Download Print this page

Installation Instructions - CellarPro 6200VS-ECX Owner's Manual

Self contained wine cellar cooling unit

Advertisement

   
T E S T T H E U N I T B E F O R E I N S T A L L I N G I T
Please note:
protect its internal components.
Cut a hole in the wall that is 1/4 inch larger than the dimensions
(W x H) of the cooling unit, and create a frame to support the rear of
the cooling unit. The rear of the cooling unit should be supported by the wall
through which it is installed. Horizontal 2 x 4 inch braces should be installed
between the studs below and above the cooling unit. If the studs in the wall
must be cut to accommodate the width of the cooling unit, vertical braces also
should be installed on either side of the cooling unit.
 
 
 
 
 
II. Installation Instructions 
1. Remove the unit from the box.
SAVE THE BOX AND PACKING MATERIALS.
2. Plug in the power cord and let the unit run on a hard, flat surface for
no more than 5 minutes .
3. Check to make sure that both fans (one in the front and one at the rear
of the cooling unit) are blowing.
4. Check that the cooling unit is discharging cold air from the front
(it should be approximately 10 - 12° F colder than the temperature
on the digital display)
The cooling system is programmed with a 3-Minute Delay at Startup to
6200 / 8200 Frame and Cut-Out Diagram
 
10
 
 
V3.15.22

Advertisement

loading

This manual is also suitable for:

8200vs-ecx6200vs-ecc8200vs-ecc