Compliance - Pyronix ENFORCER RINS1706-1 Quick Reference Manual

Programming
Table of Contents

Advertisement

D. Compliance
Your panel is suitable for use in installations designed to meet the European requirements of Security Grade 2, Environmental Class 2.
When all parts are working normally, this equipment in combination with the modem (PSTN or GPRS) and suitable ARC equipment will meet the
requirements of Alarm Transmission System 2: ATS2 BS EN50131-1:2006+A1:2009. This is classified as Grade 2 Option B (from EN50131-1)
as per the table:
External arm/disarm readers meet the requirements of environmental class 4.
Notification Equipment
Remotely powered audible WD (siren)
Self-powered audible WD
Main ATS
Additional ATS
ATS = Alarm Transmission System. WD = Warning Device
All Wireless devices comply with the following EU requirements:
EMC Directive
2004/108/EC
Low Voltage Directive
2006/95/EC
R&TTE Directive
1999/5/EC
And meet the following standards where relevant:
EN 61000-6-3:2007+A1:2011
EN 50131-1:2006+A1:2009
EN 50130-4:2011
EN 60950-1:2006+A12:2011
EN 50131-5-3:2005+A1:2008
ETSI EN 301489-3:2000
ETSI EN 300 220
CEPT/ERC
Compliant operation is only guaranteed when installed and operated according to the relevant installation and user manuals.
Access Levels:
Level 1: Access by any person; for example the general public.
Level 2: User access by an operator; for example customers (systems users).
Level 3: User access by an engineer; for example alarm company personnel.
Level 4: User access by the manufacturer of the equipment.
Please note: Technical functions (e.g. gas, fire and flooding) are not security graded and fall outside the scope of EN50131-1 and EN50131-3
Compliance labelling should be removed or adjusted if non-compliant configurations are used
A
B
2
Optional
Optional
1
ATS 2
ATS 2
Optional
Optional
The following peripherals are certified:-
KX10DP-WE, MC1-WE, KF4-WE, MC1MINI-WE, KX15DC-WE,
KX25LR-WE, KX12DT-WE, KX10DTP-WE
KX12DQ-WE, MC2-WE, DELTABELL-WE, DIGI-1200
EMC. Generic emission standard. Residential, commercial and light industry
Alarm systems - Intrusion and hold up systems
Immunity requirements for components of fire, intruder and social alarm systems
Information technology equipment. Safety. General requirements
Grade 2. Interconnections for equipment using radio frequency techniques
EMC. Radio equipment. Part 3: Short range devices (SRD) 9kHz to 40 GHz
EMC. Receiver Class 1, Environmental Category 1
Recommendation 70-03 Annex 1
Grade 2 / Options
C
Optional
Optional
ATS 2
ATS 1
D
Optional
Optional
ATS 3
Optional