4 Installation
Make sure that the drain hose
C
is at the bottom of the bundle.
Putting the drain hose at the
top of the bundle can cause the
drain pan to overflow, which can
lead to fire or water damage.
CAUTION! While bundling these
A
items together, do not intertwine
or cross the signal cable with any
other wiring.
2. Using adhesive vinyl tape, attach the drain hose
to the underside of the refrigerant pipes.
3. Using insulation tape, wrap the signal wire,
refrigerant pipes, and drain hose tightly together.
Double-check that all items are bundled.
CAUTION! When wrapping the
bundle, keep the ends of the
piping unwrapped. You need to
A
access them to test for leaks at
the end of the installation process
(refer to Electrical Checks and
Leak Checks section of this
manual).
Step 8: Mount indoor unit
If you installed new connective piping to the
outdoor unit, do the following:
1. If you have already passed the refrigerant piping
through the hole in the wall, proceed to Step 4.
2. Otherwise, double-check that the ends of the
refrigerant pipes are sealed to prevent dirt or
foreign materials from entering the pipes.
3. Slowly pass the wrapped bundle of refrigerant
pipes, drain hose, and signal wire through the
hole in the wall.
28 / 116 EN
4. Hook the top of the indoor unit on the upper
hook of the mounting plate.
5. Check that unit is hooked firmly on mounting
by applying slight pressure to the left and right-
hand sides of the unit. The unit should not jiggle
or shift.
6. Using even pressure, push down on the bottom
half of the unit. Keep pushing down until the
unit snaps onto the hooks along the bottom of
the mounting plate.
7. Again, check that the unit is firmly mounted by
applying slight pressure to the left and the right-
hand sides of the unit.
If refrigerant piping is already embedded in the
wall, do the following:
1. Hook the top of the indoor unit on the upper
hook of the mounting plate.
2. Use a bracket or wedge to prop up the unit,
giving you enough room to connect the
refrigerant piping, signal cable, and drain hose.
3. Connect drain hose and refrigerant piping (refer
to Refrigerant Piping Connection section of this
manual for instructions).
4. Keep pipe connection point exposed to perform
the leak test (refer to Electrical Checks and
Leak Checks section of this manual).
5. After the leak test, wrap the connection point
with insulation tape.
6. Remove the bracket or wedge that is propping
up the unit.
Split Type Air Conditioner / User Manual