MODEL P77-3 SC30 SPECIFICATIONS
CHAMBLER CAPACITY:
CHAMBER VOLUME:
DOOR DIMENSION:
HEIGHT TO DOOR:
REFRACTORY:
JACKET MATERIAL:
HEIGHT TO TOP OF CHAMBER:
STACK:
STACK CAP:
SECONDARY CHAMBER
MODEL: OIL
MODEL: GAS
11/32" (350Kbtu) limiting orifices each lower burners
OPERATION:
INTERNAL DIMENSIONS:
OVERALL DIMENSIONS (APPROX.), INCLUDING
COUNTERBALANCE WEIGHTS, BURNER, STACK AND
STACK CAP
ELECTRICAL SERVICE:
WATER, FRESH (BURN CHAMBER SPRAY)
GAS SERVICE BASED ON MAX RATING OF THE THREE
BURNERS: (ACTUAL BURN IS LESS, FACTORY SETS
FLOW AND CONTROL TURNS THEM ON AND OFF)
FUEL OIL SET RATE OF THREE BURNERS: (ACTUAL
BURN IS LESS, CONTROL TURNS THEM ON AND OFF)
TOTAL WEIGHT:
PAD REQUIREMENTS (MINIMUM):
PAINT:
PATHOLOGICAL:
BURN RATE:
If on-site testing is required it is the responsibility of the purchaser and your Firelake dealer can assist in
the process. Outside installation is recommended with a minimum metal roof and three-sided metal
shelter, provided a minimum of four (4) foot clearance from any combustible material. Installations may
have special insurance or fire code requirements. Advise your insurance firm of the final placement.
Must be installed in accordance with local codes and ordinances, subject to governing regulatory
agencies. Consult local Fire Authorities for approval of roof penetrations and clearances.
P77-3 SC30 Manual 9.27.2019
Table 1: WASTE CHAMBER
2540 lbs. of waste at 33 lbs/cu ft
77 cubic feet
30" x 79"
54"
4", 2800
3/16" steel
55" varies
Table 2: STACK AND SECONDARY
(3) 18" Dia., 48" Long Steel Cast Lined
(1) 18" Diameter Stainless Steel
(1) Aluminized Steel with Refractory Lining
Table 3: BURNERS
Remote Standing Control Box with Temperature
Controls & Optional Recording
Table 4: GENERAL
32" W x 44" H x 83" L (less stack).
6.7 ft W x 13.5 ft L x 26 ft H
Standard-115 volt, 60hz, 30 amp, Also available --
220 volts, 50hz, 15 amp
Min. 60 psi at 0.8 gpm
2,800,000 BTUH (piping sized accordingly)
Natural Gas: 7" W.C. (with burners operating)
Liquid Propane: 11" W.C. (with burners operating)
Fuel Oil 3 burners x 3 gph = 9 GPH Burners pumps
move (not burn) approx 3x flow in two pipe operation.
18,500 lbs (approximate, varies with features)
6' W x 11' L x 6" Thick Concrete.
1200 degree primer 1200 degree paint
Table 5: CHARGING RATE
Approximate 1650 lbs. per charge at 33 lbs/cu ft of
typical pathological waste with a BTU/lb rating of
1000. Less pounds for volatile wastes. Chamber
may be recharged during burn with proper heat
resistant safety attire that protects from flash and heat
contact. Allow cool down for ash removal.
Will vary but may range up to 125lb./hr.
Page 4
f, 126 lbs/cubic feet
°
(3) Beckett SF Oil Burner W/ Flame Safety
(1) Midco 121 AND (2) Midco 83 w/safety controls