Performance Specifications - Mitsubishi CL2XY16-DTP1C5V User Manual

Table of Contents

Advertisement

2.2 Performance specifications

The performance specifications for the remote I/O module are shown in the
following table.
Type
Item
Input specifications
Number of inputs
Isolation method
Rated load voltage
Rated input current
Max. simultaneous ON
input points
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Protect function
Response
time setting
Response
OFF
TYP.
time
ON MAX.
ON
TYP.
OFF
MAX.
Input method
Common wiring method
Number of stations
occupied
Voltage
Module
Current
power
consumption
supply
Current on
startup
Noise durability
Withstand voltage
Insulation resistance
Protection class
Weight
I/O part connection
method
Module installation
method
8 points
Photocoupler isolation
24V DC (Common with the
module power supply)
Approx. 4mA
100%
19V or more/3mA or more
11V or lower/1.7mA or lower
5.6k
-
0.5ms
1.5ms
(High speed
(Standard
response type)
type)
0.05ms
0.1ms
1.5ms
0.2ms
0.5ms
1.5ms
Positive common
8 points/1 common (sensor
connector 3-wire type)
In 4-point mode: Occupies 2 stations
In 8 or 16-point mode: Occupies 1 station
24V DC (-15 to +20%) (ripple ratio : within 5%)
50mA or lower (When 24V DC and all point is on)
DC type noise voltage 500Vp-p, noise width 1µs,
noise carrier frequency 25 to 60Hz (noise simulator condition)
First transient/noise burst IEC 61000-4-4 : 1kV
500V AC for 1 minute between primary (external DC terminal) and
10M or more between primary (external DC terminal) and secondary
(internal circuit) when measured with a 500V DC insulation resistance tester
Open sensor connector (e-CON) 16
(Connector plugs are sold separately (compatible wire size: 0.08 to 0.5
2
mm
, depending on the connector plug used). Refer to the CC-Link/LT
DIN rail installation, Can be installed in six directions
CL2XY16-DTP1C5V
Output specifications
Number of outputs
Isolation method
Rated load
voltage
Max. load current
Max. inrush
current
Leakage current
at OFF
Voltage drop at
ON
Output method
Protect function
OFF
1.5ms
-
(Standard
type)
-
ON
OFF
Surge
suppression
Common wiring
method
70mA or lower (24V DC)
secondary (internal circuit)
IP2X
0.08kg
Catalog.)
2
8 points
Photocoupler isolation
24V DC (Common with
the module power
supply)
0.1A/point 0.8A/1
common
0.7A 10ms or lower
0.1mA or lower
0.3V or lower (TYP.)
0.1A, 0.6V or lower
(MAX.) 0.1A
Sink type
Overload protection
function ,Overheat
protection function
0.5ms or lower
ON
0.5ms or lower
(Resistive load)
Zener diode
8 points/1 common
(sensor connector
2-wire type)