9-12 Keyboard dialing
Response: Incoming data call connection fails because of mismatch in
terminal parameters. A terminal beep also sounds to alert the user.
Keyboard dialing exceptions
Table 9-1 contains exceptions to normal KBD operating procedures
including suggested corrective actions. (The Break key refers to the
Control-Z sequence.
Table 9-1xxx
KBD operation exceptions
Problem
Attempt to activate
unassigned feature failed, or
call attempt failed.
Incoming or outgoing call
failed because of
communications
incompatibility.
Dialing aborted by pressing
Break key (Control Z).
User pressed CR only when
prompted for number input.
User input errors committed.
DN input times-out, or RAG
activation times-out.
RAG recall timeout occurs.
Extended Hayes keyboard dialing
Prompt Message Characteristics
Prompt messages are either a numeric code or word code, depending upon
the value of the V parameter (see Hayes Keyboard Dialing Parameters).
Hayes KBD prompts are listed in Table 9-2.
555-4001-112 Standard 05.01 March 1995
Screen Display
NO SYSTEM RESPONSE.
RESELECT:
INCOMPATIBLE
COMMUNICATIONS
PARAMETER. CALL
RELEASED.
ABORTED
ABORTED
INVALID
COMMAND/ENTRY.
REENTER:
CALL RELEASED
RING AGAIN
CANCELLED
Corrective Action
Key in a new selection from
the appropriate menu.
Reenter appropriate selection
or proper DN.
No corrective action
necessary. Main Menu is
redisplayed.
No corrective action
necessary. Main Menu is
redisplayed.
Reenter appropriate selection
or proper DN.
No corrective action
necessary. Main Menu is
redisplayed.
No corrective action
necessary. Main Menu is
redisplayed.