Download Print this page

Kinetico Powerline PRO Owner's Manual page 7

Timered and metered softeners

Advertisement

Normal Operation
Battery Backup (Uses a standard 9-Volt alkaline battery.)
Features of Battery Backup:
During power failures, the battery will maintain the time of day as long as the
battery has power. The display is turned off to conserve battery power during
this time. To confirm that the battery is working, press either button, and the
display will turn on for five (5) seconds.
• If power failure occurs while system is regenerating, the Kinetico Powerline
PRO Softener will motor to a shut off position to prevent constant flow to
drain. After power is restored, the Powerline PRO Softener will return and
finish the cycle where it left off prior to the power interruption.
• When used without battery back-up, during a power failure, the unit stops at
its current point in the regeneration position and then restarts at that point
when the power is restored. The time will be offset by the increment of time
the unit was without power, so it is necessary to reset the time of day on the
unit. No other system settings will be affected.
Starting Extra Regeneration Cycle
1. To Start Delayed Extra Cycle Example
- If Days Remaining Until Next Regeneration does not read '000,' press and hold the
Set/Change button for 3 seconds until the display reads '0000.'
- Regeneration cycle will initiate at the next designated regeneration time.
2. To start Immediate Extra Cycle
- With Gallons Remaining Until Next Regeneration at '0000'.
- Press and hold the Set/Change button.
- After 3 seconds, the regeneration cycle will begin.
3. To Fast Cycle thru regeneration
- Press and hold the Set/Change button for 3 seconds to advance to the next cycle step.
NOTE: Fast Cycle is not necessary unless you want to manually step through each
cycle step.
(Repeat until valve returns to the home display - time of day.)
Regeneration Cycle
(NOTE: These may need to be adjusted based on application.)
Step
Common Cycle Step Times
Step 1
Backwash
Step 2
Brine Draw
Step 3
Rapid Rinse
Step 4
Brine Refill
NOTE: Salt settings are pre-set at the factory for the maximum efficiency. Do not reduce
salt settings below 9 lbs. per cu. ft. as the water level in the brine tank will not reach
the grid plate.
[ 1]
First complete above step.
First complete above 2 steps.
Minutes
10
60
10
Varies by Model
Powerline PRO Softeners
7