Hydromatic SKV50M1 Installation And Service Manual

Hydromatic SKV50M1 Installation And Service Manual

Submersible sewage ejector pump

Advertisement

Quick Links

SKV50
Submersible Sewage
Ejector Pump
NOTE! To the installer: Please make sure you provide
this manual to the owner of the pumping equipment or to
the responsible party who maintains the system.
Pump Installation and Service Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SKV50M1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hydromatic SKV50M1

  • Page 1 Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system.
  • Page 2: General Information

    Attention: Do not install pump in location properly when needed. classified as hazardous per This manual contains important 7. Hydromatic check valve N.E.C., ANSI/NFPA 70 - 1999. information for the safe use of should be installed in discharge this product.
  • Page 3: Pump Servicing

    Electrical shock may occur. Hydromatic service center pumping waterlike liquids or distributor. (temperature to 140° F). 1. Before removing pump from The SKV50 will pump solid Pump the sump, check to be sure the materials up to 2"...
  • Page 4 applied to shaft at assembly, so existing stator, or vice versa.) Pump to remove impeller it will be Reassemble the stator (12) to Servicing necessary to break this seal. the seal plate (10) with the four This is why the plastic or long cap screws (16).
  • Page 5: Pump Troubleshooting

    Pump Troubleshooting Servicing should be performed only by an authorized Hydromatic service center. Warning: Always disconnect the pump from power source before handling or making any adjustments.
  • Page 6 1. Pump may be air locked. Start run slow, resulting in motor Hydromatic pumps have a and stop several times by overload. Clear impeller. small air vent hole in the plugging and unplugging cord.
  • Page 7: Parts List

    SKV50 Parts List Refer to an authorized Hydromatic service center to order parts. Ref. No. Part No. Description Qty. Ref. No. Part No. Description Qty. 60-000-5 Handle 14623-020-1 Cord Assy. *16-3, 20', 115V 4580-001-1 Drive Screw 14623-210-1 Cord Assy. *16-3, 10', 230V...
  • Page 8: Limited Warranty

    Your only remedy, and HYDROMATIC’s only duty, is that HYDROMATIC repair or replace defective products (at HYDROMATIC’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired.

This manual is also suitable for:

Skv50

Table of Contents