Summary of Contents for Pyronix ENFORCER RINS1706-1
Page 1
EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008 Security Grade 2 Environmental Class II Software Version >10 INTERNAL SIREN WARNING The Enforcer 32-WE control panel contains a 100dBA siren. Please be aware of this during installation. Programming Quick Reference Manual Wireless Alarm System RINS1706-1...
A. Operating the Enforcer 32-WE Default Master Manager Code: 1234 Default Engineer Code: 9999 Arming/Disarming Methods: There are four different devices that may be used in the process of arming/disarming the alarm system; these are the keypad, tag reader, keyfob and the app (on an Android or iOS mobile device). Button Operations a = Exit engineer menu/Selects Area A b = Moves backwards to the previous main menu item / Selects Area B...
B. Entering the Engineer Menu E n t e r Y o u r C o d e D A T E & T I M E ? E n f o r c e r 3 2 W E Default Engineer Code: 9999 Engineer [ * * * * ]...
3. Engineer Menu: Program Inputs I n p u t [ 0 1 ] I n p u t T y p e [ 0 7 ] I n p u t I n A r e a C o m m o n I n p u t P R O G R A M I N P U T S ? I n p u t 0 1 E n t r y D e l a y 1...
Program Output Types [0000] Not Used [0031] Entry [0063] Test UK STU [0001] Fire [0032] Exit [0064] Pre RM Service [0002] PA Any [0033] Entry/Exit [0065] Input Fault [0003] Burglary Any [0034] Lights [0066] ATE Pin not used [0004] Final Arm All [0035] Follow Input [0067] Follow Chime [0005] Open After Alarm...
6. Engineer Menu: Install Keypads/Readers O p t i o n s : D e v i c e A d d r e s s D e v i c e T y p e I N S T A L L K E Y P A D S / [ 0 ] K e y p a d [ 0 ] [ 1 ] R e a d e r...
7. Engineer Menu: Program Timers* A E n t r y T i m e 1 A E n t r y T i m e 2 A E x i t T i m e A B e l l T i m e P R O G R A M T I M E R S ? R e p e a t f o r A r e a s B , S e c o n d s...
8. Engineer Menu: Change Codes* C H A N G E C O D E S ? C h a n g e D u r e s s / E m p t y [ 0 1 E n t e r U s e r C o d e U s e r T y p e U s e r I n A r e a G u a r d C o d e s ?
10. Engineer Menu: System Options Engineer Menu: System Options->Options S Y S T E M O p t i o n s ? A r m W i t h T a m p e r A r m i f M o d e m F l t A r m w i t h T e c / F l t A r m F a i l = A l a r m...
Engineer Nenu: System Options->System Displays & Exit Options S Y S T E M O p t i o n s ? F o r ' O p t i o n s ' , s e e t h e p r e v i o u s p a g e . O P T I O N S ? A r e a A T e x t R e p e a t f o r...
11. Engineer Menu: Review Logs R E V I E W L O G S ? P a n e l L o g ? 0 1 / 0 1 0 0 : 1 1 : 4 4 R e p e a t f o r a l l S t a r t o f L o g A l a r m S i l e n c e d E v e n t s...
12. Engineer Menu: Engineer Tests W a l k T e s t ? W a l k T e s t A r e a s W a l k T e s t I n p u t s W a l k t o a c t i v a t e W a l k T e s t I n p u t s E N G I N E E R T E S T S ?
13. Engineer Menu: Diagnostics Engineer Menu: Diagnostics->Wireless Devices D I A G N O S T I C S ? W i r e l e s s V i e w I n p u t s ? C C C O C C C - - - - - - - - - I n p u t R e a d i n g s : [ C ] C l o s e , [ O ] O p e n , [ T ] T a m p e r , [ - ] N o t l e a r n t , [ F ] F a u l t D e v i c e s ?
Engineer Menu: Diagnostics->Wired Devices D I A G N O S T I C S ? W i r e l e s s For 'Wireless Devices', D e v i c e s ? see page : 18 I n p u t R e a d i n g s : [ C ] C l o s e , [ O ] O p e n , [ T ] T a m p e r , [ - ] N o t l e a r n t , [ F ] F a u l t W i r e d D e v i c e s ? V i e w I n p u t s ?
Engineer Menu: Diagnostics->Communications (DIGI-GPRS) The following strings will be displayed if a GPRS Modem is connected to the Enforcer 32-WE D I A G N O S T I C S ? W i r e l e s s For 'Wireless Devices', D e v i c e s ? see page : 18...
Engineering Menu: Diagnostics->Communications (PSTN Modem – DIGI-1200) The following strings will be displayed if a PSTN Modem is connected to the Enforcer 32-WE D I A G N O S T I C S ? W i r e l e s s D e v i c e s ? For 'Wireless Devices', see page : 18...
Engineer Menu: Diagnostics->Communications (DIGI-LAN) The following strings will be displayed if a LAN Module is connected to the Enforcer 32-WE D I A G N O S T I C S ? W i r e l e s s For 'Wireless Devices', D e v i c e s ? see page : 18...
14. Engineer Menu: Engineer Restore Options E N G I N E E R R e s t o r e B u r g l a r y R e s t o r e P A R e s t o r e T a m p e r R e s t o r e S o a k R e s t o r e F a u l t s R E S T O R E O P T I O N S ?
A p p S e t - U p ? For 'App Set-up', App Set-Up see page 25. This function enables or disables communication with the Pyronix App/Cloud. Refer to the User Manual for more information. Network Set-Up Programs the DIGI-GPRS or DIGI-LAN or DIGI-1200 to the Enforcer system.
Cloud Password: A password is required to allow remote access to the Pyronix Cloud. App Password: A password is required to allow remote access to the Pyronix Home Control+ App. NOTE: When creating passwords, please ensure that the password uses a variety of upper case, lower case, numbers and symbols to ensure the best security possible.
Page 26
15.1.2 Engineer Menu: Communications-> App Set Up High Security S e c u r i t y A p p S e t - U p ? E n a b l e A p p S y s t e m I D : C l o u d P a s s w o r d : H i g h [ 1 ]...
Engineer Menu: Communications->Network Setup G P R S A P N ? N e t w o r k S e t - U p ? P r o g r a m G P R S ? G P R S U s e r I D ? G P R S P a s s w o r d ? P a n e l I P A d d r e s s P a n l S u b n e t M a s k...
Engineer Menu: Communications->ARC Signalling 15.3.1 Engineer Menu: Communications->ARC Signalling (Security Standard) V a l i d A r e a s A R C S i g n a l l i n g ? A R C D e t a i l s : F o r m a t [ 1 4 9 ] [ 1 ]...
Page 29
15.3.2 Engineer Menu: Communications->ARC Signalling (Security High) A R C S i g n a l l i n g ? V a l i d A r e a s A R C D e t a i l s : F o r m a t [ 1 4 9 ] [ 1 ]...
Engineer Menu: Communications->User SMS Signalling U s e r S M S S M S D e t a i l s : U s e r M o b i l e : V a l i d A r e a s R e d i a l s T i m e O u t S i g n a l l i n g ?
Engineer Menu: Communications->Advanced Communications S e n d A l a r m s A d v a n c e d S e n d E v e n t s U D L ? M o d e m T e l N o S e n d F a u l t s S e n d O p e n / C l o s e [ 0 ]...
16. Engineer Menu: Alarm Responses A r e a A s t a r t a t A r e a A s t o p a t R e p e a t f o r B , C , D R e p e a t f o r B , C , D F i r e s t a r t a t A L A R M...
17. Engineer Menu: Options Up/Downloading* Engineer Menu: Options Up/Downloading->Download by Cloud 17.1.1 Engineer Menu: Options Up/Downloading->Download by Cloud (Standard Security) D o w n l o a d b y S y s t e m I D : S e c u r i t y S y s t e m P a s s w o r d : P o l l S e r v e r ? O P T I O N S U P / D O W N -...
Page 34
17.1.2 Engineer Menu: Options Up/Downloading->Download by Cloud (High Security) D o w n l o a d b y S y s t e m I D : S e c u r i t y O P T I O N S U P / D O W N - L O A D I N G ? C l o u d [ 6 ]...
Engineer Menu: Options Up/Downloading->Download by RS-232 D o w n l o a d b y U D L P a s s w o r d S i t e N a m e U D L P r i o r i t y O P T I O N S U P / D O W N - R S 2 3 2 [ 2 ]...
Engineer Menu: Options Up/Downloading->Download by PSTN D o w n l o a d b y D i a l M o d e O p t i o n D i a l I n O p t i o n s N u m b e r o f R i n g s O P T I O N S U P / D O W N - P S T N...
18. Engineer Menu: PC Connect Menu P C C O N N E C T M E N U ? S e l e c t P C t o S e l e c t O p e r a t i o n C a l l i n g R e m o t e P C d i a l [ 1 ]...
20. Engineer Menu: Factory Default D e f a u l t C o d e F A C T O R Y D E F A U L T ? P l e a s e W a i t F a c t o r y D e f a u l t C o m p l e t e ! D e f a u l t C o d e s :...
C. Stand Alone Wired Keypad P r e s s a n d H o l d D key for 5 seconds NOTE: This menu is dedicated to the keypad itself. This menu is mostly used for the following features: Keypad Address, Keyclick Volume, and Backlight Force. NOTE: The keypad on the Enforcer must always be programmed to '00' K E Y P A D C O D E A D D R E S S...
D. Compliance Your panel is suitable for use in installations designed to meet the European requirements of Security Grade 2, Environmental Class 2. When all parts are working normally, this equipment in combination with the modem (PSTN or GPRS) and suitable ARC equipment will meet the requirements of Alarm Transmission System 2: ATS2 BS EN50131-1:2006+A1:2009.
21. Event Types For ARC signalling and SMS signalling, there are four options/defaults for event types. Choose Default 1, 2 or 3 according to requirements – or choose ‘custom’ and select each individual option manually: Custom Default 1 Default 2 Default 3 ...
Need help?
Do you have a question about the ENFORCER RINS1706-1 and is the answer not in the manual?