3G-SDI ST2110 Over IP Gateway Converter Operation Manual Table of Contents Product Overview ..........4 Introduction ............ 4 Applications............ 6 Key Features ..........6 Specifications ..........7 Currently Supported Resolutions ....9 Managing the 500767-2110 ......10 Web interface ..........10 2.1.1 Configuring the 500767-2110 as a TX ..
60Hz uncompressed, in a point-to-point configuration. A second Media/Data port is provided and can be used to support ST-2022-7 Redundancy (Seamless Protection Switching). Thus a second MuxLab SFP module (model: 500970-UTP for UTP model, or 500970-MM for multimode fiber model) is pre-installed and included.
3G-SDI ST2110 Over IP Gateway Converter Operation Manual Figure 1c: Application Diagram with redundancy (with Fault) Applications The 500767-2110 is an ideal solution for SDI/IP hybrid environments. It allows broadcasters the ability to have a single IP infrastructure rather than two different ones. The 500767-2110 applications include commercial broadcast AV systems, news/sports/TV stations and movie networks.
3G-SDI ST2110 Over IP Gateway Converter Operation Manual • Supports SMPTE ST-2110 uncompressed SDI video up to 1080@ 60Hz • Supports SMPTE ST-2022-7 (Class D, supporting up to 150usec delay with no frame lose) AV signal Redundancy (Seamless Protection Switching) •...
Page 8
3G-SDI ST2110 Over IP Gateway Converter Operation Manual UTP: 100ft (30m), for model 500767-2110-UTP Latency Zero latency Compression None (uncompressed) Network Bandwidth Up to 3 Gbps Network Requirement 10G Ethernet LAN for AV transmission, and 1G LAN for 3 party...
3G-SDI ST2110 Over IP Gateway Converter Operation Manual Currently Supported Resolutions The following are the currently supported 500767-2110 video resolutions and frame rates. 1080p Color Color Depth Space 59.94 29.97 23.976 10 Bit YCbCr 422 1080i 720p Color Color Depth Space 59.94...
3G-SDI ST2110 Over IP Gateway Converter Operation Manual 2. Managing the 500767-2110 The 3G-SDI/ST2110 over IP Uncompressed Gateway can be managed through its Web interface and API. The system supports the ST-2110 protocol, and ST- 2022-7 Redundancy for critical applications. This section describes how to set up the 500767-2110 parameters using both the Web interface and the API.
3G-SDI ST2110 Over IP Gateway Converter Operation Manual 2.1.1 Configuring the 500767-2110 as a TX This section will describe how to configure the unit as a TX using the Web interface. Since the 500767-2110 is a Transceiver, it may be set as a Transmitter (TX) or Receiver (RX).
Page 13
3G-SDI ST2110 Over IP Gateway Converter Operation Manual Clicking on the Submit button will allow you to apply the new changes while clicking on Cancel will discard any changes. The following table describes the Media settings Settings Description SDP Video...
3G-SDI ST2110 Over IP Gateway Converter Operation Manual 2.1.3 TX System Info Page The System Info page displays general product information such model number, firmware and FPGA version, MAC and IP address, RS232 settings (for future use), etc. Figure 3: 500767-2110 TX System Info Page...
3G-SDI ST2110 Over IP Gateway Converter Operation Manual 2.1.5 TX Settings Page The Settings page allows the user to configure both the network and the RS232 settings (RS232 is for future use). Additionally, you may load the factory configuration by clicking on the Reset button while the Reboot button will reboot the unit.
Page 17
Firmware Upgrade The 500767-2110 comes with the firmware pre-installed, please check the MuxLab Web site to verify if a newer version is available. You may go to our support software/firmware page of our Web site to download the required files: https://muxlab.com/support?section=software-and-firmware...
Page 18
The user may perform a factory reset, by pressing on the “Reset” button. This will return the unit to the original MuxLab factory settings, and all user settings and data will be lost. Allow the process to complete without interruption.
3G-SDI ST2110 Over IP Gateway Converter Operation Manual 2.1.6 Configuring the 500767-2110 as a RX The following will explain how to configure the 500767-2110 as a RX from the Web interface. Since the 500767-2110 is a Transceiver, it may be set as a Transmitter (TX) or Receiver (RX).
Page 21
3G-SDI ST2110 Over IP Gateway Converter Operation Manual SDP input type settings are showed here Figure 7: 500767-2110 RX SDP Input Type Settings The following table shows the media settings of the 500767-2110 RX Settings Description • Input Type Manual: Audio, video and ANC data settings values are entered manually •...
3G-SDI ST2110 Over IP Gateway Converter Operation Manual • Media Settings ANC Data: Media information is set automatically • Manual: Media information is entered manually Media Force the RX to specific Video resolution [1920x1080p, 1920x1080i and 1280x720p] Color depth Force the RX to specific color depth value [8,10,12 and...
3G-SDI ST2110 Over IP Gateway Converter Operation Manual 2.1.10 RX Settings Page The Settings page of the RX allows you to configure both the network and the RS232 settings. Additionally, factory reset is possible by clicking on the Reset button. The Reboot button will reboot the unit. Note that performing a Reset will overwrite the unit settings and rest them to their factory default, while performing a Reboot will interrupt any active connection.
Page 26
Firmware Upgrade The 500767-2110-RX comes with the firmware pre-installed, please check the MuxLab Web site to verify if a newer version is available. You may go to our support software/firmware page of our Web site to download the required files: https://muxlab.com/support?section=software-and-firmware...
Page 27
The user may perform a factory reset, by pressing on the “Reset” button. This will return the unit to the original MuxLab factory settings, and all user settings and data will be lost. Allow the process to complete without interruption.
3G-SDI ST2110 Over IP Gateway Converter Operation Manual 2.2 500767-2110 API (NMOS and RestAPI) In addition to the Web interface, the 500767-2110 can also be managed through a RestAPI and NMOS management platforms. NMOS: The 500767-2110 supports NMOS IS-04 (for unit discovery) and IS-05 (for unit connectivity management).
Page 29
3G-SDI ST2110 Over IP Gateway Converter Operation Manual Enter [500767-2110-TX IP Address]/api/system for “System API” "ctrl_ip": "192.168.168.103", "nmosName": "500767-RX", "ctrl_gateway": "192.168.168.1", "fpgaBuilt": "Aug 16 2022 11:41", "isTx": 1, "name": "SDI/HDMI OverIP-767", "videoStatus": 1, "reset": 0, "sfp2_ip": "192.168.168.69", "isHdmi": 0, "ctrl_mac": "52:11:49:B2:EF:DE", "model": "500767",...
Page 30
3G-SDI ST2110 Over IP Gateway Converter Operation Manual Enter [500767-2110-TX IP Address]/api/video for “Video API” "width": 1920, "dest_ip2": "239.100.1.2", "dest_ip1": "239.100.1.1", "height": 1080, "local_port2": 48001, "payloadType": 96, "colorSpace": "YCbCr-4:2:2", "local_port1": 48000, "sessionID": "11206761062", "intlce": 3, "depth": 10, "dest_port2": 48001, "TTL": 32, "dest_port1": 48000,...
Page 31
3G-SDI ST2110 Over IP Gateway Converter Operation Manual "sample": "48000", "channels": 7, "chn0Remap": 0, "pktSize": "1ms", "chn4Remap": 4, "TTL": 32, "chnAlloc": 255, "dest_port2": 48011, "chnFilter": 255, "dest_port1": 48010, "chn5Remap": 5 Enter [500767-2110-TX IP Address]/api/sdp for “SDP API” "media": "video", "ip": "192.168.168.103", "port": 80,...
Page 32
3G-SDI ST2110 Over IP Gateway Converter Operation Manual "masterID": "b8-59-9f-ff-fe-7f-77-08", "isEnable": 1, "portState": "SLAVE", "mClockAccuracy": "0xfe", "errCode": 200, "offset": 18446744073709226000, "clockId": "52-11-49-ff-fe-b2-ef-de", "msg": "Begin to access data from server", "priority1": 254, "priority2": 254, "mClockClass": 248, "clockClass": 248, "offsetScaledLogVariance": "0xffff", "mPriority1": 128, "mPriority2": 128,...
Page 33
3G-SDI ST2110 Over IP Gateway Converter Operation Manual "PID": 445, "name": "muxManager" "PID": 444, "name": "muxBroker" "PID": 443, "name": "muxPoll" 500767-2110-RX RestAPI: The following screen shots show the RestAPI for the 500767-2110-RX (Receiver): The RestAPI commands can be accessed directly from a browser by entering the...
3G-SDI ST2110 Over IP Gateway Converter Operation Manual 3. Frequently Asked Questions The following FAQ section provides answers to the most frequent questions you may have regarding the configuration of the 500767-2110. What is the default IP address of the 500767-2110? By default the 500767-2110 is configured in DHCP mode.
Page 40
Check media parameters and ensure you are entering the right SDP information if using this input type. If it is still not working, email the SDP file to Muxlab support. 12G-SDI (4K/60) does not work on the 500767-2110? The maximum supported resolution on the 500767-2110 is 3G-SDI (1080p60).
Page 41
3G-SDI ST2110 Over IP Gateway Converter Operation Manual • Cabling layout. Please include the model of the SDI source and sink devices, cable length and type (e.g.: 20m of Cat 6a UTP, etc.). • Description of problem. • List of tests performed.
(RMA#) issued by its Customer Service Department, along with a dated proof of purchase. If this product is delivered to MuxLab by mail, you agree to assume risk of loss or damage in transit, to prepay shipping charges to the warranty service location, and to use the original shipping container or equivalent.
Page 43
All R.M.A.’s issued are subject to inspection by MuxLab, and will be returned to the customer if not properly packaged – units must be returned in the original container or equivalent. MuxLab will not accept any such product for repair without an authorization from its Technical Support department and without a return authorization number issued by the MuxLab Customer Service department.
Need help?
Do you have a question about the 3G-SDI ST2110 and is the answer not in the manual?
Questions and answers