FireLake P77-3-SC30 Installation And Operator's Manual page 51

Incinerator
Table of Contents

Advertisement

Each operation takes 1 hour prior to temperature change.
If the unit has steam releasing from the refractory hold that temperature until the steam
SET TEMP
Hour 1
Hour 2
Hour 3
Hour 4
Hour 5
Hour 6
Hour 7
Hour 8
Hour 9
Hour 10
Hour 11
Hour 12
Hour 13
Hour 14
Hour 15
Hour 16
P77-3 SC30 Manual 9.27.2019
Curing Log
dissipates and then continue.
ACTUAL TEMP.
250° F
____________
250° F
____________
250° F
____________
250° F
____________
250° F
____________
250° F
____________
300° F
____________
400° F
____________
500° F
____________
600° F
____________
700° F
____________
800° F
____________
900° F
____________
1000° F
____________
1100° F
____________
1200° F
____________
Page 51