8 Test run

8.1 Test run instructions

You should perform the Test Run for at least
30 minutes.
1. Connect power to the unit.
2. Press the ON/OFF button on the remote
controller to turn it on.
3. Press the MODE button to scroll through the
following functions, one at a time:
• COOL – Select lowest possible temperature
• HEAT – Select highest possible temperature
4. Let each function run for 5 minutes, and
perform the following checks:
List of Checks to Perform
No electrical leakage
Unit is properly grounded
All electrical terminals properly
covered
Indoor and outdoor units are
solidly installed
All pipe connection points do not
leak
Water drains properly from drain
hose
All piping is properly insulated
Unit performs COOL function
properly
Unit performs HEAT function
properly
Indoor
unit
louvers
properly
Indoor unit responds to remote
controller
42 / 116 EN
PASS/FAIL
Outdoor
Indoor
(2):
(2):
rotate
During operation, the pressure
of the refrigerant circuit will
increase. This may reveal leaks
C
that were not present during
your initial leak check. Take time
during the Test Run to double-
check that all refrigerant pipe
connection points do not have
leaks. Refer to Gas Leak Check
section for instructions.
5. After the Test Run is successfully completed,
and you confirm that all checks points in List
of Checks to Perform have PASSED, do the
following:
– Using remote control, return unit to normal
operating temperature.
– Using insulation tape, wrap the indoor
refrigerant pipe connections that you
left uncovered during the indoor unit
installation process.
If ambient temperature is below 17°c (62°f)
You can't use the remote controller to turn on
the cool function when the ambient temperature
is below 17°c. In this instance, you can use the
manual control button to test the cool function.
1. lift the front panel of the indoor unit, and raise it
until it clicks in place.
2. The MANUAL CONTROL button is located on
the right-hand side of the unit. Press it 2 times
to select the COOL function.
3. Perform Test Run as normal.
Split Type Air Conditioner / User Manual
Manual control button
Manual control button