Safety cannot be overemphasized when charging the
incinerator. The following heat resistant garments should be
worn when charging or unloading:
Full length sleeves for arm protection.
Unprotected persons are not to be in area when charging.
1. Open door latches and remove any ashes before loading the incinerator.
Caution inside chamber could be hot or flames present.
2. Load incinerator. Start off with a minimum amount of waste (significantly
less than capacity) to gain experience with how your waste type burns.
Excess volatile material can overcome chamber with heat and cause
smoke or damage. Keep the waste away from the burner ports and
allow a gap of 4 inches along top of waste so flue gases can reach
stack or poor combustion and burner damage may occur.
5. Start incinerator by setting the digital timer for the desired burn time and
press ON. Experience dictates time.
6. Upper burner starts preheating and will climb in temperature to preset
value. Lower burners come on when preheat value is reached.
7. Lower burners may cycle on/off to save fuel and control heat.
burner is firing anytime timer is engaged and HI limit not tripped.
8. The incinerator will automatically shut off when the burn is completed.
9. Best outcome is white gray ash, color and texture varies by waste.
Operator opinion varies on burn time selected and degree of burn out
compared to fuel usage.
WARNING – Opening load door to access waste chamber while power is
on may lead to bodily harm. The burners are automatically controlled and
may come on unexpectedly. Flames from burning waste can also escape
from the chamber if the door is opened.
P77-3 SC30 Manual 9.27.2019
Operating Instructions
Insulated gloves.
Full length face shield.
Page 20
Upper

Advertisement

Table of Contents
loading

Table of Contents