Adhesive Lifetime Counter. Enter the amount of time (minutes) before you want a notification that it is recommended that you replace the adhesive cartridge. 4. Touch E 2021 Nordson Corporation Part 1126187_05...
  • Page 87: System Settings

    Advanced Controller Configuration System Settings The following sections detail: Modifying System Formats and Units Modifying System Data and Time Managing Applicator Service Reminders Defining Language Preference Defining Display Settings Configuring System Security Viewing System Information Part 1126187_05 E 2021 Nordson Corporation...
  • Page 88: Modifying System Formats And Units

    1. From the Home screen, do one of the following: Touch Master Touch , then touch button. 2. Touch System, then touch Formats/Units. 3. Touch the selection you want to use for each format/unit. E 2021 Nordson Corporation Part 1126187_05...
  • Page 89: Modifying System Date And Time

    2. Touch System, then touch Date/Time. 3. Enter the current date and time. Touch to move forward between date and time fields. 4. Touch NOTE: You must manually adjust the date and time for seasonal/regional time changes. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 90: Managing Applicator Service Reminders

    3. Touch Cartridge Level Thresholds. Enter the low level adhesive amount (mL) at which you want to receive an Alert or Fault message. 4. Touch NOTE: Numbers appearing in yellow correspond to the item that should be replaced. E 2021 Nordson Corporation Part 1126187_05...
  • Page 91 This is the item that should have already been replaced. 3. Touch . The following happens: The numbers for the item are reset and now appear blue. The Service Reminder icon is removed from the Top Status Bar Part 1126187_05 E 2021 Nordson Corporation...
  • Page 92: Defining Language Preference

    English 1. From the Home screen, do one of the following: Touch Master Touch , then touch button. 2. Touch System., then touch Language. 3. Touch the language you want to use. 4. Touch E 2021 Nordson Corporation Part 1126187_05...
  • Page 93: Defining Display Settings

    Service Reminders Administration Screen Saver Delay Language System Information English Wipe Display 1. From the Home screen, do one of the following: Touch Master Touch , then touch button. 2. Touch System, then touch Display. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 94 Touch anywhere on the screen to access the Home screen. Wipe Display Locks the screen for 30 seconds, allowing you to clear dust from the touch screen without touching a button and accidentally changing a setting 4. Touch E 2021 Nordson Corporation Part 1126187_05...
  • Page 95: Configuring System Security

    Change System Modify the default numeric password code. Password (code) NOTE: The password code can be from one to five digits, however, the first digit cannot start with the number 0 (zero). Part 1126187_05 E 2021 Nordson Corporation...
  • Page 96 Temperature Limits Manual Standby Standby Temperature Offset Stroke Adjustment Input Waveform System Security Cartridge Ready Delay Cartridge Level Thresholds Input Status (Change between PNP and NPN) Service Reminders (Reset) Administration (System Reset) Network Configuration E 2021 Nordson Corporation Part 1126187_05...
  • Page 97: Viewing System Information

    English MDIO Board: 8.7 1. From the Home screen, do one of the following: Touch Master Touch , then touch button. 2. Touch System, then touch System Information. Review the information. When done, Touch Part 1126187_05 E 2021 Nordson Corporation...
  • Page 98: Administrative Options And Settings

    Viewing the Event Log - Save Diagnostics Resetting to System Defaults ‐ Managing recipes Resetting Password Codes Locking Out melter communication Connecting to a Network. Viewing software/firmware version information Viewing heaters On hours Changing RTD types E 2021 Nordson Corporation Part 1126187_05...
  • Page 99: Upgrading/Downgrading Software And Firmware

    To perform an upgrade, go to https://emanuals.nordson.com/adhesives/software/, navigate to Unity & Vulcan Jet, and download the .dat file to the root of the USB drive. To perform a downgrade, access the USB drive from a PC, open the /Old folder and move the file to the USB Root directory.
  • Page 100: Viewing The Event Log - Save Diagnostics

    Additionally, a Diagnosticsfile.xml file is also written to the USB drive. This file contains detailed melter information. The information contained in both files can help Nordson technical support troubleshoot your issue. NOTE: The system writes the entire event log to the USB drive, regardless of what level of detail you selected.
  • Page 101 When done, the Attention message appears, stating: “Diagnostics file has been saved to USB.” The default names are: EventLog.xml Diagnosticsfile.xml Part 1126187_05 E 2021 Nordson Corporation...
  • Page 102: Resetting To System Defaults

    3. Touch System Reset. Decide if you want to reset the Service Reminders as well as the Lifetime Cycle Counter. 4. Touch 5. A pop-up message appears. Touch Yes to revert all user-definable settings back to factory defaults. E 2021 Nordson Corporation Part 1126187_05...
  • Page 103: Resetting Password Codes

    2. Touch System, then touch Administration. 3. Do one the following to continue: Touch Reset System Password. A pop-up message appears. 4. Touch Yes to revert the password code to 1000, the default value. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 104: Locking Out Communications

    1. From the Home screen, do one of the following: Touch Master Touch , then touch button. 2. Touch System, then touch Administration. 3. Touch the Lockout Communication button to toggle it between Enable and Disable. 4. Touch E 2021 Nordson Corporation Part 1126187_05...
  • Page 105: Connecting To A Network

    . A confirmation message box appears. The controller automatically reboots itself and returns to the Home screen. NOTE: If you do not know these IP addresses, ask your network administrator. Network IP addresses are not saved in a recipe. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 106: Default User Settings And Ranges

    Minimum: 0 minutes Maximum: 1440 minutes Auto Exit Standby Time Disabled Enabled Disabled Auto Exit Standby Time 45 minutes Minimum: 1 minute Maximum: 180 minutes Standby Temp 50_C (100_F) Minimum: 5_C (10_F) Maximum: 60_C (110_F) E 2021 Nordson Corporation Part 1126187_05...
  • Page 107 Dwell Time (t1) 0.05 ms Minimum: 0.05 ms Maximum: 0.2 ms Closing Time (t2) 0.3 ms Minimum: 0.2 ms Maximum: 0.4 ms One Complete Cycle (t3) 3 ms Minimum: 3 ms Maximum: 10 ms Continued... Part 1126187_05 E 2021 Nordson Corporation...
  • Page 108 Maximum: 100 Cycles/million Service Interval: Needle Seat 100 Cycles/million Minimum: 20 Cycles/million Maximum: 100 Cycles/million Password Protection No Password Protection High Medium No Password Protection Password Timeout 1 minute Minimum: 1 minute Maximum: 60 minutes Continued... E 2021 Nordson Corporation Part 1126187_05...
  • Page 109 Maximum: 100% Display Screen Saver Delay Enabled Minimum: 1 minute 5 minutes Maximum: 120 minutes Lockout Communications Network Settings Setting Default Range/Option Public IP Address 192.168.003.001 Public IP Subnet 255.255.255.000 Public Default Gateway 192.168.003.250 Part 1126187_05 E 2021 Nordson Corporation...
  • Page 110 6-36 Advanced Controller Configuration This page intentionally left blank. E 2021 Nordson Corporation Part 1126187_05...
  • Page 111: Communication Data List

    Communication Data List NOTE: The following Data Designations are supported for the Vulcan Jet controller. Control Data Data Modbus Address Read Data Description Data Functional Description Size 40101 - 40102 16 bit Zone 1 Set Point Unsigned Short: Zone 1 Temperature Set Point in Degrees Fahrenheit, 70 - 374...
  • Page 112: Status Data

    Status Data Data Modbus Address Data Description Data Functional Description Read Size 40001 - 40002 16 bit Zone 1 Current Unsigned Short: Zone 1 Temperature Set Point in Degrees Fahrenheit (Nozzle) Temperature 40003 - 40004 16 bit Zone 2 Current Unsigned Short: Zone 2 Temperature Set Point in Degrees Fahrenheit (Cartridge) Temperature 40005 - 40006...
  • Page 113 Status Data(contd) Data Modbus Address Data Description Data Functional Description Read Size 40023 - 40024 16 bit Piezo Driver Status Unsigned Short: 16 bits Bit 0 : Piezo Not Present Bit 1 : Piezo Low Voltage Power Supply Fault Bit 2 : Piezo High Voltage Power Supply Over Voltage Bit 3 : Piezo High Voltage Power Supply Overload Bit 4 : Piezo Over Temperature Bit 5 : Piezo Valve Not Present...
  • Page 114: Alert Data

    Alert Data Data Modbus Address Data Description Data Functional Description Read Size 40013 8 bit Zone 1 Alerts Unsigned Short: 8 bits Bit 0 : Zone 1 Low Temperature Alert Bit 1 : Zone 1 High Temperature Alert Bit 2 : Zone 1 RTD Short Alert Bit 3 : Zone 1 RTD Open Alert Bit 5 : Zone 1 Write Temperature Set Point Invalid Alert 40014...
  • Page 115: Fault Data

    Fault Data Data Modbus Address Data Description Data Functional Description Read Size 40017 8 bit Zone 1 Faults Unsigned Short: 8 bits Bit 0 : Zone 1 Low Temperature Fault Bit 1 : Zone 1 High Temperature Fault Bit 2 : Zone 1 RTD Short Fault Bit 3 : Zone 1 RTD Open Fault Bit 5 : Zone 1 Run Away Temperature Fault 40018...
  • Page 116: Recipe Data

    Recipe Data 40119 - 40120 16 bit Recipe Loading Unsigned Short: 8 bits. Note: Only set 1 bit at a time. Recipe 1 Loading Bit 0 : Load RECIPE1.xml Recipe 2 Loading Bit 1 : Load RECIPE2.xml Recipe 3 Loading Bit 2 : Load RECIPE3.xml Recipe 4 Loading Bit 3 : Load RECIPE4.xml...
  • Page 117: Maintenance

    Maintenance Section 7 Maintenance WARNING! Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 118: Overview

    Use only original Nordson spare parts. Clean the exterior Daily Remove adhesive residue only with a cleaning agent recommended by the adhesive supplier.
  • Page 119: Flushing The System

    Refer to the Safety Data Sheet (SDS) for both the adhesive and the flushing material. NOTE: Before flushing the system, the Vulcan Jet Controller must be in a Ready/OK state. 1. See Figure 7-1. Load a flush cartridge in the applicator as follows: Remove the air cap (1) and remove and discard the adhesive cartridge (2).
  • Page 120: General Disassembly

    Pivot the bracket to access the circuit board. Disconnect the following from the applicator circuit board: X4, Piezo thermocouple wires (1) (using a 0.025-inch flat-blade screwdriver) X5, cartridge heater connector (2) X6, heater block connector (3) X7, Piezo driver connector (4) Part 1126187_05 E 2021 Nordson Corporation...
  • Page 121 Maintenance Figure 7-2 General Disassembly Part 1126187_05 E 2021 Nordson Corporation...
  • Page 122 6. Use a 3 mm hex wrench to remove the two screws (1) that attach the mounting bracket to the top of the applicator. Then, remove the other two screws (2) that pass through the mounting bracket into the back of the applicator. Figure 7-4 Applicator Removal Part 1126187_05 E 2021 Nordson Corporation...
  • Page 123 (3), and set these components aside. NOTE: Be careful to not damage cartridge heater wiring when removing cartridge. Figure 7-5 Actuator and Cartridge Heater Removal 8. Go to Removing the Nozzle Plate Assembly given next. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 124: Removing The Nozzle Plate Assembly

    4. Nozzle plate 7. Heater block assembly 2. Adjustment screws (2) 5. Screw 8. Applicator needle 3. O-ring 6. Screw 9. Plastic needle housing 5. Go to Removing the Seal Pack given next to continue. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 125: Removing The Seal Pack

    Figure 7-7 Replacing the seal pack 1. Applicator 3. Adjustment screws (2) 5. Seal pack 2. Plastic needle housing 4. Applicator needle 3. Go to Cleaning the Applicator given next to continue. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 126: Cleaning The Applicator

    4. Clean the nozzle plate and heater block using one of the Nordson-recommended methods shown in Table 7-2. Use only cleaning agents recommended by the adhesive supplier. Table 7-2 Nozzle Plate and Heater Block Cleaning Methods...
  • Page 127 Nordson Corporation recommends testing this procedure on discarded heater blocks and nozzle plates prior to using them on good components.
  • Page 128: Removing The Applicator Needle

    (1). The spring (2) will come out of the applicator when the needle is removed. NOTE: The P/N 1125092 needle removal tool is included with the P/N 1126067 needle replacement kit. Figure 7-8 Applicator Needle Removal Part 1126187_05 E 2021 Nordson Corporation...
  • Page 129: Installing The Applicator Needle

    Installing the Applicator Needle NOTE: Before putting the needle and other items back together, follow the alignment instructions given in Vulcan Jet Alignment Tool (P/N 1130498). 1. Obtain a new applicator needle (5). 2. Hold the top and bottom of the frame plates (1) and insert the spring (4) and needle (5) into the plastic needle housing (3).
  • Page 130: Installing The Seal Pack

    3. Adjustment screws (2) 5. Seal pack 2. Plastic needle housing 4. Applicator needle 6. Gently push the seal pack into the heater block. 7. When done, go to Installing the Nozzle Plate Assembly given next. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 131: Installing The Nozzle Plate Assembly

    4. Go to General Reassembly given later in this section. Figure 7-11 Nozzle Plate Installation 1. Applicator 3. Applicator needle 6. Screws (2) 2. Adjustment screws (2) 4. O-ring 7. Heater block 5. Nozzle plate assembly Part 1126187_05 E 2021 Nordson Corporation...
  • Page 132: Removing The Piezo Actuator

    4. Use a 3 mm hex driver and fingers to remove the two stroke adjustment screws (1) from the frame plate. Figure 7-12 Frame Plate Disassembly 5. Turn the applicator over as shown in Figure 7-13 and place back on table. Figure 7-13 Frame Plate Disassembly Part 1126187_05 E 2021 Nordson Corporation...
  • Page 133 (2) that hold the air flush heat exchanger (3) to the slide block (5). Figure 7-15 Piezo Actuator Disassembly 11. Use a 2.5 mm hex driver to remove the two screws (4) that hold the slide block (5) to the piezo actuator (6). Part 1126187_05 E 2021 Nordson Corporation...
  • Page 134: Installing The Piezo Actuator

    Figure 7-17 Piezo Actuator Assembly 5. Slide the aluminum block (5), onto the air fitting on the air flush heat exchanger (4). 6. Place the applicator on a table as shown in Figure 7-18. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 135 Refer to Installing the Applicator Needle given earlier in this section. Refer to Installing the Seal Pack given earlier in this section. Refer to Installing the Nozzle Plate Assembly given earlier in this section. Refer to General Reassembly given next. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 136: General Reassembly

    Refer to Installing the Nozzle Plate Assembly given earlier in this section. 2. Place the cartridge heater (3) onto the Luer lock (4), then place the actuator (1) into the frame (2). Figure 7-20 Actuator and Cartridge Heater Installation Part 1126187_05 E 2021 Nordson Corporation...
  • Page 137 X4, piezo thermocouple (1), using a 0.025-inch flat-blade screwdriver X5, cartridge heater (2) X6, heater block (3) X7, piezo driver (4) Figure 7-22 Circuit Board Access 5. Tighten the screw (6) that holds the hinged circuit board mount bracket (5) in place. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 138 7. Attach the following to the applicator: a. the air line (1) to the air cap (2) b. both cables (5) from the controller 8. Slide the applicator into the mounting block (7) and tighten the mounting block screw (6). Part 1126187_05 E 2021 Nordson Corporation...
  • Page 139 Install the air cap (2). 10. Energize the controller, then switch it On. 11. Perform stroke adjustment. Refer to Advanced Applicator Settings given in Advanced Controller Configuration, Section 6. 12. Restore the system to normal operation. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 140: Adjusting The Stroke Settings

    Counter Life Timer Count Count 1,000,000,000 4:40 2. Touch the Applicator button on the Settings screen. Settings Temperature Limits View Input Status OT 25°C | UT 50°F Cartridge View Output Status Applicator Pressure Standby Part 1126187_05 E 2021 Nordson Corporation...
  • Page 141 3. Touch the Stroke Adjustment button on the Applicator screen. Applicator Settings Stroke Adjustment Temperature Limits View Input Status Input Waveform Cartridge View Output Status Applicator Applicator Mode 4. Review the two images in the following screen and touch Stroke Adjustment Part 1126187_05 E 2021 Nordson Corporation...
  • Page 142 Replace cover and 3 screws Tighten the 2 screws on the applicator 7. Tighten the screws for stroke adjustment. Torque the screws to 11-12 in-lb. 8. Install the applicator cover by reattaching the three screws. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 143: Troubleshooting

    This section contains troubleshooting procedures. These procedures cover only the most common problems that you may encounter. If you cannot solve the problem with the information given here, contact your local Nordson representative for help. Overview Troubleshooting begins when the flow of adhesive from the applicator stops or diminishes unexpectedly or when a control system alerts you of a problem through an alarm or visual display.
  • Page 144: Heater/Rtd Alarm Troubleshooting

    Refer to the figure below and the following table to troubleshoot the alarms generated by the heater/RTD. Figure 8‐24 System Board Locations 1. Piezo driver 3. Power distribution board 2. I/O board 4. Communications board E 2021 Nordson Corporation Part 1126187_05...
  • Page 145 Assembly (PCA) board exceeded the Cartridge Heater allowable limit. Open Fault condition - if the issue is not resolved within 2 minutes of the alert message, the heater is switched off. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 146: Pressure/Adhesive Alarm Troubleshooting

    The result of creating product Replace cartridge. cartridge soon. The available adhesive in the cartridge is equal to Empty Cartridge or less than the Fault Empty Level Fault threshold value. Production stops. E 2021 Nordson Corporation Part 1126187_05...
  • Page 147: Input/Output Alarm Troubleshooting

    Power Supply exceeded the Overload Alarm Defective I/O PCA Check external devices allowable limit. attached to the 24V output supply for short circuits. Replace I/O PCA. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 148 Output state does Diagnostic Failure Defective I/O PCA cables as needed. Alarm not match programmed state. Replace I/O PCA. Running output Running Output diagnostic failure. Diagnostic Failure Output state does not match Alarm programmed state. E 2021 Nordson Corporation Part 1126187_05...
  • Page 149 Decrease actuator cycle rate. The temperature of Decrease ambient High ambient temperature Piezo Temperature the piezo (measured temperature. Too High Alarm with thermocouple) Cycling applicator too fast is too high. Increase pause time between products. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 150: Storage Alarm Troubleshooting

    Delete the recipe and re-create it Alert opened. Changes made to the recipe are not Recipe Changes Not Always save recipe changes that saved due to power Saved Alert you wish to save. loss or remote recipe change. E 2021 Nordson Corporation Part 1126187_05...
  • Page 151: System Board Alarm Troubleshooting

    Table 8-5 System Board Alerts/Faults Effect on Screen Message Cause Corrective Action(s) Controller Controller Board Controller board Replace Controller Board. Failure Fault hardware failure RAM failure. RAM Test Fault Checked at power Reload file onto USB drive. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 152 Controller board Upgrade Alert canno t upgrade (nError code = The system remains on the current software version. The touchscreen Bad HMI Try to calibrate again. Touchscreen calibration fails. Otherwise, replace Calibration Fault touchscreen panel. E 2021 Nordson Corporation Part 1126187_05...
  • Page 153 Check that the cable cannot communicate connected properly. connections are seated with robot or parent External properly. Parent machine is Off. machine (external Communication Alert device). Make sure the parent machine is not On. Part 1126187_05 E 2021 Nordson Corporation...
  • Page 154: Temperature Alarm Troubleshooting

    The RTD for the component RTD on shorted or indicated has failed. open on <<# or Check the connections or Open/Shorted The component was Name>>. Controller replace the RTD. not working. disconnected from the controller. E 2021 Nordson Corporation Part 1126187_05...
  • Page 155: Piezo Driver Board Alarm Troubleshooting

    Piezo driver not conditions may exist. If fault persists, replace piezo Enabled Fault enabled driver board. 15 volt power supply Piezo ISO 15V Fault fault inside the piezo Defective piezo driver Replace piezo driver. driver board Part 1126187_05 E 2021 Nordson Corporation...
  • Page 156: Piezo Alarm Troubleshooting

    Applicator temperature setpoints Increase or decrease the temperature setpoint. too low or too high Refer to Set Up the Vulcan Jet Controller under Setup as needed. Failed heater or sensor Check the applicator heater or sensor. Continued... E 2021 Nordson Corporation...
  • Page 157 Applicator temperature setpoint Increase the temperature setpoint. Refer to Set (from part to part) too low Up the Vulcan Jet Controller under Setup as needed. Old PUR adhesive in system Clean or replace the nozzle plate, clean the adhesive passages (see Figure 8‐1), and/or replace the module.
  • Page 158 Up the Vulcan Jet Controller under Setup as needed. Module needle stroke too short Refer to the needle stroke adjustment steps in Set Up the Vulcan Jet Applicator under Setup as needed. Leaks at needle Adhesive seal failure Replace the seal pack.
  • Page 159: Parts

    A dash in this column indicates that the item is an assembly. The number in the Part column is the Nordson part number you can use to order the part. A series of dashes indicates that the part is not saleable. In this case, you must order either the assembly in which the part is used or a service kit that includes the part.
  • Page 160: Vulcan Jet Dispensing System Assemblies

    VULCAN JET CONTROLLER 7407852 ROBOT,UNITY 4XP,3AXIS,350 X 400 X 100MM NOTE A: Refer to Vulcan Jet Applicator Parts later in this section. B: Refer to Air Kit Parts later in this section. C: Refer to Controller Assemby Parts later in this section.
  • Page 161 Part Description Quantity Note S BRACKET, MOUNTING, VULCANJET 1125971 S S FRAME, PLATE, VULCANJET 1124940 S S FRAME, TOP, VULCAN JET 1124941 S S BLOCK, SLIDE, MOUNT, VULCANJET 1124942 S FRAME, BOTTOM, VULCANJET 1124939 S NOZZLE PLATE,ASSEMBLY,100UM,VJ 1128208 S HEATER, BLOCK ASM, VULCANJET...
  • Page 162 Parts Figure 9‐2 Vulcan Jet applicator parts E 2021 Nordson Corporation Part 1126187_05...
  • Page 163 Parts Figure 9‐3 Vulcan Jet applicator parts Part 1126187_05 E 2021 Nordson Corporation...
  • Page 164 Parts Vulcan Jet Applicator Parts See Figure 9‐4. Item Part Description Quantity Note — 1125078 KIT, PNEUMATIC, VULCAN JET — Figure 9‐4 Air kit parts E 2021 Nordson Corporation Part 1126187_05...
  • Page 165: Controller Assembly

    Parts Controller Assembly See Figure 9‐5. Item Part Description Quantity Note — 1125557  VULCAN JET CONTROLLER — S ENCLOSURE, NXGN PJ 1125075 S KIT,FRONT PANEL,ASSY,VULCANJET 1125595 S KIT,BOTTOM PANEL,ASSY,VULCANJET 1125592 S KIT,TOP PANEL,ASSY,VULCANJET 1125593 S KIT,REAR PANEL,ASSY,VULCANJET 1125594 S CABLE,USB,TYPE A COUPLER,FEMALE...
  • Page 166 Parts Figure 9‐5 Controller Assembly E 2021 Nordson Corporation Part 1126187_05...
  • Page 167: Cable Part Numbers

    The cables shown below are for use only in systems using 120‐ohm nickel sensors. Part Description Note 1034148 CABLEASSY,DSUB,25POS,M/M,25FT (not included) 1125179 CABLE,APPLICATOR PIEZO, VULCAN JET 1125180 CABLE ,APPLICATOR PCB, VULCAN JET 1125181 CABLE,PRESSURE REGULATOR, VULCAN JET 1125182 CABLE,FLOWMETER, VULCAN JET 1125183 CABLE,E-STOP, VULCAN JET 1125184 CABLE,SOLENOID, VULCAN JET Optional Accessories...
  • Page 168: Recommended Spare Parts And Supplies

    9-10 Parts Recommended Spare Parts and Supplies Equipment Part Item Note Vulcan Jet controller 1125557 VULCAN JET CONTROLLER 1122386 FUSE,MINI-BLADE,7.5AMPS,32VDC 1041036 STDBTRY,LITH,COIN,3.0V,225MA (battery) Vulcan Jet applicator 1126063 KIT, SEAL PACK, VULCANJET 1126064 KIT, SPRING, VULCANJET 1126065 KIT, HEATER BLOCK, VULCANJET...
  • Page 169: Technical Data

    9-11 Parts Technical Data Vulcan Jet Dispensing System Specifications Component Item Specification ‐45 - 75 _C (‐49 - 167 _F) System Transport temperature ‐45 - 75 _C (‐49 - 167 _F) Storage temperature 0 - 45 _C (32 - 113 _F)
  • Page 170: Applicator Dimensions

    9-12 Parts Applicator Dimensions Figure 9‐6 Vulcan Jet applicator dimensions, (in.) E 2021 Nordson Corporation Part 1126187_05...

Table of Contents