View Power Module Status Information - Maipu MP3900X Series Installation Manual

Table of Contents

Advertisement

Power on and Run Router
Field
Software Image File

4.3.2 View Power Module Status Information

You can use the show system power command to view the relevant information of the
power supply used on the device, including the online information of the power, status
information, the swapping times statistics of the power module, and the error times
statistics during the swapping process.
Command: router#show system power
Display as follows:
System Power Information(Power 1 - ONLINE)
----------------------------------------------------------------
----------------------------------------------------------------
STATISTICS:
System Power Information(Power 2 - ONLINE)
----------------------------------------------------------------
----------------------------------------------------------------
STATISTICS:
Table 4-3 Key field description of the information displayed via show system power
Field
Power Name
Status
Description
Serial No
4-14
Type:
AD250-1S005E-B(V1)[0xf115]
Status:
Normal
Serial No.: B554174272900106
Description:
1 IN, 0 OUT, 0 IERR, 0 OERR
Type:
AD250-1S005E-B(V1)[0xf115]
Status:
Normal
Serial No.: B554174272900107
Description:
1 IN, 0 OUT, 0 IERR, 0 OERR
MP3900X Series Router Installation Manual
Description
Software mirror file name
Description
Power name, such as AD250-1S005E-B
Power status, such as Normal
The
power
description
provided by the device supplier, example:
<NULL> indicates that the description is
empty.
The serial number of the power, provided
by the device supplier, for example:
B554174272900106: the serial number of
Power 0