1 Safety Precautions
4. For equipment that contains
fluorinated greenhouse gases
in quantities of 5 tonnes of
CO2 equivalent or more, but
of less than 50 tonnes of
CO2 equivalent, If the system
has a leak-detection system
installed, it must be checked
for leaks at least every
24 months.
5. When the unit is checked for
leaks, proper record-keeping
of all checks is strongly
recommended.
Warning for Using R32/R290
Refrigerant
When flammable refrigerant
are employed, appliance shall
be stored in a well -ventilated
area where the room size
corresponds to the room area
as specific for operation.
For R32 frigerant models:
Appliance shall be installed,
operated and stored in a room
with a floor area larger than
4m
.
2
For R290 refrigerant models,
appliance shall be installed,
10 / 116 EN
operated and stored in a room
with a floor area larger than:
<=9000Btu/h units: 13m
>9000Btu/h and
<=12000Btu/h units: 17m
>12000Btu/h and
<=18000Btu/h units: 26m
>18000Btu/h and
<=24000Btu/h units: 35m
R e u s a b l e
connectors and flared joints
are not allowed indoors. (EN
Standard Requirements).
Mechanical connectors used
indoors shall have a rate of
not more than 3g/year at 25%
of the maximum allowable
pressure. When mechanical
connectors are reused indoors,
sealing parts shall be renewed.
When flared joints are reused
indoors, the flare part shall be
re-fabricated. (UL Standard
Requirements)
When mechanical connectors
are reused indoors, sealing parts
shall be renewed. When flared
joints are reused indoors, the
Split Type Air Conditioner / User Manual